Siemens RUGGEDCOM ROS (Update A)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens PROFINET Devices (Update K)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Johnson Controls exacqVision Enterprise System Manager
1. EXECUTIVE SUMMARY CVSS v3 6.7 Vendor: Johnson Controls Equipment: exacqVision Enterprise System Manager ESM Vulnerability: Improper Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow malicious code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS...
Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM (Update I)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Horner Automation Cscape
1. EXECUTIVE SUMMARY CVSS v3 6.6 ATTENTION: Low skill level to exploit Vendor: Horner Automation Equipment: Cscape Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being accessed, allow the attacker to read...
Threat predictions for industrial security in 2019
Kaspersky Security Bulletin: Threat Predictions for 2019 Cryptocurrency threat predictions for 2019 Cyberthreats to financial institutions 2019: overview and predictions The past few years have been very intense and eventful when it comes to incidents affecting the information security of...
ICS Security Plagued with Basic, Avoidable Mistakes
At least 33 percent of the security issues found in industrial control systems ICS are rated as being of high or critical risk. FireEye iSIGHT Intelligence compiled data from dozens of ICS security health assessment engagements performed by its Mandiant division, and found that these issues inclu...
ICS Tactical Security Trends: Analysis of the Most Frequent Security Risks Observed in the Field
Introduction FireEye iSIGHT Intelligence compiled extensive data from dozens of ICS security health assessment engagements ICS Healthcheck performed by Mandiant, FireEye's consulting team, to identify the most pervasive and highest priority security risks in industrial facilities. The information...
icsd.ill.fr Open Redirect vulnerability
Vulnerable URL: http://icsd.ill.fr/icsd/geturl.php?url=data%3Atext%2Fhtml%3Bbase64%2CPHNjcmlwdD5hbGVydCgvT1BFTkJVR0JPVU5UWS8pPC9zY3JpcHQ%2B Details: Description| Value ---|--- Patched:| Verification in progress Latest check for patch:| 03.01.2018 Vulnerability type:| Open Redirect Vulnerability...
June 27, 2017 – Morning Cyber Coffee Headlines – “Helen Keller” Edition
Good morning! Sit with Carbon Black this morning over a cup of coffee or tea and browse a few industry headlines to get the day started. We’ve got just enough information below to get you through that first cup…enjoy! June 27, 2017 - Headlines 'Petya' ransomware attack strikes companies across...
IRONGATE ICS Malware: Nothing to See Here...Masking Malicious Activity on SCADA Systems
In the latter half of 2015, the FireEye Labs Advanced Reverse Engineering FLARE team identified several versions of an ICS-focused malware crafted to manipulate a specific industrial process running within a simulated Siemens control system environment. We named this family of malware IRONGATE...
Researcher Releases Database of Known-Good ICS and SCADA Files
A prominent security researcher has put together a new database of hundreds of thousands of known-good files from ICS and SCADA software vendors in an effort to help users and other researchers identify legitimate files and home in on potentially malicious ones. The database, known as WhiteScope,...
Is It Time for Certified ICS Security Specialists?
The information security field is full of certifications – CompTIA, GIAC, CHE, ISC2 CISSP, CISM, with a vast number of areas and directions within these families. In the industrial space, the most “unsecured” enterprise sector compared to well-established information security practice in most...
Attacking ICS Systems 'Like Hacking in the 1980s'
PUNTA CANA–Here’s how nuts the world of ICS security is: Jonathan Pollet, a security consultant who specializes in ICS systems, was at a Texas amusement park recently and the ride he was waiting for was malfunctioning. The operator told him the ride used a Siemens PLC as part of the control syste...
Electric Cybersecurity Regulations Have Serial Problem
A class of SCADA vulnerabilities discussed at a recent conference is getting attention not only for the risks they pose to master control systems at electric utilities, but also for illuminating a dangerous gap in important critical infrastructure regulations. Researchers Adam Crain and Chris...
WellinTech KingSCADA Stack-Based Buffer Overflow
OVERVIEW An anonymous researcher working with HP’s Zero Day Initiative has identified a stack-based buffer overflow in the WellinTech KingSCADA Stack. WellinTech has produced a patch that mitigates this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following...
Cleartext Credential Found in ICS Device Firmware
Industrial control systems are rife with security issues, not the least of which is the use of hard-coded credentials. In order to minimize downtime, developers and administrators build in passwords to expedite remote troubleshooting in the event of a system crash or failure. Problems arise when ...
Malware Infects Two Power Plants Lacking Basic Security Controls
During the past three months, unnamed malware infected two power plants’ control systems using unprotected USB drives as an attack vector. At both companies, a lack of basic security controls made it much easier for the malicious code to reach critical networks. In one instance, according to a...
DHS Warns ICS, SCADA Owners About Increase in Malicious Activity
An alert from the Department of Homeland Security late last week urges private- and public-sector industrial control system ICS owners to be proactive in auditing the security, particularly, authentication controls of their systems. The alert is in response to a growing concern over the number of...
Researchers Warn of Prison Hacks, Opening Cell Doors
In news that seems like it could be lifted from an old 24 or Prison Break plotline, authorities are concerned by new research that claims hackers could remotely open the cell doors of federal prisons. In addition to staging a jailbreak, hackers could sabotage a prison’s intercom system and...