Lucene search
K

7 matches found

NVD
NVD
added 2021/03/11 9:15 p.m.9 views

CVE-2021-22713

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...

7.8CVSS0.00367EPSS
Exploits0References1
OSV
OSV
added 2021/03/11 9:15 p.m.0 views

CVE-2021-22713

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...

7.5CVSS6AI score0.00367EPSS
Exploits0References1
CVE
CVE
added 2021/03/11 8:15 p.m.53 views

CVE-2021-22713

CVE-2021-22713 affects Schneider Electric PowerLogic meters: PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600. The root cause is a CWE-119 improper restriction of operations within the bounds of a memory buffer, which can cause the meter to reboot. The vulnerability ...

7.8CVSS7.5AI score0.00367EPSS
Exploits0References1Affected Software1
CNNVD
CNNVD
added 2021/03/11 12:0 a.m.2 views

Schneider Electric PowerLogic 缓冲区错误漏洞

Schneider Electric PowerLogic is an industrial control device from Schneider Electric, France. It provides increased power factor to improve power quality and troubleshoot power failures to protect networks, devices, and operators. A security vulnerability exists in PowerLogic, which stems from a...

7.8CVSS7.5AI score0.00367EPSS
Exploits0References2
NVD
NVD
added 2021/02/19 4:15 p.m.6 views

CVE-2021-22702

A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 see notification for affected versions, that could cause disclosure of user credentials when a malicious actor...

7.5CVSS0.00195EPSS
Exploits0References1
CVE
CVE
added 2021/02/19 3:13 p.m.43 views

CVE-2021-22702

CVE-2021-22702 affects Schneider Electric PowerLogic devices (ION7400/7650/7700-73xx/83xx-84xx-85xx/8600, ION8650, ION8800, ION9000 and PM800). Root cause: cleartext transmission of sensitive information via Telnet, exposing credentials if an attacker eavesdrops network traffic. Documented impact...

7.5CVSS7.2AI score0.00195EPSS
Exploits0References1Affected Software1
Positive Technologies
Positive Technologies
added 2021/02/09 12:0 a.m.3 views

PT-2021-3898

Name of the Vulnerable Software and Affected Versions PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 affected versions not specified Description A Cleartext transmission of sensitive information issue exists, which could cause disclosure of...

7.8CVSS7.1AI score0.00195EPSS
Exploits0References8