Lucene search
+L

613 matches found

Saint
Saint
added 2013/02/11 12:00 a.m.58 views

Schneider Electric Interactive Graphical SCADA System Data Collector Overflow

Added: 02/11/2013 CVE: CVE-2013-0657 BID: 57449 OSVDB: 89324 Background Schneider Electric Interactive Graphical SCADA System IGSS is a supervisory control and data acquisition SCADA system designed to monitor and control industrial processes. The Data Collector DC.exe component listens on port...

10CVSS7.6AI score0.21262EPSS
SaveExploits9
Exploit DB
Exploit DB
added 2013/02/02 12:00 a.m.53 views

CADA 3S CoDeSys Gateway Server - Directory Traversal (Metasploit)

This module requires Metasploit: http://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework http://metasploit.com require 'msf/core' class MetasploitModule 'SCADA 3S CoDeSys Gateway Server Directory Traversal', 'Description' = %q This module exploits a directory...

10CVSS5.2AI score0.6487EPSS
SaveExploits9
ICS
ICS
added 2013/01/28 7:00 a.m.42 views

Galil RIO-47100 Improper Input Validation

Overview This advisory provides mitigation details for a vulnerability affecting the Galil RIO-47100 “Pocket PLC.” Researcher Jon Christmas of Solera Networks has identified an improper validation vulnerability in the Galil RIO-47100 PLC, which can result in a loss of availability. Galil has...

7.1CVSS6.3AI score0.02793EPSS
SaveExploits6References10
ThreatPost
ThreatPost
added 2013/01/23 4:25 p.m.45 views

Password Cracker Targets Siemens S7 PLCs

Siemens S7 programmable logic controllers, the same PLC family exploited by the Stuxnet malware, are in the crosshairs of a password-cracking tool that is capable of stealing credentials from industrial control systems. PLCs are microprocessors that automate mechanical processes inside factories,...

0.3AI score
SaveExploits0References7
ThreatPost
ThreatPost
added 2013/01/17 7:56 p.m.15 views

Researchers Highlight Medical Device Security at Annual ICS Conference

Two popular industrial control system ICS researchers this week demonstrated how easily medical devices, including a Philips-branded machine that regularly interacts with x-ray machines and other hospital equipment, can be hacked. At Digital Bond’s annual SCADA Security Scientific Symposium S4...

0.4AI score
SaveExploits0References9
The Hacker News
The Hacker News
added 2013/01/16 6:00 p.m.10 views

Malware Infects US Power Plants through USB Drives

The US Department of Homeland Security's Cyber Emergency Response Team has released a report, which stated that two American electrical power plants were compromised late last year and has identified a number of glaring electronic vulnerabilities. Some unknown malware infected two power plants...

6.9AI score
SaveExploits0
The Hacker News
The Hacker News
added 2013/01/16 7:00 a.m.20 views

Malware Infects US Power Plants through USB Drives

The US Department of Homeland Security’s Cyber Emergency Response Team has released a report, which stated that two American electrical power plants were compromised late last year and has identified a number of glaring electronic vulnerabilities. Some unknown malware infected two power plants...

6.9AI score
SaveExploits0
ThreatPost
ThreatPost
added 2013/01/15 2:22 a.m.13 views

Malware Infects Two Power Plants Lacking Basic Security Controls

During the past three months, unnamed malware infected two power plants’ control systems using unprotected USB drives as an attack vector. At both companies, a lack of basic security controls made it much easier for the malicious code to reach critical networks. In one instance, according to a...

1.2AI score
SaveExploits0References1
ICS
ICS
added 2013/01/10 7:00 a.m.41 views

Canary Labs Inc Trend Link Insecure ActiveX Control Method

Overview This advisory provides mitigation details for a vulnerability in the Canary Labs, Inc. Trend Link software. Researcher Kuang-Chun Hung of Security Research and Service Institute−Information and Communication Security Technology Center ICST has identified an insecure ActiveX control metho...

8.5CVSS7.3AI score0.0129EPSS
SaveExploits0References10
ICS
ICS
added 2012/12/30 7:00 a.m.63 views

Rockwell Automation FactoryTalk RNADiagReceiver

Overview This Updated Advisory is a follow-up to the original Advisory titled “ICSA-12-088-01 – Rockwell Automation FactoryTalk RNADiagReceiver DOS Vulnerabilities” that was published March 28, 2012 on the ICS-CERT web page. This advisory is a follow-up to ICS-CERT Alert...

5CVSS6.5AI score0.1021EPSS
SaveExploits1References10
ICS
ICS
added 2012/12/25 7:00 a.m.50 views

Ecava IntegraXor ActiveX Directory Traversal

Overview Independent researchers Billy Rios and Terry McCorkle have identified a Path Traversal vulnerability in the Ecava IntegraXor application. Ecava has produced an update that mitigates this vulnerability. The researchers have validated that the patch fixes this vulnerability. Affected...

9.3CVSS7AI score0.05948EPSS
SaveExploits0References10
ICS
ICS
added 2012/12/12 12:00 a.m.40 views

Siemens Automation License Manager Uncontrolled Resource Consumption

Overview This advisory provides mitigation details for a vulnerability that impacts the Siemens Automation License Manager ALM. Siemens ProductCERT has identified an uncontrolled resource consumption vulnerabilitySSA-783261, https://cert-portal.siemens.com/productcert/pdf/ssa-783261.pdf, Web site...

3.3CVSS6.6AI score0.00892EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2012/12/10 6:01 p.m.12 views

Team Ghostshell Allegedly Dumps 1.6 M Aerospace, Nanotechnology Records

Hacktivist collective Team Ghostshell is claiming this morning to have spilled 1.6 million accounts from a handful of companies in the aerospace, nanotechnology, banking, law, education and government realm, a hack the group deems Project White Fox. The group claims White Fox is its “final stand”...

0.4AI score
SaveExploits0References4
ICS
ICS
added 2012/11/04 6:00 a.m.58 views

GE Intelligent Platforms Proficy Plant Applications Memory Corruption Vulnerabilities

Overview ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI concerning multiple memory corruption vulnerabilities in the GE Intelligent Platforms Proficy Plant Applications. These vulnerabilities were reported to ZDI by independent security researcher Luigi...

10CVSS7.7AI score0.09164EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/28 6:00 a.m.41 views

7-Technologies Termis DLL Hijacking

Overview ICS-CERT originally released Advisory ICSA-12-025-02P on the US-CERT secure portal on January 25, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute−Information and...

9.3CVSS6.7AI score0.01787EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/27 6:00 a.m.46 views

Ocean Data Systems Dream Reports XSS and Write Access Violation Vulnerabilities

Overview Independent researchers Billy Rios and Terry McCorkle identified cross-site scripting XSS and write access violation vulnerabilities in Ocean Data Systems Dream Report application. ICS-CERT has coordinated these vulnerabilities with Ocean Data Systems, which has produced a new version th...

9.3CVSS6.9AI score0.04282EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/21 6:00 a.m.77 views

Schneider Electric Quantum Ethernet Module Hard-Coded Credentials

OVERVIEW --------- Begin Update B Part 1 of 3 -------- This updated advisory is a follow-up to the updated advisory titled ICSA-12-018-01A Schneider Electric Quantum Ethernet Module Hard-Coded Credentials that was published on June 04, 2013, on the ICS-CERT Web site. It is also a follow-up to the...

10CVSS7.8AI score0.03894EPSS
SaveExploits1References10
ICS
ICS
added 2012/10/16 6:00 a.m.69 views

ING. Punzenberger COPA-DATA GMBH DoS Vulnerabilities

Overview ICS-CERT originally released Advisory ICSA-12-013-01P on the US-CERT secure portal on January 13, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute--Information and...

7.5CVSS7.8AI score0.03044EPSS
SaveExploits0References10
The Hacker News
The Hacker News
added 2012/10/12 6:04 p.m.11 views

SCADA Hacking : Exploit released to Hack Solar Energy Plants

ICS-CERT - Industrial Control Systems Cyber Emergency Response Team has released the Advisory titled ICS-ALERT-12-284-01 - Sinapsi eSolar Light Multiple Vulnerabilities. They Report about report multiple vulnerabilities with proof-of-concept PoC exploit code that affecting the Sinapsi eSolar Ligh...

9.2AI score
SaveExploits0
ICS
ICS
added 2012/10/09 6:00 a.m.66 views

3S CoDeSys Vulnerabilities

Overview This advisory is a follow-up to the alert update, ICS-ALERT-11-336-01A 3S CoDeSys Vulnerabilities, which was released on the ICS-CERT Web page on December 02, 2011. Security researcher Celil Unuver SignalSec LLC and independent researcher Luigi Auriemma have identified vulnerabilities in...

10CVSS7.6AI score0.72714EPSS
SaveExploits12References10
Rows per page
Query Builder