8241 matches found
CVE-2014-3205
backupmgt/preconnectcheck.php in Seagate BlackArmor NAS contains a hard-coded password of '!@$$%FREDESWWSED' for a backdoor user...
CVE-2014-3205
The CVE-2014-3205 issue affects Seagate BlackArmor NAS in backupmgt/pre_connect_check.php, where a backdoor user is authenticated using a hard-coded password '!~@##$$%FREDESWWSED'. The vulnerability is documented across multiple sources (NVD entry, CNVD/CVE records, and CNVD Chinese advisory) and...
CVE-2014-3205
backupmgt/preconnectcheck.php in Seagate BlackArmor NAS contains a hard-coded password of '!@$$%FREDESWWSED' for a backdoor user...
Multiple IoT Vendors – Multiple Vulnerabilities
Vulnerabilities summary The following advisory describes three 3 vulnerabilities found in the following vendors: Lorex StarVedia Eminent Kraun The vulnerabilities found: Hard-coded credentials Remote command injection 2 It is possible to chain the vulnerabilities and to achieve unauthenticated...
CVE-2017-12726
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
Hardcoded credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
Hardcoded credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12726
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12726
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...
CVE-2017-12725
CVE-2017-12725 affects Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, versions 1.1, 1.5 and 1.6. The vulnerability stems from hard-coded credentials used to auto-establish a wireless connection with default network configuration, potentially enabling remote access. If the pump is E...
CVE-2017-12726
The CVE-2017-12726 vulnerability affects the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump (Versions 1.1, 1.5, 1.6). A hard-coded credential mechanism is used for Telnet, enabling remote access to the pump’s communications module when external network access is allowed. The issue i...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12724
CVE-2017-12724 affects Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump (firmware versions 1.1, 1.5, 1.6). The vulnerability stems from hard-coded credentials on the pump’s FTP server, which is only accessible when FTP is enabled, enabling unauthorized access to the device. The ICS-CE...
Dell EMC Patches Critical Flaws in VMAX Enterprise Storage Systems
Dell EMC fixed two critical flaws in its management interfaces for its VMAX enterprise storage systems. One of the vulnerabilities could allow a remote attacker to use a hard-coded password to a default account to gain unauthorized access to systems. The company issued updates that address the tw...
iBall iB-WRA150N Multiple Vulnerabilities
Exploit for hardware platform in category web applications Vulnerabilities summary The following advisory describes two 2 vulnerabilities found in iB-WRA150N devices, firmware 1.2.6 build 110401 Rel.47776n. iB-WRA150N is “a powerful solution to Internet connectivity at home, small offices and wor...