Lucene search
+L

1375 matches found

CVE
CVE
added 2021/08/02 12:45 p.m.110 views

CVE-2021-37167

CVE-2021-37167 affects the HMI3 Control Panel in Swisslog Healthcare Nexus Panel, specifically released builds prior to Nexus Software 7.2.5.7. An insecure permissions issue allows a user who logs in with default credentials to gain root access to the device, granting full control over device fun...

10CVSS9.5AI score0.01737EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2021/08/02 12:45 p.m.42 views

CVE-2021-37167

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

9.7AI score0.01737EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 12:44 p.m.109 views

CVE-2021-37166

CVE-2021-37166 affects Swisslog Healthcare Nexus Panel (HMI3 Control Panel). The issue is a buffer/connection handling vulnerability that occurs during startup when the HMI3 binds a local service to a TCP port on all interfaces and waits a long time for the GUI to connect, enabling an external at...

7.8CVSS7.6AI score0.02062EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2021/08/02 12:44 p.m.39 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8AI score0.02062EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2021/08/02 12:43 p.m.49 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.6AI score0.08227EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 12:43 p.m.119 views

CVE-2021-37160

CVE-2021-37160 impacts Swisslog Healthcare Nexus Panel firmware updates prior to Nexus Software 7.2.5.7, where there is no firmware validation (eg, cryptographic signature) during a firmware file upload. The vulnerability stems from missing validation during firmware update uploads, enabling pote...

9.8CVSS9.4AI score0.08227EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2021/08/02 12:42 p.m.38 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

10AI score0.03264EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 12:42 p.m.121 views

CVE-2021-37161

CVE-2021-37161 describes a buffer overflow in the Swisslog Healthcare Nexus Panel’s HMI3 Control Panel (pre Nexus Software 7.2.5.7) that can overwrite an internal queue data structure and lead to remote code execution. The impact is high (network, no auth, no user interaction). Remediation: upgra...

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
The Hacker News
The Hacker News
added 2021/08/02 12:03 p.m.172 views

PwnedPiper PTS Security Flaws Threaten 80% of Hospitals in the U.S.

Cybersecurity researchers on Monday disclosed a set of nine vulnerabilities known as "PwnedPiper" that left a widely-used pneumatic tube system PTS vulnerable to critical attacks, including a possibility of complete takeover. The security weaknesses, disclosed by American cybersecurity firm Armis...

10CVSS0.08227EPSS
SaveExploits0
NVD
NVD
added 2021/08/02 11:15 a.m.40 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS0.03264EPSS
SaveExploits0References4
Prion
Prion
added 2021/08/02 11:15 a.m.28 views

Buffer overflow

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

7.5CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2021/08/02 10:48 a.m.47 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

10AI score0.03264EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 10:48 a.m.102 views

CVE-2021-37165

Technical details about CVE-2021-37165 are not publicly available in the provided Connected documents. The initial description notes a buffer overflow enabling remote code execution in Nexus Panel software prior to 7.2.5.7, but no confirmed exploit or remediation is documented here.

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
The Hacker News
The Hacker News
added 2021/08/02 10:07 a.m.44 views

Solarmarker InfoStealer Malware Once Again Making its Way Into the Wild

Healthcare and education sectors are the frequent targets of a new surge in credential harvesting activity from what's a "highly modular" .NET-based information stealer and keylogger, charting the course for the threat actor's continued evolution while simultaneously remaining under the radar...

6.8AI score
SaveExploits0
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.12 views

Swisslog Healthcare Nexus Panel 数字错误漏洞

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability can be exploited to override the internal queue data structure, allowing for remote code execution...

9.8CVSS6.1AI score0.03264EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.19 views

Swisslog Healthcare Nexus Panel 数据伪造问题漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A code download without integrity check vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. The vulnerability stems from no file validation during the upload of an update. No details of the...

9.8CVSS5.7AI score0.08227EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.10 views

HMI3 Control Panel 信任管理问题漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...

9.8CVSS5.5AI score0.01439EPSS
SaveExploits0References7
CNVD
CNVD
added 2021/07/16 12:00 a.m.85 views

Ypsomed mylife App has an unspecified vulnerability

Ypsomed mylife App is an application of Ypsomed AG. To optimize communication between people with diabetes and healthcare professionals, mylife Therapy Management is an easy-to-use, easy-to-share solution for diabetes therapy data. mylife App by Ypsomed suffers from a security vulnerability that...

7.5CVSS1.5AI score0.01105EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/07/15 12:00 a.m.8 views

Nightscout Web Monitor 跨站脚本漏洞

Nightscout Web Monitor is an open source web monitor for healthcare that allows multiple caregivers to remotely view a patient's blood glucose data in real time. A security vulnerability exists in Nightscout Web Monitor a.k.a. cgm-remote-monitor 14.2.2 that allows XSS via a crafted x - forward -...

6.1CVSS6.2AI score0.00666EPSS
SaveExploits0References3
ICS
ICS
added 2021/07/15 12:00 a.m.103 views

ICSMA-21-196-01_Ypsomed mylife

1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Ypsomed Equipment: mylife Cloud, mylife Mobile Application Vulnerabilities: Insufficiently Protected Credentials, Not Using an Unpredictable IV with CBC Mode, Use of Hard-coded Credentials 2. RISK...

7.5CVSS6.6AI score0.01105EPSS
SaveExploits0References2
Rows per page
Query Builder