1930 matches found
Fuji Electric V-Server
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: V-Server Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being accessed; several heap-based buffer overflows...
Pwn2Own Expands Into Industrial Control Systems Hacking
Industrial control systems ICS used to manage critical infrastructure and manufacturing will be the main target in next year’s popular Pwn2Own’s annual hacking competition. Over the past few years, Pwn2Own – a hacking contest that draws in white-hat hackers looking for fame and fortune through...
Moxa EDR-810 - Command Injection Information Disclosure
Moxa EDR-810 - Command Injection Information Disclosure During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And th...
Moxa EDR-810 - Command Injection / Information Disclosure
During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And the other one is an improper access control found on the w...
Moxa EDR-810 - Command Injection / Information Disclosure Vulnerabilities
During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And the other one is an improper access control found on the w...
On-Board 'Mystery Boxes' Threaten Global Shipping Vessels
Commercial shipping environments are rife with vulnerabilities, according to researchers – up to and including unpatched “mystery boxes” that no one knows anything about. “In every single nautical pen test to date we have unearthed a system or device, that of the few crew that were aware, no one...
Operational Technology Networks or OT
Operational Technology Networks or OT Notes: It’s mixing up OT with maritime, so probably isn’t suitable as is. The first section is really good, very relevant. We can use all of that. Once we get in to NMEA data, then it goes off topic. I suggest: Network equipment such as the Scalance Then a...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery
Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...
SMA Solar Technology AG Sunny WebBox 1.6 Cross Site Request Forgery
Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Vulnerability
Exploit for hardware platform in category web applications Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware...
Siemens PROFINET Devices (Update K)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
GE Mark VIe Controller
1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: GE Equipment: Mark VIe Controller Vulnerabilities: Improper Authorization, Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create...
EulerOS 2.0 SP5 : libical (EulerOS-SA-2019-1915)
According to the version of the libical packages installed, the EulerOS installation on the remote host is affected by the following vulnerability : - libical allows remote attackers to cause a denial of service use-after-free and possibly read heap memory via a crafted ics file.CVE-2016-9584 Not...
Pwning a Siemens Scalance ICS switch through ARM reversing
We’ve been working in industrial control systems security for a long time. Several of the team here used to work in OT control rooms or support SCADA environments. Whilst pen testing a ship control system, we noticed a heavy reliance on Siemens Scalance industrial ethernet switches, so bought a...
EZAutomation EZ PLC Editor
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: EZAutomation Equipment: EZ PLC Editor Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to...
Fuji Electric Alpha5 Smart Loader
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: Alpha5 Smart Loader Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code under the privileges of...
DEF CON 2019: Delta ICS Flaw Allows Total Industrial Takeover
A serious vulnerability in a commonly used Delta industrial control system has been found that could allow malicious actors on the same network complete control of the operating system. The Delta enteliBUS Manager centralizes control for various pieces of hardware often found in corporate or...
Sea Turtle keeps on swimming, finds new victims, DNS hijacking techniques
By Danny Adamitis with contributions from Paul Rascagneres. Executive summary After several months of activity, the actors behind the "Sea Turtle" DNS hijacking campaign are not slowing down. Cisco Talos recently discovered new details that suggest they regrouped after we published our initial...
Rockwell Automation PanelView 5510
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: PanelView 5510 Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote unauthenticated user to gain root privileges on the...