5646 matches found
CVE-2017-11632: Use of Hard-coded Credentials
An issue was discovered on Wireless IP Camera 360 devices. A root account with a known SHA-512 password hash exists, which makes it easier for remote attackers to obtain administrative access via a TELNET session...
CVE-2017-11634: Use of Hard-coded Credentials
An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456...
Multiple IoT Vendors – Multiple Vulnerabilities
Vulnerabilities summary The following advisory describes three 3 vulnerabilities found in the following vendors: Lorex StarVedia Eminent Kraun The vulnerabilities found: Hard-coded credentials Remote command injection 2 It is possible to chain the vulnerabilities and to achieve unauthenticated...
CVE-2014-3205: Use of Hard-coded Credentials
backupmgt/preconnectcheck.php in Seagate BlackArmor NAS contains a hard-coded password of '!@$$%FREDESWWSED' for a backdoor user...
CVE-2015-9254: Use of Hard-coded Credentials
Datto ALTO and SIRIS devices have a default VNC password...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
Hardcoded credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
Hardcoded credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12725
CVE-2017-12725 affects Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, versions 1.1, 1.5 and 1.6. The vulnerability stems from hard-coded credentials used to auto-establish a wireless connection with default network configuration, potentially enabling remote access. If the pump is E...
CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12724
CVE-2017-12724 affects Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump (firmware versions 1.1, 1.5, 1.6). The vulnerability stems from hard-coded credentials on the pump’s FTP server, which is only accessible when FTP is enabled, enabling unauthorized access to the device. The ICS-CE...
CVE-2017-12724: Use of Hard-coded Credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...
CVE-2017-12725: Use of Hard-coded Credentials
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...
CVE-2017-12726: Use of Hard-coded Credentials
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...
CVE-2018-1214: Use of Hard-coded Credentials
Dell EMC SupportAssist Enterprise version 1.1 creates a local Windows user account named "OMEAdapterUser" with a default password as part of the installation process. This unnecessary user account also remains even after an upgrade from v1.1 to v1.2. Access to the management console can be achiev...
CVE-2018-6825: Use of Hard-coded Credentials
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access...