Lucene search
+L

8646 matches found

NVD
NVD
•added 2025/04/15 10:15 p.m.•37 views

CVE-2025-31654

An attacker can get information about the groups of the smart home devices for arbitrary users i.e., "rooms"...

6.9CVSS0.00296EPSS
SaveExploits0References1
OSV
OSV
•added 2025/04/15 10:15 p.m.•18 views

CVE-2025-31654

An attacker can get information about the groups of the smart home devices for arbitrary users i.e., "rooms"...

6.9CVSS5.9AI score0.00296EPSS
SaveExploits0References1
NVD
NVD
•added 2025/04/15 10:15 p.m.•12 views

CVE-2025-26930

Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in alleythemes Home Services home-services allows DOM-Based XSS.This issue affects Home Services: from n/a through = 1.2.6...

6.5CVSS0.00269EPSS
SaveExploits0References1
CVE
CVE
•added 2025/04/15 9:53 p.m.•55 views

CVE-2025-26930

CVE-2025-26930 describes a DOM-based XSS in the alleythemes Home Services WordPress plugin, affecting versions

6.5CVSS6.9AI score0.00269EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/04/15 9:53 p.m.•6 views

CVE-2025-26930 WordPress Home Services plugin <= 1.2.6 - Cross Site Scripting (XSS) vulnerability

Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in alleythemes Home Services home-services allows DOM-Based XSS.This issue affects Home Services: from n/a through = 1.2.6...

6.5CVSS7.2AI score0.00269EPSS
SaveExploits0References1
CVE
CVE
•added 2025/04/15 9:07 p.m.•84 views

CVE-2025-31654

CVE-2025-31654 concerns Growatt Cloud Applications where an attacker can obtain information about the groups of smart home devices for arbitrary users (i.e., the users’ “rooms”). The CVE appears across multiple sources (NVD, Red Hat, CVE List, CVSS metrics) and is associated with the Growatt clou...

6.9CVSS5.3AI score0.00296EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2025/04/15 9:07 p.m.•14 views

CVE-2025-31654 Growatt Cloud portal Authorization Bypass Through User-Controlled Key

An attacker can get information about the groups of the smart home devices for arbitrary users i.e., "rooms"...

6.9CVSS5.7AI score0.00296EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/04/15 9:07 p.m.•41 views

CVE-2025-31654 Growatt Cloud portal Authorization Bypass Through User-Controlled Key

An attacker can get information about the groups of the smart home devices for arbitrary users i.e., "rooms"...

6.9CVSS0.00296EPSS
SaveExploits0References1
NVD
NVD
•added 2025/04/15 6:15 p.m.•25 views

CVE-2021-27289

A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12, where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attack...

9.1CVSS0.00854EPSS
SaveExploits1References6
CNNVD
CNNVD
•added 2025/04/15 12:00 a.m.•23 views

Growatt Cloud Applications 安全漏洞

Growatt Cloud Applications is a monitoring platform from Growatt, a Chinese company. A security vulnerability exists in Growatt Cloud Applications version 3.6.0 and earlier, which stems from an attacker's ability to gain access to any user's smart home device group information...

6.9CVSS6.7AI score0.00296EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/04/15 12:00 a.m.•14 views

WordPress plugin Home Services 跨站脚本漏洞

WordPress and WordPress plugin are both products of the WordPress Foundation.WordPress is a blogging platform developed in the PHP language. The platform supports setting up personal blog sites on servers with PHP and MySQL.WordPress plugin is an application plugin. A cross-site scripting...

6.5CVSS6.6AI score0.00269EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/04/15 12:00 a.m.•7 views

CVE-2021-27289: Authentication Bypass by Capture-replay

A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12, where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attack...

9.1CVSS5.7AI score0.00854EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/04/15 12:00 a.m.•3 views

CVE-2025-26930: Improper Neutralization of Input During Web Page Generation

Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in alleythemes Home Services home-services allows DOM-Based XSS.This issue affects Home Services: from n/a through = 1.2.6...

6.5CVSS6.7AI score0.00269EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/04/15 12:00 a.m.•5 views

CVE-2025-32993: Improper Neutralization of Special Elements used in an SQL Command

Vision Helpdesk through 5.7.0 allows Time-Based Blind SQL injection via the Forgot Password aka index.php?/home/forgot-password visusername parameter. Authentication is not needed...

6.5CVSS5.8AI score0.00274EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/04/15 12:00 a.m.•29 views

PT-2025-16493 · Growatt · Cloud Portal

Name of the Vulnerable Software and Affected Versions: The product name cannot be determined. Description: An attacker can obtain information about the groups of smart home devices for arbitrary users, referred to as "rooms". Recommendations: At the moment, there is no information about a newer...

6.9CVSS6.3AI score0.00296EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2025/04/15 12:00 a.m.•31 views

CVE-2021-27289

A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12, where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attack...

0.00854EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
•added 2025/04/15 12:00 a.m.•16 views

PT-2025-16521 · Unknown · Alleythemes Home Services

Name of the Vulnerable Software and Affected Versions: alleythemes Home Services versions 1.2.6 and earlier Description: The issue is related to improper neutralization of input during web page generation, which allows for DOM-Based XSS. This enables potential attackers to inject malicious script...

6.5CVSS7AI score0.00269EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2025/04/15 12:00 a.m.•4 views

PT-2025-16370

Name of the Vulnerable Software and Affected Versions Ksix Zigbee smart home kit versions v1.0.3 through v1.0.12 Description A replay attack issue was discovered in the Zigbee smart home kit, where the anti-replay mechanism based on the frame counter field is improperly implemented. This allows a...

9.1CVSS5.7AI score0.00854EPSS
SaveExploits1References9
RedhatCVE
RedhatCVE
•added 2025/04/09 6:05 p.m.•23 views

CVE-2025-3351

A vulnerability has been found in PHPGurukul Old Age Home Management System 1.0 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /admin/login.php. The manipulation of the argument Username leads to sql injection. The attack can be launched remotel...

9.8CVSS7.4AI score0.00508EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/04/09 6:05 p.m.•21 views

CVE-2025-3352

A vulnerability was found in PHPGurukul Old Age Home Management System 1.0 and classified as critical. Affected by this issue is some unknown functionality of the file /admin/edit-scdetails.php. The manipulation of the argument contnum leads to sql injection. The attack may be launched remotely...

9.8CVSS7.4AI score0.00508EPSS
SaveExploits0References1
Rows per page
Query Builder