13510 matches found
PT-2021-22048 · Unknown · Integria Ims
Name of the Vulnerable Software and Affected Versions: Integria IMS affected versions not specified Description: The login check in Integria IMS uses a loose comparator to compare the MD5 hash of the user-provided password and the MD5 hash stored in the database. This allows an attacker with a...
CVE-2021-3833
Integria IMS login check uses a loose comparator "==" to compare the MD5 hash of the password provided by the user and the MD5 hash stored in the database. An attacker with a specific formatted password could exploit this vulnerability in order to login in the system with different passwords...
PT-2021-14727 · Jenkins · Jenkins +1
Name of the Vulnerable Software and Affected Versions: Jenkins Git Plugin versions 4.8.2 and earlier Description: The issue arises from the failure to escape Git SHA-1 checksum parameters provided to commit notifications when displayed in a build cause, resulting in a stored cross-site scripting...
in erikdubbelboer/phpredisadmin
Description $response is a salted md5 hash generated based on the concatenated hashed of credentials with other parameters. It has been discovered that $response compares with $data'response' using comparison operator != in file login.inc.php. This might cause unexpected behavior due to type...
in livehelperchat/livehelperchat
Description Sensitive data on the application can be exposed after the user logout Proof of Concept 1 Login to the application demo.livehelperchat.com/siteadmin/ 2 Go to page like My Account , or Any other page 3 Click logout 4 Click browser back button Impact When a user logs out without closing...
CVE-2021-38400
An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...
CVE-2021-23857
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system...
CVE-2021-23857
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system...
Hardcoded credentials
An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...
CVE-2021-23857
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system...
CVE-2021-38400 Use of Password Hash with Insufficient Computational Effort for Boston Scientific Zoom Latitude
An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...
CVE-2021-38400
CVE-2021-38400 affects Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) Model 3120. Vulnerability: password hash stored/used with insufficient computational effort, allowing a physically proximate attacker with access to remove the device’s hard drive or craft a USB to extract th...
CVE-2021-23857 Login with hash
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system...
CVE-2021-23857
CVE-2021-23857 affects Bosch Rexroth IndraMotion Mlc (networked system). The vulnerability allows login with a password hash instead of a password, per Red Hat advisory description, which can enable an attacker to authenticate without the correct password. This issue is linked to CVE-2021-23858, ...
CVE-2021-41593
Lightning Labs lnd before 0.13.3-beta allows loss of funds because of dust HTLC exposure...
CVE-2021-38400
An attacker with physical access to Boston Scientific Zoom Latitude Model 3120 can remove the hard disk drive or create a specially crafted USB to extract the password hash for brute force reverse engineering of the system password...
in opensourcepos/opensourcepos
Description The use == and != of might cause type juggling at the affected code if $row-hashversion == 1. Proof of Concept If the md5 sum of users password starts with 0e, then any input with md5 sum starting with 0e will result in true at statement $row-password == md5$password Impact This...
Boston Scientific Zoom Latitude
1. EXECUTIVE SUMMARY CVSS v3 6.9 ATTENTION: Low attack complexity Vendor: Boston Scientific Equipment: ZOOM LATITUDE Programmer/Recorder/Monitor Model 3120 Vulnerabilities: Use of Password Hash with Insufficient Computational Effort, Missing Protection Against Hardware Reverse Engineering Using...
Boston Scientific Zoom Latitude Programmer/Recorder/Monitor Model 3120 安全漏洞
The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is a portable cardiac rhythm management Crm programming system from Boston Scientific, Inc. The Boston Scientific ZOOM LATITUDE Programmer/Recorder/Monitor PRM Model 3120 is vulnerable to an encryption error that could...