1687 matches found
Campaigns abusing corporate trusted infrastructure hunt for corporate credentials on ICS networks
Main facts Kaspersky ICS CERT has uncovered a number of spyware campaigns targeting industrial enterprises. Operators of these campaigns hunt for corporate credentials, aiming to commit financial fraud or to sell them to other malicious actors. Spearphishing emails with malicious attachments sent...
Mitsubishi Electric MELSEC-F Series
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC-F Series Vulnerability: Improper Initialization 2. RISK EVALUATION Successful exploitation of this vulnerability may cause a denial-of-service condition in the...
Mitsubishi Electric MELSEC-F Series
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC-F Series Vulnerability: Lack of Administrator Control Over Security 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a...
Fernhill SCADA
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Fernhill Software, Ltd. Equipment: Fernhill SCADA Server Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service...
Moxa MGate Protocol Gateways
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Moxa Equipment: MGate MB3180/MB3280/MB3480 Series Protocol Gateways Vulnerability: Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of this vulnerability could...
Johnson Controls exacq Enterprise Manager
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Exacq Technologies, a subsidiary of Johnson Controls, Inc. Equipment: exacq Enterprise Manager Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability...
WECON LeviStudioU
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: WECON Equipment: LeviStudioU Vulnerabilities: Stack-based Buffer Overflow, Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow remote code execution. 3. TECHNICAL...
New PseudoManuscrypt Malware Infected Over 35,000 Computers in 2021
Industrial and government organizations, including enterprises in the military-industrial complex and research laboratories, are the targets of a new malware botnet dubbed PseudoManyscrypt that has infected roughly 35,000 Windows computers this year alone. The name comes from its similarities to...
‘PseudoManuscrypt’ Mass Spyware Campaign Targets 35K Systems
Researchers have tracked new spyware – dubbed “PseudoManuscrypt” because it’s similar to “Manuscrypt” malware from the Lazarus advanced persistent threat APT group – that’s attempted to scribble itself across more than 35,000 targeted computers in 195 countries. Kaspersky researchers said in a...
PseudoManuscrypt: a mass-scale spyware attack campaign
In June 2021, Kaspersky ICS CERT experts identified malware whose loader has some similarities to the Manuscrypt malware, which is part of the Lazarus APT groups arsenal. In 2020, the group used Manuscrypt in attacks on defense enterprises in different countries. These attacks are described in th...
CISA Releases Security Advisory on WebHMI Vulnerabilities
CISA has released an Industrial Controls Systems ICS advisory detailing vulnerabilities in Distributed Data Systems WebHMI products. A remote attacker could exploit these vulnerabilities to take control of an affected system. CISA encourages users and administrators to review ICS advisory...
Hitachi Energy PCM600 Update Manager
1. EXECUTIVE SUMMARY CVSS v3 6.7 Vendor: Hitachi Energy Equipment: PCM600 Update Manager Vulnerability: Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to bypass the certificate validation and install an untrusted software...
icscoffee.com Cross Site Scripting vulnerability OBB-2288296
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
icslondon.com Cross Site Scripting vulnerability OBB-2283303
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
icslegal.com Cross Site Scripting vulnerability OBB-2283302
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
WECON PLC Editor
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: WECON Equipment: PLC Editor Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow arbitrary code execution. 3. TECHNICAL DETAILS 3.1...
14 security vulnerabilities reported in BusyBox Linux utility
By Deeba Ahmed For your information, BusyBox is generally used by embedded devices like IoT products or ICS industrial control systems. This is a post from HackRead.com Read the original post: 14 security vulnerabilities reported in BusyBox Linux utility...
CISA Releases Security Advisory on Siemens Nucleus Real-Time Operating Systems
CISA has released an Industrial Control Systems ICS advisory detailing multiple vulnerabilities found in Siemens Nucleus Real-Time Operating Systems RTOS and supporting libraries. A remote attacker could exploit some of these vulnerabilities to take control of an affected system. CISA encourages...
Siemens SIMATIC WinCC (Update E)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Ransomware Attacks against Water Treatment Plants
According to a report from CISA last week, there were three ransomware attacks against water treatment plants last year. WWS Sector cyber intrusions from 2019 to early 2021 include: In August 2021, malicious cyber actors used Ghost variant ransomware against a California-based WWS facility. The...