Lucene search
K

6 matches found

OSV
OSV
added 2026/04/10 7:7 a.m.1 views

MAL-2026-2823 Malicious code in @genoma-ui/components (npm)

Malicious package detected. It uses pre/post install scripts to download/execute code and exfiltrate user data via curl from a hardcoded IP. --- -= Per source details. Do not edit below this line.=- Source: amazon-inspector a5fb9acd5bf2a73c82be9ac19b7c0cad285cfea2a4b6ff69655f61e7e4a0c26c The...

5.8AI score
Exploits0References1
VulnCheck KEV
VulnCheck KEV
added 2026/01/20 12:0 a.m.0 views

VulnCheck KEV: CVE-2025-0626

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS5.8AI score0.00084EPSS
In wildExploits0References2
OSV
OSV
added 2025/07/28 10:20 p.m.1 views

USN-7677-1 cloud-init vulnerabilities

Harry Sintonen discovered that the hotplugd socket in cloud-init was world writable. An attacker could possibly use this issue to send hotplug-hook commands. CVE-2024-11584 It was discovered that cloud-init granted root access to a hardcoded URL with a local IP address when a non-x86 platform is...

8.8CVSS5.8AI score0.0013EPSS
Exploits0References3
Packet Storm News
Packet Storm News
added 2025/01/31 12:0 a.m.2 views

CISA: Contec CMS8000 Contains a Backdoor

This fact sheet details an analysis of three firmware package versions of the Contec CMS8000, a patient monitor used by the U.S. Healthcare and Public Health HPH sector. Analysts discovered that an embedded backdoor function with a hard-coded IP address and functionality that enables patient data...

8.2CVSS7AI score0.00269EPSS
Exploits0
Positive Technologies
Positive Technologies
added 2025/01/21 12:0 a.m.2 views

PT-2025-3988 · Epsimed +1 · Epsimed Mn-120 Patient Monitor +1

Name of the Vulnerable Software and Affected Versions: Contec Health CMS8000 Patient Monitor affected versions not specified Epsimed MN-120 patient monitor affected versions not specified Description: The affected product sends out remote access requests to a hard-coded IP address, bypassing...

7.7CVSS9.5AI score0.00084EPSS
Exploits0References32
Code423n4
Code423n4
added 2023/09/11 12:0 a.m.11 views

The roerouter hard-coded address error causes all fee funds to be sent to the treasury instead of the vault

Lines of code Vulnerability details Impact The roerouter hard-coded address error causes all fee funds to be sent to the treasury instead of the vault. This will reduce the capital utilization rate, because the fee should be added to the LP to earn interest, but now because the vault address cann...

6.7AI score
Exploits0
Rows per page
Query Builder