Lucene search
+L

3075 matches found

Cvelist
Cvelist
added 2026/08/11 5:7 p.m.28 views

CVE-2026-66802 Windows Device Health Attestation (DHA) Remote Code Execution Vulnerability

...

8.1CVSS0.00352EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2026/08/11 5:7 p.m.8 views

CVE-2026-66802 Windows Device Health Attestation (DHA) Remote Code Execution Vulnerability

...

8.1CVSS5.2AI score0.00352EPSS
SaveExploits0References1
Microsoft CVE
Microsoft CVE
added 2026/08/11 2:0 p.m.25 views

Windows Device Health Attestation (DHA) Remote Code Execution Vulnerability

Integer overflow or wraparound in Microsoft Azure Attestation service and Device Health Attestation Service allows an unauthorized attacker to execute code over a network...

8.1CVSS5.6AI score0.00445EPSS
SaveExploits0
Microsoft CVE
Microsoft CVE
added 2026/08/11 2:0 p.m.6 views

Windows Device Health Attestation (DHA) Remote Code Execution Vulnerability

Concurrent execution using shared resource with improper synchronization 'race condition' in Microsoft Azure Attestation service and Device Health Attestation Service allows an unauthorized attacker to execute code over a network...

8.1CVSS5.7AI score0.00352EPSS
SaveExploits0
Positive Technologies
Positive Technologies
added 2026/08/11 12:0 a.m.2 views

PT-2026-70702

Name of the Vulnerable Software and Affected Versions Microsoft Azure Attestation service affected versions not specified Device Health Attestation Service affected versions not specified Description A race condition exists in the Microsoft Azure Attestation service and Device Health Attestation...

8.1CVSS5.9AI score0.00352EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2026/08/11 12:0 a.m.4 views

PT-2026-70934

The distributed Mira Android APK v4.5.15.4 allows an attacker read/write access to reproductive health profiles from internet connected hosts, which could result in forgery, deletion, or destruction of health information...

9.3CVSS5.3AI score0.00241EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2026/08/11 12:0 a.m.3 views

PT-2026-70780

Name of the Vulnerable Software and Affected Versions Microsoft Azure Attestation service affected versions not specified Device Health Attestation Service affected versions not specified Description An integer overflow or wraparound occurs in the Microsoft Azure Attestation service and Device...

8.1CVSS5.7AI score0.00445EPSS
SaveExploits0References4
NVD
NVD
added 2026/08/10 9:17 a.m.9 views

CVE-2026-21082

Relative path traversal in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS0.00137EPSS
SaveExploits0References1
NVD
NVD
added 2026/08/10 9:17 a.m.10 views

CVE-2026-21077

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS0.00105EPSS
SaveExploits0References1
NVD
NVD
added 2026/08/10 9:17 a.m.10 views

CVE-2026-21076

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS0.00105EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/08/10 7:44 a.m.8 views

EUVD-2026-55107

Relative path traversal in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS5.2AI score0.00137EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/08/10 7:44 a.m.33 views

CVE-2026-21082

Relative path traversal in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS0.00137EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2026/08/10 7:44 a.m.8 views

CVE-2026-21082

Relative path traversal in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS5.2AI score0.00137EPSS
SaveExploits0References2
CVE
CVE
added 2026/08/10 7:44 a.m.43 views

CVE-2026-21082

The CVE-2026-21082 entry identifies a relative path traversal vulnerability in Samsung Health prior to version 7.0.0, allowing local attackers to access sensitive information. Affected software: Samsung Health (pre-7.0.0). Root cause: relative path traversal. Impact: confidentiality of data may b...

6.9CVSS5.2AI score0.00137EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/08/10 7:43 a.m.35 views

CVE-2026-21077

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS0.00105EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/08/10 7:43 a.m.8 views

EUVD-2026-55102

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS5.2AI score0.00105EPSS
SaveExploits0References1
CVE
CVE
added 2026/08/10 7:43 a.m.38 views

CVE-2026-21077

Samsung Health is affected by CVE-2026-21077 due to incorrect authorization prior to version 7.0.0, allowing local attackers to access sensitive information. Affected software: Samsung Health (versions

6.9CVSS5.2AI score0.00105EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2026/08/10 7:43 a.m.9 views

CVE-2026-21077

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS5.2AI score0.00105EPSS
SaveExploits0References2
CVE
CVE
added 2026/08/10 7:42 a.m.37 views

CVE-2026-21076

Samsung Health prior to version 7.0.0 has an incorrect authorization flaw that could allow local attackers to access sensitive information. Affected product: Samsung Health (pre-7.0.0). Root cause: improper access control enabling local access to data. Reported CVSS v4.0 base score 6.9 (MEDIUM) w...

6.9CVSS5.2AI score0.00105EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2026/08/10 7:42 a.m.8 views

CVE-2026-21076

Incorrect authorization in Samsung Health prior to version 7.0.0 allows local attackers to access sensitive information...

6.9CVSS5.2AI score0.00105EPSS
SaveExploits0References2
Rows per page
Query Builder