8 matches found
PT-2026-116155
šØ CVE-2026-108576 A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function process ping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was...
Tozed ZLT X300 6.01.3 IPPingDiagnostics Command Injection
Tozed ZLT X300 versions 6.01.0 through 6.01.3 contain an OS command injection vulnerability in the IPPingDiagnostics handler through the Host argument...
CVE-2026-108576
A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function processping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about th...
CVE-2026-108576 TOZED X300 IPPingDiagnostics process_ping os command injection
A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function processping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about th...
CVE-2026-108576
A critical OS command injection vulnerability exists in TOZED X300 (versions up to 6.01.3 ). The flaw is located within the process_ping function of the IPPingDiagnostics Handler component. An attacker can achieve remote code execution by manipulating the Host argument. The impact is severe, with...
EUVD-2026-96983
A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function processping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about th...
CVE-2026-108576: Improper Neutralization of Special Elements used in an OS Command
A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function processping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about th...
TOZED X300 Command Injection Vulnerability
The TOZED X300 versions 6.01.3 and earlier have a command injection vulnerability. This vulnerability stems from the incorrect handling of the Host parameter in the processping function of the IPPingDiagnostics Handler component, which may lead to remote OS command injection...