BDU FSTEC
BDU FSTEC
•added 2026/01/28 12:00 a.m.•20 views

The vulnerability of the Real-Time Streaming Protocol (RTSP) implementation of Vivotek IP7137 software, which allows a intruder to gain unauthorized access to protected information.

The vulnerability of the Real-Time Streaming Protocol RTSP implementation of Vivotek IP7137 software-based IP cameras is related to the absence of authentication for a critical function. Exploiting this vulnerability could allow an attacker operating remotely to gain unauthorized access to...

7.8CVSS5.8AI score0.00416EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2026/01/28 12:00 a.m.•16 views

The vulnerability of Vivotek IP7137 micro-programmed IP cameras, which stems from the use of a default password, allows intruders to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of Vivotek IP7137 micro-programmed camera software is related to the use of a default password. Exploiting this vulnerability could allow an attacker to compromise the confidentiality, integrity, and accessibility of the protected information...

10CVSS5.8AI score0.00383EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2026/01/28 12:00 a.m.•13 views

The vulnerability of Vivotek IP7137 micro-programmed IP cameras arises from incorrect restrictions on the path name to the restricted access directory. This allows intruders to gain unauthorized access to protected information.

The vulnerability of Vivotek IP7137 micro-programmed software cameras is related to incorrect restrictions on the path name to the restricted access directory. Exploiting this vulnerability could allow a malicious actor, operating remotely, to gain unauthorized access to protected information...

6.8CVSS5.8AI score0.00808EPSS
SaveExploits0References2Affected Software1
RedhatCVE
RedhatCVE
•added 2026/01/13 10:52 p.m.•15 views

CVE-2025-66051

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

9.8CVSS6.8AI score0.00808EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2026/01/13 10:52 p.m.•12 views

CVE-2025-66049

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

8.7CVSS6.2AI score0.00416EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2026/01/13 10:52 p.m.•16 views

CVE-2025-66052

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

9.8CVSS7AI score0.01511EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2026/01/13 10:52 p.m.•14 views

CVE-2025-66050

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.8CVSS6.9AI score0.00383EPSS
SaveExploits0References1
OSV
OSV
•added 2026/01/09 12:15 p.m.•9 views

CVE-2025-66049

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

7.5CVSS5.8AI score0.00416EPSS
SaveExploits0References1
OSV
OSV
•added 2026/01/09 12:15 p.m.•14 views

CVE-2025-66052

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

7.2CVSS5.8AI score0.01511EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•25 views

CVE-2025-66049

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

8.7CVSS0.00416EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•16 views

CVE-2025-66051

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.9CVSS0.00808EPSS
SaveExploits0References1
OSV
OSV
•added 2026/01/09 12:15 p.m.•14 views

CVE-2025-66051

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.5CVSS5.7AI score0.00808EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•22 views

CVE-2025-66050

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.8CVSS0.00383EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•17 views

CVE-2025-66052

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS0.01511EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/01/09 11:54 a.m.•9 views

CVE-2025-66052 Command injection in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS6.6AI score0.01511EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:54 a.m.•48 views

CVE-2025-66052

The CVE-2025-66052 entry concerns the Vivotek IP7137 camera with firmware 0200a. The vulnerability is a command injection in /cgi-bin/admin/setparam.cgi via the non-sanitized system_ntpIt parameter, exploitable by a user with administrative privileges. The issue is compounded by CVE-2025-66050, w...

8.6CVSS7.1AI score0.01511EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2026/01/09 11:54 a.m.•49 views

CVE-2025-66052 Command injection in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS0.01511EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:54 a.m.•32 views

CVE-2025-66051

CVE-2025-66051 affects the Vivotek IP7137 camera running firmware 0200a. A path traversal flaw allows an authenticated attacker to access resources outside the webroot via a direct HTTP request. The issue is linked to end-of-life status of the product and there is no expected fix. The vulnerabili...

6.9CVSS6.4AI score0.00808EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2026/01/09 11:54 a.m.•43 views

CVE-2025-66051 Path traversal in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.9CVSS0.00808EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/09 11:53 a.m.•69 views

CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.3CVSS0.00383EPSS
SaveExploits0References1