•added 2025/01/15 12:00 a.m.•3 views

CVE-2024-48126: Use of Hard-coded Credentials

HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...

9.8CVSS5.7AI score0.00409EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•5 views

CVE-2024-48121: Cleartext Transmission of Sensitive Information

The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...

6.5CVSS5.8AI score0.00222EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/01/15 12:00 a.m.•5 views

PT-2025-2791

Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I affected versions not specified Description: An issue in the AsDB service allows attackers to enumerate user credentials via crafted GIOP protocol requests. This issue affects the HI-SCAN 6040i Hitrax HX-03-19-...

7.5CVSS0.00373EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2025/01/15 12:00 a.m.•6 views

PT-2025-2788

Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I affected versions not specified Description: The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to...

6.5CVSS0.00222EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2025/01/15 12:00 a.m.•13 views

Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞

The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from the inclusion of hard-coded credentials used to access...

9.8CVSS6.7AI score0.00409EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/15 12:00 a.m.•13 views

Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞

The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from a problem with the USB autorun feature...

8.4CVSS6.8AI score0.00177EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•2 views

CVE-2024-48122: Initialization of a Resource with an Insecure Default

Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...

6.7CVSS5.8AI score0.00166EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/01/15 12:00 a.m.•6 views

PT-2025-2790

Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I affected versions not specified Description: An issue in the USB Autorun function allows attackers to execute arbitrary code via uploading a crafted script from a USB device. Recommendations: At the moment, the...

8.4CVSS0.00177EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2025/01/15 12:00 a.m.•4 views

PT-2025-2789

Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I affected versions not specified Description: The issue concerns insecure default configurations that allow authenticated attackers with low-level privileges to escalate to root-level privileges. Recommendations...

6.7CVSS0.00166EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•5 views

CVE-2024-48123: Untrusted Search Path

An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...

8.4CVSS6.5AI score0.00177EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/15 12:00 a.m.•6 views

CVE-2024-48125: Exposure of Sensitive Information to an Unauthorized Actor

An issue in the AsDB service of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to enumerate user credentials via crafted GIOP protocol requests...