2232 matches found
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...
CVE-2020-6992
GE Digital CIMPLICITY HMI/SCADA vulnerability CVE-2020-6992 affects CIMPLICITY v10.0 and earlier. It is a local privilege escalation (CWE-269) that requires an authenticated session to modify the system and arbitrarily execute code. Affected component: CIMPLICITY HMI/SCADA software; root cause is...
Authentication flaw
VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HM...
CVE-2020-7000
VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HM...
Advantech WebAccess Buffer Overflow Vulnerability (CNVD-2020-19926)
Advantech WebAccess is a set of HMI/SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphic display and real-time data control, and provides remote control and management of automation equipment. A buffer overflow vulnerability exists in...
Advantech WebAccess
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: WebAccess Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability may allow remote code execution. 3. TECHNICAL DETAILS 3.1...
Nanda Aotuo Technology NA-VIEW V1.02.4 suffers from denial of service vulnerability (CNVD-2020-21835)
NA-VIEW is a touch screen configuration software. NA-VIEW V1.02.4 has a denial of service vulnerability that can be exploited by attackers to construct malformed HMI files that can crash the program...
Memory Corruption Vulnerability in Taian Technology AT Upper (AT HMI System) (CNVD-2020-22761)
Ltd. is a wholly foreign owned enterprise established in China on July 1, 2000 by Antai International Investment Singapore Pte Ltd, a subsidiary of TECO Group, a renowned Taiwanese multinational corporation. A memory corruption vulnerability exists in Taiwan Security Technology's AT Upper Unit AT...
Schneider Electric Magelis HMI Panels
1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Magelis HMI Panel Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...
CVE-2020-7052
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...
CVE-2020-7052
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...
Race condition
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...
CVE-2020-7052
CVE-2020-7052 affects CODESYS Control V3, Gateway V3 and HMI V3 before 3.5.15.30. The issue is uncontrolled memory allocation that can lead to a remote denial of service. The connected sources reiterate the same affected products and condition; no explicit patch/version details are provided in th...
CVE-2020-7052
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition...
Pwn2Own Miami Contestants Haul in $180K for Hacking ICS Equipment
The very first Pwn2Own hacking competition that exclusively focuses on the industrial control systems ICS has kicked off in Miami. So far, a total of $180,000 has been awarded for pwning five different products. The contest hosts at Trend Micro’s Zero Day initiative ZDI have allocated more than...
CVE-2019-10995
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface...
CVE-2019-10995
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface...
CVE-2019-10995
The CVE-2019-10995 issue affects ABB CP651 HMI family (including CP651, CP651-WEB, CP661, CP661-WEB, CP665, CP665-WEB, CP676, CP676-WEB) with BSP UN30 v1.76 and earlier. It stems from hidden administrative accounts used during provisioning, enabling privileged access that can lead to arbitrary co...
CVE-2019-10995
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface...
Siemens SINAMICS PERFECT HARMONY GH180
1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Vulnerability: Protection Mechanism Failure 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized attacker with physical access...