Lucene search
+L

14 matches found

KittySploit
KittySploit
•added 2026/08/02 8:51 p.m.•7 views

IEC 61850 MMS Client

Connects to an IEC 61850 MMS server ISO-on-TCP, completes COTP + Initiate, and creates an interactive MMS shell session. !/usr/bin/env python3 -- coding: utf-8 -- """IEC 61850 MMS bind listener — opens an MMS session for identify / directory.""" from kittysploit import from...

5.9AI score
SaveExploits0References1
KittySploit
KittySploit
•added 2026/07/10 11:31 a.m.•2 views

IEC 61850 MMS Identify

Probe TCP/102 for IEC 61850 MMS COTP + initiate and distinguish from Siemens S7comm on the same port. !/usr/bin/env python3 -- coding: utf-8 -- """Detect IEC 61850 MMS servers on ISO-on-TCP port 102.""" from future import annotations import json from kittysploit import from...

5.9AI score
SaveExploits0References1
CNNVD
CNNVD
•added 2025/02/13 12:00 a.m.•16 views

Schneider Electric Enerlin has a vulnerability in input validation.

The Schneider Electric Enerlin is a series of communication devices from Schneider Electric France. The Schneider Electric Enerlin suffers from an input validation error vulnerability that stems from the inclusion of an improper input validation vulnerability that could cause a denial of service ...

6.9CVSS5.8AI score0.00383EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•37 views

Hitachi Energy IEC 61850 MMS-Server Improper Resource Shutdown or Release (CVE-2022-3353)

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections...

7.5CVSS7.1AI score0.01105EPSS
SaveExploits0References12
NVD
NVD
•added 2023/02/21 2:15 p.m.•46 views

CVE-2022-3353

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...

7.5CVSS6.4AI score0.01105EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•43 views

Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...

5.9CVSS6.3AI score0.01155EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/21 12:00 a.m.•15 views

CVE-2018-16563: Undefined Security Weakness

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...

5.9CVSS5.6AI score0.01155EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2019/02/12 12:00 a.m.•12 views

PT-2019-1396

Name of the Vulnerable Software and Affected Versions Firmware variant IEC 61850 for EN100 Ethernet module versions prior to V4.35 Firmware variant MODBUS TCP for EN100 Ethernet module all versions Firmware variant DNP3 TCP for EN100 Ethernet module all versions Firmware variant IEC104 for EN100...

7.8CVSS0.01155EPSS
SaveExploits0References4
Prion
Prion
•added 2018/07/23 9:29 p.m.•31 views

Design/Logic Flaw

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3Affected Software3
NVD
NVD
•added 2018/07/23 9:29 p.m.•44 views

CVE-2018-11452

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2018/07/23 9:00 p.m.•45 views

CVE-2018-11451

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.3AI score0.02389EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/07/23 12:00 a.m.•8 views

CVE-2018-11451: Improper Input Validation

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS6.9AI score0.02389EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/07/23 12:00 a.m.•7 views

CVE-2018-11452: Improper Input Validation

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS6.9AI score0.02389EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2018/07/23 12:00 a.m.•6 views

PT-2018-2519

Name of the Vulnerable Software and Affected Versions Firmware variant IEC 61850 for EN100 Ethernet module versions prior to V4.33 Firmware variant PROFINET IO for EN100 Ethernet module all versions Firmware variant Modbus TCP for EN100 Ethernet module all versions Firmware variant DNP3 TCP for...

7.8CVSS0.02389EPSS
SaveExploits0References7
Rows per page
Query Builder