8490 matches found
CVE-2023-30352
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed...
CVE-2023-30352
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed...
Hardcoded credentials
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for root which is stored using weak encryption. This vulnerability allows attackers to connect to the TELNET service or UART by using the exposed credentials...
CVE-2023-30351
CVE-2023-30351 affects Shenzen Tenda Technology IP Camera CP3, version 11.10.00.2211041355. The issue is a hard-coded default root password stored with weak encryption, enabling an attacker to authenticate via TELNET (or UART) using exposed credentials. The CVSS v3.1 base score is 7.5 (HIGH) with...
PT-2023-22647 · Shenzen Tenda Technology · Tenda Ip Camera Cp3
Name of the Vulnerable Software and Affected Versions: Shenzen Tenda Technology IP Camera CP3 version 11.10.00.2211041355 Description: The issue is related to a hard-coded default password for the root user, which is stored using weak encryption. This allows attackers to connect to the TELNET...
Tenda CP3 加密问题漏洞
Tenda CP3 is a smart camera from Tenda China. A security vulnerability exists in the Tenda CP3 version V11.10.00.2211041355, which stems from the device containing a hard-coded default root password that is stored using weak encryption, and can be exploited by an attacker to connect to a TELNET...
CVE-2023-30354
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access...
CVE-2023-30352
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed...
Siemens SIMATIC Cloud Connect 7 Using Hardcoded Passwords Vulnerability
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. Siemens SIMATIC Cloud Connect 7 suffers from a use of hard-coded password vulnerability that could be...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-29103
The CVE-2023-29103 entry concerns Siemens SIMATIC Cloud Connect 7 CC712/CC716 with versions 2.0–2.1, where a hard-coded password protects diagnostic files, enabling an authenticated attacker to access protected data. Red Hat and NVD entries corroborate the affected products and vulnerability clas...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
Siemens SIMATIC Cloud Connect 7
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SIMATIC Cloud Connect 安全漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. Siemens SIMATIC Cloud Connect 7 suffers from a use of hard-coded password vulnerability that could be...
PT-2023-22151 · Siemens · Simatic Cloud Connect 7 Cc712 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description: A vulnerability has been identified where the affected device uses a hard-coded password to protect diagnostic files...
JINS MEME CORE uses a hard-coded cryptographic key
Overview JINS MEME CORE provided by JINS Inc. is a nose pad type sensor attached to a glass frame. JINS MEME CORE uses a hard-coded cryptographic key CWE-321. MASAHIRO IIDA of LAC Co.,Ltd. reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Earl...
JVN#13306058: JINS MEME CORE uses a hard-coded cryptographic key
JINS MEME CORE provided by JINS Inc. is a nose pad type sensor attached to a glass frame. JINS MEME CORE uses a hard-coded cryptographic key CWE-321. Impact A network-adjacent attacker may decrypt data acquired by a sensor of the affected product. Solution Update the firmware Update the firmware ...
CVE-2023-26203
A use of hard-coded credentials vulnerability CWE-798 in FortiNAC-F version 7.2.0, FortiNAC version 9.4.2 and below, 9.2 all versions, 9.1 all versions, 8.8 all versions, 8.7 all versions may allow an authenticated attacker to access to the database via shell commands...