Lucene search
+L

2232 matches found

CNVD
CNVD
added 2015/01/22 12:00 a.m.8 views

Schneider Electric ETG3000 FactoryCast HMI Gateway FTP Built-in Password Vulnerability

The Schneider Electric ETG3000 FactoryCast HMI Gateway is a new intelligent Web gateway. A default account vulnerability exists in the Schneider Electric ETG3000 FactoryCast HMI Gateway FTP server, allowing an attacker to access the service without authentication...

10CVSS6.9AI score0.04193EPSS
SaveExploits0References1
Prion
Prion
added 2015/01/17 2:59 a.m.23 views

Code injection

The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...

6.9CVSS7.3AI score0.00645EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2015/01/17 2:59 a.m.24 views

CVE-2014-2355

The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...

6.9CVSS6.8AI score0.00645EPSS
SaveExploits0References2
CVE
CVE
added 2015/01/17 2:00 a.m.51 views

CVE-2014-2355

The CVE-2014-2355 vulnerability affects GE Proficy HMI/SCADA–CIMPLICITY CimView and CimEdit components (versions 8.2 and earlier). The issue is a memory access violation when processing CIMPLICITY screen files (.CIM), potentially enabling privilege escalation within the application. Publicly disc...

6.9CVSS7AI score0.00645EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2015/01/17 2:00 a.m.30 views

CVE-2014-2355 GE Proficy HMI/SCADA CIMPLICITY CimView

The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...

6.6CVSS6.8AI score0.00645EPSS
SaveExploits0References1
ICS
ICS
added 2015/01/10 7:00 a.m.82 views

Siemens SIMATIC HMI Devices Vulnerabilities (Update E)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-099-01D Siemens SIMATIC HMI Devices Vulnerabilities that was published September 10, 2015, on the NCCIC/ICS‑CERT web site. Siemens has identified three vulnerabilities in its SIMATIC HMI devices. These...

6.8CVSS6.5AI score0.02134EPSS
SaveExploits0References10
Check Point Advisories
Check Point Advisories
added 2014/12/28 12:00 a.m.27 views

Advantech WebAccess HMI and SCADA Software CrossSite Scripting - Ver2 (CVE-2012-0233)

A cross-site scripting vulnerability has been reported in Advantech Webaccess. Successful exploitation of this vulnerability would allow remote attackers to inject arbitrary web script into the affected system...

4.3CVSS5.8AI score0.00989EPSS
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2014/12/28 12:00 a.m.46 views

Procyon Core Server HMI Memory Corruption SCADA Remote Code Execution - Ver2 (CVE-2011-3322)

A remote stack overflow vulnerability has been reported in Procyon Core Server HMI service. The vulnerability is due to a boundary check error. A remote attacker may exploit this issue by sending specially crafted messages to the target server. Successful exploitation could allow an attacker to...

10CVSS3.7AI score0.64653EPSS
SaveExploits5
n0where
n0where
added 2014/12/18 5:04 p.m.36 views

CONPOT ICS SCADA Honeypot

CONPOT ICS SCADA Honeypot Conpot is a low interactive server side Industrial Control Systems honeypot designed to be easy to deploy, modify and extend. By providing a range of common industrial control protocols we created the basics to build your own system, capable to emulate complex...

0.8AI score
SaveExploits0References1
myhack58
myhack58
added 2014/12/18 12:00 a.m.29 views

Industrial safety: BlackEnergy(dark)the use of the Siemens WinCC system has been repaired loopholes to launch attacks-vulnerability warning-the black bar safety net

Researchers recently found that the malware BlackEnergy(dark forces are using Siemens SIMATIC WinCC(Siemens the most classic process monitoring system has been repaired loopholes to re-attack the SCADA HMI system. ! Comeback: the BlackEnergy then update the BlackEnergy(dark)is an automated networ...

2.7AI score
SaveExploits0
ThreatPost
ThreatPost
added 2014/12/03 10:56 a.m.24 views

Elipse SCADA Denial of Service Patch

Brazilian process management software developer Elipse has patched a serious denial-of-service vulnerability in its web-based Elipse SCADA application. The software is used in a number of critical industries worldwide, including manufacturing, energy, water and wastewater plants. The vulnerabilit...

8.3AI score
SaveExploits0References11
zdt
zdt
added 2014/11/20 12:00 a.m.66 views

Advantech WebAccess 7.2 Stack-Based Buffer Overflow Vulnerability

Advantech WebAccess version 7.2 is vulnerable to a stack-based buffer overflow attack, which can be exploited by remote attackers to execute arbitrary code, by providing a malicious html file with specific parameters for an ActiveX component. Advantech WebAccess Stack-based Buffer Overflow 1...

7.2CVSS7.5AI score0.01051EPSS
SaveExploits1
Core Security
Core Security
added 2014/11/19 12:00 a.m.533 views

Advantech AdamView Buffer Overflow

Advisory ID Internal CORE-2014-0008 1. Advisory Information Title: Advantech AdamView Buffer Overflow Advisory ID: CORE-2014-0008 Advisory URL:http://www.coresecurity.com/advisories/advantech-adamview-buffer-overflow Date published: 2014-11-19 Date of last update: 2014-11-19 Vendors contacted:...

7.5CVSS7.6AI score0.05921EPSS
SaveExploits7
ThreatPost
ThreatPost
added 2014/10/29 10:25 a.m.78 views

BlackEnergy Malware Used in Attacks Against ICS HMI

Industrial control system operations running human-machine interface software from a handful of vendors are being targeted by a hacking campaign making use of the BlackEnergy malware. The United States Industrial Control System Cyber Emergency Response Team ICS-CERT published an advisory on Tuesd...

9.3CVSS8.1AI score0.81628EPSS
SaveExploits26References5
ThreatPost
ThreatPost
added 2014/10/07 2:49 p.m.30 views

Siemens Patches Five Vulnerabilities in SIMATIC WinCC for PCS 7

Siemens has patched five vulnerabilities in its SIMATIC PCS 7 system that could result in privilege escalation and give an attacker unauthenticated access to sensitive data. The flaws technically exist in WinCC, a SCADA supervisory control and data acquisition and HMI human-machine interface syst...

6CVSS0.5AI score0.01686EPSS
SaveExploits0References1
NVD
NVD
added 2014/07/24 2:55 p.m.20 views

CVE-2014-2370

Cross-site scripting XSS vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data...

4CVSS5.3AI score0.01362EPSS
SaveExploits0References4
Prion
Prion
added 2014/07/24 2:55 p.m.23 views

Cross site scripting

Cross-site scripting XSS vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data...

3.5CVSS5.7AI score0.01362EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2014/07/24 2:55 p.m.20 views

Cross site request forgery (csrf)

Cross-site request forgery CSRF vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors...

6CVSS7.2AI score0.00592EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2014/07/24 2:00 p.m.33 views

CVE-2014-2370 Omron NS Series HMI Improper Neutralization of Input During Web Page Generation

Cross-site scripting XSS vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data...

4CVSS5.3AI score0.01362EPSS
SaveExploits0References2
CVE
CVE
added 2014/07/24 2:00 p.m.51 views

CVE-2014-2369

Summary (CVE-2014-2369) CSRF vulnerability in Omron NS series HMI terminals (NS5/NS8/NS10/NS12/NS15; firmware 8.1xx–8.68x) could allow a remote authenticated attacker to hijack a victim’s session. Root cause: inadequate request verification in the web application (CWE-352). CVSSv2 base scores: NV...

6CVSS6.9AI score0.00592EPSS
SaveExploits0References3Affected Software6
Rows per page
Query Builder