Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

5CVSS6.8AI score0.00771EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/03/25 6:20 p.m.21 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5AI score0.00771EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2016/01/22 11:59 a.m.2 views

CVE-2015-7909

Stack-based buffer overflow in Hospira Communication Engine CE before 1.2 in LifeCare PCA Infusion System 5.07, Plum A+ Infusion System 13.40, and Plum A+3 Infusion System 13.40 allows remote attackers to cause a denial of service or possibly have unspecified other impact via traffic on TCP port...

7.5CVSS6.2AI score0.01112EPSS
SaveExploits0References2
NVD
NVD
added 2015/07/06 7:59 p.m.17 views

CVE-2015-3958

Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service forced manual reboot via a flood of TCP packets...

7.8CVSS7.8AI score0.02612EPSS
SaveExploits0References3
NVD
NVD
added 2015/07/06 7:59 p.m.19 views

CVE-2015-3957

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors...

4.6CVSS8.1AI score0.00544EPSS
SaveExploits0References3
NVD
NVD
added 2015/07/06 7:59 p.m.20 views

CVE-2015-3955

Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors...

10CVSS8.6AI score0.0675EPSS
SaveExploits0References3
NVD
NVD
added 2015/07/06 7:59 p.m.17 views

CVE-2015-1011

Hospira LifeCare PCA Infusion System before 7.0 has hardcoded credentials, which makes it easier for remote attackers to obtain access via unspecified vectors...

5CVSS7.4AI score0.02228EPSS
SaveExploits0References2
Prion
Prion
added 2015/07/06 7:59 p.m.15 views

Hardcoded credentials

Hospira LifeCare PCA Infusion System before 7.0 has hardcoded credentials, which makes it easier for remote attackers to obtain access via unspecified vectors...

5CVSS7.1AI score0.02228EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2015/07/06 7:59 p.m.13 views

Stack overflow

Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors...

10CVSS8.8AI score0.0675EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2015/07/06 7:59 p.m.22 views

CVE-2014-5406

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

9.3CVSS7.4AI score0.01242EPSS
SaveExploits0References5
Prion
Prion
added 2015/07/06 7:59 p.m.18 views

Design/Logic Flaw

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

9.3CVSS7AI score0.05162EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.21 views

CVE-2014-5406 Hospira LifeCare PCA Infusion System

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

7.6CVSS7.4AI score0.01242EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.21 views

CVE-2015-3958

Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service forced manual reboot via a flood of TCP packets...

6.7AI score0.02612EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.23 views

CVE-2015-1011

Hospira LifeCare PCA Infusion System before 7.0 has hardcoded credentials, which makes it easier for remote attackers to obtain access via unspecified vectors...

6.6AI score0.02228EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.19 views

CVE-2015-3957

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors...

6.6AI score0.00544EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.22 views

CVE-2015-3955

Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors...

8.2AI score0.0675EPSS
SaveExploits0References3
CVE
CVE
added 2015/07/06 7:10 p.m.53 views

CVE-2015-3958

CVE-2015-3958 affects Hospira LifeCare PCA Infusion System (Version 5.0 and earlier). The issue enables remote denial-of-service via a flood of TCP packets, forcing manual reboot. Impact is tied to vulnerable AppWeb/network services; exploitation details are discussed in ICS-CERT/NVD entries. Mit...

7.8CVSS6.9AI score0.02612EPSS
SaveExploits0References3Affected Software1
CNVD
CNVD
added 2015/06/26 12:0 a.m.5 views

Hospira Lifecare PCA Infusion Pump Information Disclosure Vulnerability

Hospira Lifecare PCA infusion Pump is a suite of smart infusion pump software from Hospira, USA. An information disclosure vulnerability exists in Hospira Lifecare PCA Infusion Pump. An attacker could exploit this vulnerability to gain access to sensitive information...

7.5CVSS6.4AI score0.00771EPSS
SaveExploits0References1