PT-2025-27566 · Unknown · Conprosys Hmi System

Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions prior to 3.7.7 Description: The issue concerns the exposure of a PHP phpinfo debug page to unauthenticated users, potentially containing sensitive data useful for an attacker. Recommendations: For versions...

6.9CVSS6.5AI score0.00599EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2025/07/01 12:0 a.m.8 views

Contec CONPROSYS HMI System 安全漏洞

Contec CONPROSYS HMI System is an HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product based on HTML5 technology from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.7.7, which stems from cross-site scripting ...

6.1CVSS6AI score0.01083EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/07/01 12:0 a.m.13 views

PT-2025-27565 · Unknown · Conprosys Hmi System

Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions prior to 3.7.7 Description: The issue is related to Cross-Site Scripting XSS in the getqsetting.php functionality, which could allow reflected execution of scripts in the browser on interaction...

5.1CVSS5.7AI score0.01083EPSS
SaveExploits0References3
CNVD
CNVD
added 2025/06/24 12:0 a.m.8 views

Fuji Electric Smart Editor Buffer Overflow Vulnerability

Fuji Electric Smart Editor is an editing software mainly used to configure and program HMI Human Machine Interface devices. A buffer overflow vulnerability exists in Fuji Electric Smart Editor, which is caused by an out-of-bounds write and can be exploited by an attacker to execute arbitrary code...

8.4CVSS8.3AI score0.00186EPSS
SaveExploits0References1
CNVD
CNVD
added 2025/06/24 12:0 a.m.6 views

Fuji Electric Smart Editor Buffer Overflow Vulnerability

Fuji Electric Smart Editor is an editing software mainly used to configure and program HMI Human Machine Interface devices. A buffer overflow vulnerability exists in Fuji Electric Smart Editor, which originates from an out-of-bounds read and can be exploited by an attacker to execute arbitrary co...

8.4CVSS8.1AI score0.00161EPSS
SaveExploits0References1
CNVD
CNVD
added 2025/06/11 12:0 a.m.6 views

Delta Electronics CNCSoft-G2 Buffer Overflow Vulnerability (CNVD-2025-12362)

Delta Electronics CNCSoft-G2 is a human-machine interface HMI software from Delta Electronics, China. A buffer overflow vulnerability exists in Delta Electronics CNCSoft-G2 V2.1.0.20 and earlier versions, which stems from a lack of validation of user-supplied files and can be exploited by an...

7.3CVSS8.2AI score0.00361EPSS
SaveExploits0References1
CNVD
CNVD
added 2025/05/26 12:0 a.m.4 views

Delta Electronics CNCSoft-G2 Buffer Overflow Vulnerability (CNVD-2025-12364)

Delta Electronics CNCSoft-G2 is a human-machine interface HMI software from Delta Electronics, China. The Delta Electronics CNCSoft-G2 suffers from a buffer overflow vulnerability that originates from insufficient validation of user-supplied data lengths, which can be exploited by an attacker to...

8.4CVSS7.8AI score0.00274EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2025/05/26 12:0 a.m.13 views

The vulnerability of the VS6MemInIF!set_temp_typedefault() function in the HMI configuration software for Monitouch V-SFT allows a malicious individual to gain unauthorized access to protected information, execute arbitrary code, or cause service failure.

The vulnerability of the VS6MemInIF!settemptypedefault function in the HMI configuration software for Monitouch V-SFT is related to the execution of operations outside the buffer in memory. Exploiting this vulnerability can allow an attacker to gain unauthorized access to protected information,...

7.8CVSS7.8AI score0.00211EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2025/05/26 12:0 a.m.18 views

Vulnerability of the VS6EditData!CDrawSLine::GetRectArea() function of the HMI configuration software for Monitouch V-SFT: This vulnerability allows an attacker to gain unauthorized access to protected information, execute arbitrary code, or cause a service failure.

The vulnerability of the VS6EditData!CDrawSLine::GetRectArea function of the HMI configuration software for Monitouch V-SFT is related to the occurrence of operations outside the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to gain unauthorized access to...

7.8CVSS7.7AI score0.00191EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2025/05/26 12:0 a.m.17 views

Vulnerability of the VS6EditData!CGamenDataRom::set_mr400_strc() function in the programming tool for configuring HMI interfaces of Monitouch V-SFT: This allows an attacker to gain unauthorized access to protected information, execute arbitrary code, or cause a service failure.

The vulnerability of the VS6EditData!CGamenDataRom::setmr400strc function in the HMI configuration software for Monitouch V-SFT is related to the execution of operations outside the buffer in memory. Exploiting this vulnerability could allow an attacker to gain unauthorized access to protected...

7.8CVSS7.8AI score0.00191EPSS
SaveExploits0References3Affected Software1
RedhatCVE
RedhatCVE
added 2025/05/23 6:2 a.m.9 views

CVE-2023-28657

Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...

8.8CVSS6.6AI score0.00708EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 6:1 a.m.6 views

CVE-2023-28399

Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...

7.8CVSS6.7AI score0.00182EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 6:1 a.m.6 views

CVE-2023-28827

A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...

8.2CVSS6.8AI score0.00453EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 5:52 a.m.10 views

CVE-2023-22339

Improper access control vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product...

7.5CVSS7AI score0.01137EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 5:51 a.m.6 views

CVE-2023-22373

Cross-site scripting vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information...

5.4CVSS6.4AI score0.01871EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 4:35 a.m.6 views

CVE-2023-49713

Denial-of-service DoS vulnerability exists in NetBIOS service of HMI GC-A2 series. If a remote unauthenticated attacker sends a specially crafted packets to specific ports, a denial-of-service DoS condition may occur...

7.5CVSS7AI score0.00981EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 3:38 a.m.8 views

CVE-2023-28824

Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...

4.9CVSS7AI score0.00641EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 3:37 a.m.9 views

CVE-2023-28713

Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...

8.1CVSS6.5AI score0.00431EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 3:37 a.m.11 views

CVE-2023-28651

Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...

4.8CVSS6.5AI score0.62419EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/23 3:14 a.m.9 views

CVE-2023-22331

Use of default credentials vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information...