Lucene search
K

26 matches found

RedhatCVE
RedhatCVE
added 2025/05/23 7:30 a.m.3 views

CVE-2024-48121

The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...

6.5CVSS6.9AI score0.00214EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 7:5 a.m.5 views

CVE-2024-48126

HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...

9.8CVSS7.5AI score0.00394EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 7:5 a.m.2 views

CVE-2024-48123

An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...

8.4CVSS7.7AI score0.00177EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 7:5 a.m.4 views

CVE-2024-48125

An issue in the AsDB service of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to enumerate user credentials via crafted GIOP protocol requests...

7.5CVSS6.9AI score0.0036EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 7:5 a.m.3 views

CVE-2024-48122

Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...

6.7CVSS7AI score0.00163EPSS
Exploits0References1
NVD
NVD
added 2025/01/15 9:15 p.m.4 views

CVE-2024-48123

An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...

8.4CVSS0.00177EPSS
Exploits0References1
NVD
NVD
added 2025/01/15 9:15 p.m.6 views

CVE-2024-48121

The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...

6.5CVSS0.00214EPSS
Exploits0References1
NVD
NVD
added 2025/01/15 9:15 p.m.4 views

CVE-2024-48122

Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...

6.7CVSS0.00163EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/01/15 12:0 a.m.5 views

CVE-2024-48125

An issue in the AsDB service of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to enumerate user credentials via crafted GIOP protocol requests...

7.5AI score0.0036EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/01/15 12:0 a.m.3 views

CVE-2024-48126

HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...

9.6AI score0.00394EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/01/15 12:0 a.m.3 views

CVE-2024-48122

Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...

6.7AI score0.00163EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/01/15 12:0 a.m.3 views

CVE-2024-48121

The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...

6.5AI score0.00214EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/01/15 12:0 a.m.3 views

Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞

The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I, which stems from an issue in the AsDB service that allows an attacker to...

7.5CVSS6.8AI score0.0036EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/01/15 12:0 a.m.3 views

Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞

The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from an insecure default configuration that allows an...

6.7CVSS6.9AI score0.00163EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/01/15 12:0 a.m.10 views

CVE-2024-48121

The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...

0.00214EPSS
Exploits0References1
CVE
CVE
added 2025/01/15 12:0 a.m.64 views

CVE-2024-48125

CVE-2024-48125 affects the HI-SCAN 6040i Hitrax HX-03-19-I system via the AsDB service. The issue allows an attacker to enumerate user credentials by sending crafted GIOP protocol requests. Documented impact is credential enumeration with a base CVSS v3.1 score of 7.5 (High) and network access wi...

7.5CVSS6.9AI score0.0036EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2025/01/15 12:0 a.m.4 views

PT-2025-2792 · Unknown · Hi-Scan 6040I

Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I Description: The issue concerns hardcoded credentials in the system, which could allow unauthorized access to vendor support and service access. Recommendations: For HI-SCAN 6040i Hitrax HX-03-19-I, consider...

9.8CVSS7.2AI score0.00394EPSS
Exploits0References5
Cvelist
Cvelist
added 2025/01/15 12:0 a.m.8 views

CVE-2024-48126

HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...

0.00394EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/01/15 12:0 a.m.11 views

CVE-2024-48123

An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...

0.00177EPSS
Exploits0References1
CVE
CVE
added 2025/01/15 12:0 a.m.40 views

CVE-2024-48122

CVE-2024-48122 concerns the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I, where insecure default configurations enable an authenticated attacker with low privileges to escalate to root. The connected sources consistently describe the issue as an insecure default setup that permits local privi...

6.7CVSS7AI score0.00163EPSS
Exploits0References1
Rows per page