2207 matches found
CVE-2020-10920
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port...
CVE-2024-12399
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication...
CVE-2024-11999
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product...
CVE-2025-0960
AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device...
CVE-2025-0960 AutomationDirect C-more EA9 HMI Classic Buffer Overflow
AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device...
CVE-2025-0960
The CVE-2025-0960 entry affects AutomationDirect C-more EA9 HMI. A function contains bounds checks that can be skipped, enabling an attacker to cause a denial-of-service or potentially achieve remote code execution on the affected device. The issue is network-exploitable with high impact to confi...
AutomationDirect C-more EA9 HMI
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or achieve remote code execution on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...
AutomationDirect C-more EA9 HMI 安全漏洞
AutomationDirect C-MORE EA9 HMI is a touchscreen from AutomationDirect, Inc. A security vulnerability exists in the AutomationDirect C-more EA9 HMI that originates from a boundary check skip resulting in a buffer overflow...
Schneider Electric Pro-face GP-Pro EX和Remote HMI 安全漏洞
Schneider Electric Pro-face GP-Pro EX and Schneider Electric Pro-face Remote HMI are both products of Schneider Electric, France.Schneider Electric Pro-face GP-Pro EX is an HMI operation management system. Schneider Electric Pro-face GP- EX is a human-machine interface operator management system,...
CVE-2024-11999
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product...
CVE-2024-11999
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product...
PT-2024-17393 · Schneider Electric · Schneider Electric
Name of the Vulnerable Software and Affected Versions: Schneider Electric products affected versions not specified Description: A Use of Unmaintained Third-Party Components issue exists that could allow complete control of the device when an authenticated user installs malicious code into an HMI...
PT-2024-10223 · Pro Face · Pro-Face Remote Hmi +1
Name of the Vulnerable Software and Affected Versions: Pro-Face GP-Pro EX affected versions not specified Pro-face Remote HMI affected versions not specified Description: The issue is related to an improper enforcement of message integrity during transmission in a communication channel, which cou...
Schneider Electric Harmony HMI and Pro-Face HMI Products
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
The vulnerability of the HMI interface configuration software Monitouch V-SFT lies in the possibility of operations going beyond the buffer boundaries in memory, allowing an attacker to execute arbitrary code.
The vulnerability of the HMI interface configuration software Monitouch V-SFT lies in the execution of operations beyond the buffer boundaries in memory. Exploiting this vulnerability allows an attacker to execute arbitrary code using specially created X1 files...
The vulnerability of the HMI interface configuration software Monitouch V-SFT lies in the possibility of operations going beyond the buffer boundaries in memory, allowing an attacker to execute arbitrary code.
The vulnerability of the HMI interface configuration software Monitouch V-SFT lies in the execution of operations beyond the buffer boundaries in memory. Exploiting this vulnerability allows an attacker to execute arbitrary code using specially created V9C files...
The vulnerability of the HMI interface configuration software Monitouch V-SFT lies in the possibility of buffer overflow due to a stack-based mechanism. This allows an attacker to execute arbitrary code.
The vulnerability of the HMI interface configuration software Monitouch V-SFT is related to the possibility of buffer overflow based on a stack. Exploiting this vulnerability could allow an attacker to execute arbitrary code using specially created V8 files...
Fuji Electric Monitouch V-SFT 安全漏洞
Fuji Electric Monitouch V-SFT is a configuration software for Human Machine Interfaces HMI provided by Fuji Electric. Fuji Electric Monitouch V-SFT suffers from a buffer overflow vulnerability that originates from not properly validating the length of user-supplied data before copying it into a...
CVE-2024-10313
iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or...
CVE-2024-10313 iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal
iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or...