Lucene search
+L

167 matches found

Positive Technologies
Positive Technologies
•added 2021/03/10 12:00 a.m.•6 views

PT-2021-9252

Name of the Vulnerable Software and Affected Versions Qualcomm Snapdragon affected versions not specified Description The issue is related to a use after free problem that occurs when importing a DMA buffer using the CPU address of the buffer. This happens because the attachment is not properly...

7.8CVSS0.0022EPSS
SaveExploits0References8
osv_cve
osv_cve
•added 2020/06/11 3:15 p.m.•16 views

CVE-2020-0203

In freeIsolatedUidLocked of ProcessList.java, there is a possible UID reuse due to improper cleanup. This could lead to local escalation of privilege between constrained processes with no additional execution privileges needed. User interaction is not needed for exploitation.Product:...

7.8CVSS5.9AI score0.00246EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/06/11 2:14 p.m.•40 views

CVE-2020-0203

In freeIsolatedUidLocked of ProcessList.java, there is a possible UID reuse due to improper cleanup. This could lead to local escalation of privilege between constrained processes with no additional execution privileges needed. User interaction is not needed for exploitation.Product:...

8.4AI score0.00246EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2020/04/23 12:00 a.m.•27 views

ClamAV DoS

The vulnerability of the ClamAV antivirus software is related to improper cleaning or release of resources. Exploiting this vulnerability can allow a hacker to cause a service failure by sending specially crafted messages to the vulnerable system...

5.3CVSS7.4AI score0.0218EPSS
SaveExploits0References8Affected Software8
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/04/30 12:00 a.m.•8 views

CVE-2017-9657: Improper Cleanup on Thrown Exception

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor,...

6.5CVSS6.5AI score0.00769EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/04/30 12:00 a.m.•9 views

CVE-2017-9658: Improper Handling of Exceptional Conditions

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this...

6.5CVSS6.5AI score0.0081EPSS
SaveExploits0References3
ICS
ICS
•added 2017/09/12 12:00 a.m.•77 views

ICSMA-17-255-01_Philips' IntelliView MX40 Patient Worn Monitor (WLAN) Vulnerabilities

OVERVIEW Philips has identified two vulnerabilities in Philips’ IntelliView MX40 Patient Worn Monitor for use with wireless local area networks WLANs. Philips has produced a software update that fixes one of the identified vulnerabilities and provides mitigations for the other vulnerability...

6.9AI score
SaveExploits0References2