13504 matches found
PT-2022-17545 · Amazon Web Services · Aws S3 Crypto Sdk
Name of the Vulnerable Software and Affected Versions: AWS S3 Crypto SDK affected versions not specified Description: The AWS S3 Crypto SDK sends an unencrypted hash of the plaintext alongside the ciphertext as a metadata field. This hash can be used to brute force the plaintext, if the hash is...
CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions V17 Update 2,...
CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions V17 Update 2,...
CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions V17 Update 2,...
CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions V17 Update 2,...
CVE-2021-40360
Siemens SIMATIC PCS 7 and SIMATIC WinCC contain a vulnerability (CVE-2021-40360) where the password hash of a local account on a remote server can be exposed via a public API, enabling an authenticated attacker to brute‑force and log in. Affected: PCS 7 v8.2–v9.1; WinCC v7.4–v7.5 and v15–v17 (wit...
PT-2022-4092 · Siemens · Simatic Pcs 7 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC PCS 7 versions V8.2 through V9.1 SIMATIC PCS 7 version V9.1 prior to V9.1 SP1 SIMATIC WinCC versions V7.4 through V7.4 prior to V7.4 SP1 Update 19 SIMATIC WinCC versions V7.5 through V7.5 prior to V7.5 SP2 Update 6 SIMATIC WinCC...
AlmaLinux 8 : openssl (ALSA-2021:4424)
The remote AlmaLinux 8 host has packages installed that are affected by multiple vulnerabilities as referenced in the ALSA-2021:4424 advisory. - Calls to EVPCipherUpdate, EVPEncryptUpdate and EVPDecryptUpdate may overflow the output length argument in some cases where the input length is close to...
Description of the security update for Office 2013: February 8, 2022 (KB5002146)
Description of the security update for Office 2013: February 8, 2022 KB5002146 Summary This security update resolves a Microsoft Office graphics remote code execution vulnerability. To learn more about the vulnerability, see Microsoft Common Vulnerabilities and Exposures CVE-2022-22003. Note: To...
Description of the security update for SharePoint Server Subscription Edition: February 8, 2022 (KB5002145)
None None...
Description of the security update for Office Web Apps Server 2013: February 8, 2022 (KB5002149)
None None...
Description of the security update for SharePoint Enterprise Server 2013: February 8, 2022 (KB5002147)
None None...
Description of the security update for SharePoint Enterprise Server 2016: February 8, 2022 (KB5002136)
None None...
Description of the security update for Office Online Server: February 8, 2022 (KB5002133)
None None...
Siemens SIMATIC 信息泄露漏洞
Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, Germany.SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. Siemens SIMATIC PCS 7 and SIMATIC WinCC have a security vulnerability that allows an authenticated...
Siemens SIMATIC PCS 7 and SIMATIC WinCC Information Disclosure Vulnerability
Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, Germany.SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. Siemens SIMATIC PCS 7 and SIMATIC WinCC have a security vulnerability that allows an authenticated...
Siemens SICAM MMU, SICAM T, and SICAM SGU Use of Password Hash with Insufficient Computational Effort (CVE-2020-10040)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with local access to the device might be able to retrieve some passwords in clear text. This plugin only works with Tenable.ot. Please visit...
CLSA-2022-1643727489 Fix of CVE: CVE-2021-23840, CVE-2021-3712, CVE-2021-23841
CVE-2021-3712: openssl: Read buffer overruns processing ASN.1 strings - CVE-2021-23840: openssl: integer overflow in CipherUpdate - CVE-2021-23841: openssl: NULL pointer dereference in X509issuerandserialhash...
Domain Escalation – Machine Accounts
The pass the hash technique is not new and it was usually used for lateral movement on the network in scenarios where the administrator password… Continue reading - Domain Escalation - Machine Accounts...
GHSA-RMR5-CPV2-VGJF Denial of Service by injecting highly recursive collections or maps in XStream
Impact The vulnerability may allow a remote attacker to allocate 100% CPU time on the target system depending on CPU type or parallel execution of such a payload resulting in a denial of service only by manipulating the processed input stream. Patches XStream 1.4.19 monitors and accumulates the...