Lucene search
+L

4211 matches found

Positive Technologies
Positive Technologies
added 2021/06/16 12:0 a.m.10 views

PT-2021-7873 · Sap · Sap Netweaver Abap Server +1

Name of the Vulnerable Software and Affected Versions: SAP NetWeaver ABAP Server and ABAP Platform versions 700, 701, 702, 731, 740, 750, 751, 752, 753, 754, 755, 804 Description: The issue is related to improper authentication due to the inconsistent and undistinguished format of internal and...

9.8CVSS8.5AI score0.0132EPSS
SaveExploits0References9
Japan Vulnerability Notes
Japan Vulnerability Notes
added 2021/06/14 6:10 a.m.5 views

Multiple vulnerabilities in GROWI

Overview GROWI provided by WESEEK, Inc. contains multiple vulnerabilities listed below. NoSQL injection CWE-943 - CVE-2021-20736 Improper authentication CWE-287 - CVE-2021-20737 Impact The expected impact depends on each vulnerability, but it may be affected as follows. A user who can access the...

9.1CVSS7.1AI score0.01307EPSS
SaveExploits0References8
Japan Vulnerability Notes
Japan Vulnerability Notes
added 2021/06/14 12:0 a.m.78 views

JVN#95457785: Multiple vulnerabilities in GROWI

GROWI provided by WESEEK, Inc. contains multiple vulnerabilities listed below. NoSQL injection CWE-943 - CVE-2021-20736 Version| Vector| Score ---|---|--- CVSS v3| CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L| Base Score: 7.3 CVSS v2| AV:N/AC:L/Au:N/C:P/I:P/A:P| Base Score: 7.5 Improper...

9.1CVSS7.7AI score0.01307EPSS
SaveExploits0
OSV
OSV
added 2021/06/11 4:15 p.m.9 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.3CVSS6.1AI score0.01874EPSS
SaveExploits0References2
Prion
Prion
added 2021/06/11 4:15 p.m.16 views

Authentication flaw

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5CVSS5.3AI score0.01874EPSS
SaveExploits0References1Affected Software4
ATTACKERKB
ATTACKERKB
added 2021/06/11 4:15 p.m.6 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.3CVSS6AI score0.01874EPSS
SaveExploits0References3
CVE
CVE
added 2021/06/11 3:40 p.m.66 views

CVE-2021-22764

CVE-2021-22764 is an improper authentication vulnerability affecting Schneider Electric PowerLogic PM55xx, PM8ECC, EGX100, and EGX300. The issue can cause loss of connectivity to the device over Modbus TCP when an attacker sends a specially crafted HTTP request. Public documents identify the affe...

5.3CVSS5.3AI score0.01874EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
added 2021/06/11 3:40 p.m.6 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

6.1AI score0.01874EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/06/11 3:40 p.m.33 views

CVE-2021-22764

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.6AI score0.01874EPSS
SaveExploits0References1
OSV
OSV
added 2021/06/11 3:15 p.m.7 views

CVE-2021-25424

Improper authentication vulnerability in Tizen bluetooth-frwk prior to Firmware update JUN-2021 Release allows bluetooth attacker to take over the user's bluetooth device without user awareness...

8.8CVSS5.8AI score0.00438EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2021/06/11 12:0 a.m.17 views

PT-2021-15202

Name of the Vulnerable Software and Affected Versions PowerLogic PM55xx affected versions not specified PowerLogic PM8ECC affected versions not specified PowerLogic EGX100 affected versions not specified PowerLogic EGX300 affected versions not specified Description A CWE-287: Improper...

5.3CVSS6.1AI score0.01874EPSS
SaveExploits0References6
NVD
NVD
added 2021/06/09 7:15 p.m.21 views

CVE-2020-24514

Improper authentication in some IntelR RealSenseTM IDs may allow an unauthenticated user to potentially enable escalation of privilege via physical access...

6.8CVSS0.00267EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/06/09 7:15 p.m.3 views

CVE-2020-24514

Improper authentication in some IntelR RealSenseTM IDs may allow an unauthenticated user to potentially enable escalation of privilege via physical access...

6.8CVSS5.2AI score0.00267EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2021/06/09 6:48 p.m.26 views

CVE-2020-24514

Improper authentication in some IntelR RealSenseTM IDs may allow an unauthenticated user to potentially enable escalation of privilege via physical access...

7AI score0.00267EPSS
SaveExploits0References1
OSV
OSV
added 2021/06/09 3:15 p.m.10 views

CVE-2020-15381

Brocade SANnav before version 2.1.1 contains an Improper Authentication vulnerability that allows cleartext transmission of authentication credentials of the jmx server...

7.5CVSS7.1AI score0.01033EPSS
SaveExploits0References1
NVD
NVD
added 2021/06/09 3:15 p.m.35 views

CVE-2020-15381

Brocade SANnav before version 2.1.1 contains an Improper Authentication vulnerability that allows cleartext transmission of authentication credentials of the jmx server...

7.5CVSS0.01033EPSS
SaveExploits0References1
Prion
Prion
added 2021/06/09 3:15 p.m.26 views

Authentication flaw

Brocade SANnav before version 2.1.1 contains an Improper Authentication vulnerability that allows cleartext transmission of authentication credentials of the jmx server...

5CVSS7.8AI score0.01033EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/06/09 2:32 p.m.59 views

CVE-2020-15381

CVE-2020-15381 affects Brocade SANnav before version 2.1.1, where an Improper Authentication vulnerability allows cleartext transmission of authentication credentials for the JMX server. The issue is documented across multiple sources (NVD, Red Hat, Broadcom advisory BSA-2021-1483) and is specifi...

7.5CVSS7.7AI score0.01033EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2021/06/09 2:32 p.m.34 views

CVE-2020-15381

Brocade SANnav before version 2.1.1 contains an Improper Authentication vulnerability that allows cleartext transmission of authentication credentials of the jmx server...

7.8AI score0.01033EPSS
SaveExploits0References1
OSV
OSV
added 2021/06/09 12:15 p.m.7 views

CVE-2021-33842

Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...

8.8CVSS7.3AI score0.00428EPSS
SaveExploits0References1
Rows per page
Query Builder