2207 matches found
mySCADA myPRO OS Command Injection Vulnerability (CNVD-2023-38197)
mySCADA myPRO is a software application. myPRO is a professional HMI/SCADA system designed primarily for the visualization and control of industrial processes. An operating system command injection vulnerability exists in mySCADA myPRO 8.26.0 and earlier versions, which can be exploited by an...
Scada-LTS Third Party Component
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Scada-LTS Equipment: Scada-LTS Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow loss of sensitive...
The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software lies in the lack of security measures taken to protect the SQL query structure, allowing a hacker to execute arbitrary code.
The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software is related to the lack of protective measures for the SQL query structure. Exploiting this vulnerability could allow an attacker to execute...
CVE-2023-1552
ToolboxST prior to version 7.10 is affected by a deserialization vulnerability. An attacker with local access to an HMI or who has conducted a social engineering attack on an authorized operator could execute code in a Toolbox user's context through the deserialization of an untrusted configurati...
Contec CONPROSYS HMI System (CHS) SQL Injection (CVE-2023-1658)
Binary data contecchscve-2023-1658.nbin...
The vulnerability of HMI/SCADA CONPROSYS HMI lies in the lack of protective measures for SQL query structures, allowing attackers to gain unauthorized access to protected information.
The vulnerability of HMI/SCADA CONPROSYS HMI lies in the lack of measures taken to protect the SQL query structure. Exploiting this vulnerability can allow an attacker, operating remotely, to gain unauthorized access to protected information by sending specially crafted SQL queries to the databas...
CONPROSYS HMI System(CHS) vulnerable to SQL injection
Overview CONPROSYS HMI SystemCHS provided by Contec Co., Ltd. contains an SQL injection vulnerability CWE-89, CVE-2023-1658. Tenable Network Security reported this vulnerability to the developer. JPCERT/CC coordinated with the reporter and the developer. Impact Sending a specially crafted paramet...
The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software allows a perpetrator to execute arbitrary codes.
The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software is related to improper project conversion. Exploiting this vulnerability could allow an attacker to execute arbitrary code...
PT-2023-2083 · Unknown · Conprosys Hmi
Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI affected versions not specified Description: The issue is related to the lack of protection for the SQL query structure, allowing a remote attacker to gain unauthorized access to protected information by sending specially crafte...
ABB (CVE-2019-7229)
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: Utilization of USB/SD Card to flash the device and Remote provisioning process via ABB Panel Builder 600 over FTP. Neither of these transmission methods implements any form of encryption...
ABB Central Licensing System Improper Access Control (CVE-2020-8471)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB Central Licensing System Uncontrolled Resource Consumption (CVE-2020-8475)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB Central Licensing System Permissions, Privileges, and Access Controls (CVE-2020-8476)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB Central Licensing System Improper Restriction of XML External Entity Reference (CVE-2020-8479)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
CVE-2023-0598
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...
CVE-2023-0598
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...
Path traversal
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...
CVE-2023-0598 GE Digital Proficy Code Injection
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...
CVE-2023-0598
GE Digital Proficy iFIX (2022, v6.1, v6.5) are affected by CVE-2023-0598 due to improper generation of code (CWE-94). An attacker could insert malicious configuration files in the web server execution path and gain full control of the HMI software. ICSA-23-073-03 lists the affected products and n...
GE iFIX 代码注入漏洞
GE iFIX is General Electric's GE platform for improving productivity and process control through industrial-grade SCADA and high-performance HMI. A code injection vulnerability exists in GE iFIX. An attacker could use this vulnerability to insert a malicious configuration file into the intended w...