Lucene search
+L

2232 matches found

CVE
CVE
added 2017/12/20 7:00 p.m.54 views

CVE-2017-16717

The CVE-2017-16717 entry affects WECON LeviStudio HMI (heap-based buffer overflow in LeviStudio HMI/Driver handling of project data) that may allow remote code execution. Public docs (ZDI-17-1001) specify exploitation requires user interaction (visiting a malicious page or opening a malicious fil...

9CVSS9.1AI score0.01945EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2017/12/20 7:00 p.m.23 views

CVE-2017-16717

A Heap-based Buffer Overflow issue was discovered in WECON LeviStudio HMI. The heap-based buffer overflow vulnerability has been identified, which may allow remote code execution...

9.1AI score0.01945EPSS
SaveExploits0References1
ICS
ICS
added 2017/12/19 12:00 a.m.71 views

Ecava IntegraXor

CVSS v3 5.3 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Ecava Equipment: IntegraXor Vulnerabilities: SQL Injection AFFECTED PRODUCTS The following version of IntegraXor, a web SCADA/HMI solution, is affected: Ecava IntegraXor v 6.1.1030.1 and prior. IMPACT Successful...

5.3CVSS6.1AI score0.01017EPSS
SaveExploits0References3
ICS
ICS
added 2017/12/19 12:00 a.m.46 views

WECON Technology Co., Ltd. LeviStudio HMI Editor

CVSS v3 7.3 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: WECON Technology Co., Ltd. WECON Equipment: LeviStudio HMI editor Vulnerability: Heap-based Buffer Overflow AFFECTED PRODUCTS All versions of LeviStudio HMI, an HMI editor, are affected. IMPACT Successful exploitation...

9CVSS9.1AI score0.01945EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2017/12/04 12:00 a.m.12 views

The vulnerability of Schneider Electric InTouch Machine Edition and InduSoft Web Studio HMI/SCADA systems lies in their authentication procedures, which allow attackers to execute arbitrary commands and gain full control over the server.

The vulnerability of Schneider Electric InTouch Machine Edition and InduSoft Web Studio HMI/SCADA systems is related to deficiencies in the authentication process for HMI clients. Exploiting this vulnerability allows a malicious actor to bypass the authentication process, execute arbitrary...

10CVSS8.1AI score0.05053EPSS
SaveExploits0References3
CNVD
CNVD
added 2017/11/13 12:00 a.m.11 views

Schneider Electric InduSoft Web Studio and InTouch Machine Edition Buffer Overflow Vulnerability

Schneider Electric InduSoft Web Studio and InTouch Machine Edition are both an embedded HMI software package from Schneider Electric France. A buffer overflow vulnerability exists in Schneider Electric InduSoft Web Studio and InTouch Machine Edition that could allow an attacker to remotely execut...

10CVSS7.5AI score0.05834EPSS
SaveExploits0References1
ICS
ICS
added 2017/11/02 12:00 a.m.54 views

Advantech WebAccess

CVSS v3 7.3 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Advantech Equipment: WebAccess Vulnerabilities: Stack-based Buffer Overflow, Untrusted Pointer Dereference AFFECTED PRODUCTS The following versions of WebAccess, an HMI platform, are affected: WebAccess versions prior...

6.8CVSS7.6AI score0.16043EPSS
SaveExploits4References3
zdt
zdt
added 2017/11/01 12:00 a.m.100 views

Progea Movicon 11.5.1181 Search Path Issues Vulnerability

Progea Movicon versions 11.5.1181 and below suffer from search path related vulnerabilities. Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element Advisory URL...

4.6CVSS7.2AI score0.00671EPSS
SaveExploits2
Packet Storm
Packet Storm
added 2017/10/31 12:00 a.m.98 views

Progea Movicon 11.5.1181 Search Path Issues

Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element Advisory URL https://ipositivesecurity.com/2017/10/28/ics-progea-movicon-scadahmi-vulnerabilities/ ICS-CERT Advisory https://ics-cert.us-cert.gov/advisories/ICSA-17-290-01...

7.1AI score0.00671EPSS
SaveExploits2
OSV
OSV
added 2017/10/17 10:29 p.m.11 views

CVE-2017-13999

A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memory; the attacker may then be able to crash the...

9.8CVSS6.2AI score0.02772EPSS
SaveExploits0References3
Prion
Prion
added 2017/10/17 10:29 p.m.20 views

Stack overflow

A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memory; the attacker may then be able to crash the...

7.5CVSS9.8AI score0.02772EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2017/10/17 10:00 p.m.62 views

CVE-2017-13999

Affected software : LEVI Studio HMI Editor (WECON) v1.8.1 and earlier. Vulnerability : Stack-based buffer overflow where the app does not verify string size before copying to memory, potentially crashing the app or allowing arbitrary code execution. Impact : Denial of service and arbitrary code e...

9.8CVSS9.7AI score0.02772EPSS
SaveExploits0References3Affected Software1
ICS
ICS
added 2017/10/17 12:00 a.m.45 views

Progea Movicon SCADA/HMI

CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Progea Equipment: Movicon SCADA/HMI Vulnerability: Uncontrolled Search Path Element, Unquoted Search Path or Element AFFECTED PRODUCTS The following versions of Movicon HMI, an HMI software platform, are affected:...

7.8CVSS8.4AI score0.00671EPSS
SaveExploits2References3
ICS
ICS
added 2017/10/12 12:00 a.m.84 views

WECON Technology Co., Ltd. LeviStudio HMI Editor

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: WECON Technology Co., Ltd. WECON Equipment: LeviStudio HMI Editor Vulnerabilities: Stack-based Buffer Overflow AFFECTED PRODUCTS The following versions of LEVI Studio HMI Editor, an HMI programming software product, a...

9.8CVSS10AI score0.02772EPSS
SaveExploits0References3
OSV
OSV
added 2017/10/05 1:29 a.m.9 views

CVE-2017-13995

An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables...

10CVSS5.8AI score0.02466EPSS
SaveExploits0References2
NVD
NVD
added 2017/10/05 1:29 a.m.35 views

CVE-2017-13995

An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables...

10CVSS9.2AI score0.02466EPSS
SaveExploits0References2
Prion
Prion
added 2017/10/05 1:29 a.m.29 views

Authentication flaw

An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables...

7.5CVSS9.1AI score0.02466EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2017/10/05 12:00 a.m.44 views

GE CIMPLICITY

CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow AFFECTED PRODUCTS The following versions of CIMPLICITY, an HMI/SCADA management platform, are affected: CIMPLICITY Versions 9.0 and prior. IMPACT...

6.8CVSS1AI score0.0075EPSS
SaveExploits0References27
ICS
ICS
added 2017/10/05 12:00 a.m.47 views

GE CIMPLICITY (Update A)

CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow UPDATED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-278-01 GE CIMPLICITY that was published October 5,...

6.8CVSS7.4AI score0.0075EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2017/10/05 12:00 a.m.13 views

The vulnerability of the GE Proficy HMI/SCADA iFIX monitoring tool for technological operations, the client-server application for data processing and control of technological operations (Proficy HMI/SCADA CIMPLICITY), and the Proficy Historian repository lies in the insufficient security of account protection, allowing attackers to obtain user passwords.

The vulnerability of the GE Proficy HMI/SCADA iFIX control system, the client-server application for data processing and control operations, as well as the Proficy HMI/SCADA CIMPLICITY control system and the Proficy Historian repository, is related to insufficiently secure account protection...

6.4CVSS6.6AI score0.00369EPSS
SaveExploits0References5Affected Software2
Rows per page
Query Builder