Lucene search
K

10 matches found

CISA
CISA
added 2023/06/01 12:0 p.m.4 views

CISA Releases Five Industrial Control Systems Advisories

CISA released five Industrial Control Systems ICS advisories on June 1, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-152-01 Advantech WebAccess-SCADA ICSA-23-152-02 HID Global SAFE ICSA-22-256-03 Delta...

7AI score
Exploits0References5
CNNVD
CNNVD
added 2021/11/26 12:0 a.m.4 views

Hitachi Energy Relion 输入验证错误漏洞

Hitachi Energy Relion is a power system for protection, control, measurement and monitoring from Hitachi Energy, Switzerland. A security vulnerability exists in the Hitachi Energy RTU500 series that stems from incorrect input validation in the APDU parser in the IEC 60870-5-104 function...

7.5CVSS7.3AI score0.0092EPSS
Exploits0References5
Cvelist
Cvelist
added 2021/11/18 4:35 p.m.57 views

CVE-2021-35534 Insufficient Security Control Vulnerability

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal databas...

7.2CVSS7.1AI score0.01666EPSS
Exploits0References3
OSV
OSV
added 2021/11/18 4:15 p.m.3 views

CVE-2021-35535

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process...

8.1CVSS7.3AI score0.00567EPSS
Exploits0References1
Prion
Prion
added 2021/11/18 4:15 p.m.20 views

Design/Logic Flaw

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process...

6.8CVSS7.8AI score0.00567EPSS
Exploits0References1Affected Software3
Cvelist
Cvelist
added 2021/11/18 3:53 p.m.30 views

CVE-2021-35535 Insufficient Security Control Vulnerability

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process...

8.1CVSS8.1AI score0.00567EPSS
Exploits0References1
CVE
CVE
added 2021/11/18 3:53 p.m.65 views

CVE-2021-35535

Hitachi Energy Relion 670/650/SAM600-IO series are affected by CVE-2021-35535, caused by an insecure default initialization during the boot process where a previous VxWorks image may be loaded in a tiny boot-time window, potentially allowing an attacker with front-network-port access to cause a r...

8.1CVSS7.9AI score0.00567EPSS
Exploits0References1Affected Software1
CNNVD
CNNVD
added 2021/11/18 12:0 a.m.5 views

Hitachi Energy Relion 系列安全漏洞

Hitachi Energy Relion is a Swiss Hitachi Energy company used to protect, control, measure and monitor for power systems. A security vulnerability exists in the Hitachi Energy Relion Relion 670/650/SAM600-IO Series that allows an attacker to gain access to the front-end network port and cause a...

8.1CVSS7.8AI score0.00567EPSS
Exploits0References5
CNNVD
CNNVD
added 2021/11/18 12:0 a.m.20 views

Hitachi Energy Relion 访问控制错误漏洞

Hitachi Energy Relion is used by Hitachi Energy Switzerland to protect, control, measure, and monitor power systems. A security vulnerability exists in the internal database access mechanism of the Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600, which arises from the product'...

9CVSS7AI score0.01666EPSS
Exploits0References7
Positive Technologies
Positive Technologies
added 2021/11/18 12:0 a.m.10 views

PT-2021-20957 · Hitachi Energy · Pwc600 +5

Name of the Vulnerable Software and Affected Versions: Hitachi Energy Relion 670 Series versions 2.0 through 2.2.3.4 Hitachi Energy Relion 670 Series version 2.2.4 Hitachi Energy Relion 670/650 Series versions 2.1 through 2.2.0 Hitachi Energy Relion 670/650 Series version 2.2.4 Hitachi Energy...

9CVSS6.9AI score0.01666EPSS
Exploits0References6
Rows per page
Query Builder