Lucene search
+L

211 matches found

CNNVD
CNNVD
•added 2023/11/14 12:00 a.m.•23 views

Siemens SCALANCE 资源管理错误漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

6.5CVSS6.7AI score0.01001EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2023/11/14 12:00 a.m.•34 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

6.9CVSS6.5AI score0.00688EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2023/10/25 12:00 a.m.•19 views

Bosch ctrlX HMI Web Panel WR21 Security Vulnerability

Bosch ctrlX HMI Web Panel WR21 is an HMI panel from Bosch Germany. A security vulnerability exists in the Bosch ctrlX HMI Web Panel WR21 version, which originated from a vulnerability that allows an attacker to install an arbitrary Android application while locked in Kiosk mode and use it to acce...

7.3CVSS6.9AI score0.00335EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2023/10/21 12:00 a.m.•33 views

Weintek cMT3000 HMI Web CGI Panel Buffer Overflow

The vulnerability of Weintek’s cMT3000 HMI Web CGI panel software lies in buffer overflow attacks within the stack. Exploiting this vulnerability could allow an attacker to bypass the authentication process...

10CVSS8.1AI score0.01107EPSS
SaveExploits1References6Affected Software7
BDU FSTEC
BDU FSTEC
•added 2023/08/09 12:00 a.m.•16 views

HCI Interface DoS

The vulnerability of the HCI interface, which operates according to the IEC 60870-5-104 standard, in the Hitachi Energy RTU500 programmable logic controllers is related to buffer overflow in the stack. Exploiting this vulnerability could allow a remote attacker to cause a service failure...

7.8CVSS7.6AI score0.00645EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2023/08/09 12:00 a.m.•22 views

HCI Interface DoS

The vulnerability of the HCI interface, which operates according to the IEC 60870-5-104 standard, in the Hitachi Energy RTU500 programmable logic controllers is related to buffer overflow in the stack. Exploiting this vulnerability could allow a remote attacker to cause a service failure...

7.8CVSS7.6AI score0.00712EPSS
SaveExploits0References2Affected Software1
osv_cve
osv_cve
•added 2023/06/14 8:15 a.m.•23 views

CVE-2023-1049

A CWE-94: Improper Control of Generation of Code 'Code Injection' vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI...

7.8CVSS5.9AI score0.00597EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2023/06/07 12:00 a.m.•21 views

Delta Electronics DOPSoft 安全漏洞

Delta Electronics DOPSoft is a set of human machine interface HMI software from Delta Electronics Taiwan, China. A security vulnerability exists in Delta Electronics DOPSoft version 1.0.0.4 and prior versions, which stems from susceptibility to a stack-based buffer overflow. An attacker can explo...

7.8CVSS8.2AI score0.00347EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2023/06/01 2:15 a.m.•16 views

CVE-2023-29154

SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...

7.2CVSS6AI score0.41443EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2023/06/01 2:15 a.m.•20 views

CVE-2023-28657

Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...

8.8CVSS7.3AI score0.00708EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2023/06/01 2:15 a.m.•8 views

CVE-2023-29154

SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...

7.2CVSS6.1AI score0.41443EPSS
SaveExploits0References4Affected Software1
CNNVD
CNNVD
•added 2023/05/31 12:00 a.m.•21 views

Contec CONPROSYS HMI System 安全漏洞

Contec CONPROSYS HMI System is an HTML5 technology-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which stems from an incorrect assignment ...

7.8CVSS7.7AI score0.00182EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2023/05/31 12:00 a.m.•20 views

Contec CONPROSYS HMI System SQL注入漏洞

Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which originates from the presence of SQL injection...

7.2CVSS7.7AI score0.41443EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2023/05/31 12:00 a.m.•25 views

Contec CONPROSYS HMI System 代码问题漏洞

Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3 that stems from a server-side request forgery...

4.9CVSS6.5AI score0.00641EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2023/05/31 12:00 a.m.•23 views

Contec CONPROSYS HMI System 安全漏洞

Contec CONPROSYS HMI System is an HTML5 technology-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which stems from database account details...

8.1CVSS7.7AI score0.00431EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
•added 2023/05/31 12:00 a.m.•24 views

Horner Automation Cscape EnvisionRV Buffer Overflow RCE

The vulnerability of the Horner Automation Cscape EnvisionRV remote control access software and the Cscape software lies in the execution of operations outside the buffer in memory. Exploiting this vulnerability allows an attacker to execute arbitrary code by causing the user to open a specially...

7.8CVSS8.1AI score0.00227EPSS
SaveExploits0References5Affected Software1
Positive Technologies
Positive Technologies
•added 2023/05/23 12:00 a.m.•21 views

PT-2023-2953 · Horner Automation · Cscape

Name of the Vulnerable Software and Affected Versions: Horner Automation Cscape affected versions not specified Description: The issue is related to a lack of proper validation of user-supplied data when parsing project files, such as HMI files. This could lead to an out-of-bounds read, potential...

7.8CVSS7.7AI score0.00227EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2023/05/23 12:00 a.m.•18 views

PT-2023-2870 · Horner Automation · Horner Automation Cscape

Name of the Vulnerable Software and Affected Versions: Horner Automation Cscape affected versions not specified Description: The issue is related to a buffer overflow when parsing project files, such as HMI files. This could lead to an out-of-bounds write, allowing an attacker to execute arbitrar...

7.8CVSS7.8AI score0.00227EPSS
SaveExploits0References7
CNNVD
CNNVD
•added 2023/03/31 12:00 a.m.•15 views

Contec CONPROSYS HMI System 安全漏洞

Contec CONPROSYS HMI System is an HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product based on HTML5 technology from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System. An attacker could exploit the vulnerability to perform a SQL...

7.7AI score
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2023/01/20 12:00 a.m.•21 views

PT-2023-18441 · Unknown · Conprosys Hmi System

Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions 3.4.5 and earlier Description: The issue allows a remote unauthenticated attacker to bypass access restrictions and obtain the server certificate, including the private key of the product, due to an improper...

7.5CVSS7.6AI score0.01137EPSS
SaveExploits0References7
Rows per page
Query Builder