Lucene search
K

42 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2021-23738

Malware in sbrugna...

9.8CVSS9.2AI score0.00802EPSS
Exploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2021-23734

Malware in sbrugna...

9.8CVSS9.4AI score0.02029EPSS
Exploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2021-23736

Malware in sbrugna...

9.8CVSS9.4AI score0.07565EPSS
Exploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2021-23737

Malware in sbrugna...

9.8CVSS9.4AI score0.00802EPSS
Exploits0References6
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2021-23735

Malware in sbrugna...

9.8CVSS9.4AI score0.07565EPSS
Exploits0References6
RedhatCVE
RedhatCVE
added 2025/05/22 8:54 p.m.0 views

CVE-2021-37167

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

10CVSS7.3AI score0.00584EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:54 p.m.1 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.8CVSS7.4AI score0.00575EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:54 p.m.0 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8CVSS7.6AI score0.00802EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:54 p.m.0 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.8CVSS7.3AI score0.02029EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:53 p.m.0 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8CVSS7.4AI score0.00867EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:53 p.m.2 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

9.8CVSS7.8AI score0.07565EPSS
Exploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.23 views

HMI3 Control Panel Trust Management Issue Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...

7.5CVSS2.1AI score0.00575EPSS
Exploits0Affected Software1
OSV
OSV
added 2021/08/02 1:15 p.m.0 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8CVSS7.8AI score0.00802EPSS
Exploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.14 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8CVSS0.00802EPSS
Exploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.0 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.8CVSS7.3AI score0.02029EPSS
Exploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.19 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.8CVSS0.02029EPSS
Exploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.20 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.8CVSS0.00575EPSS
Exploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.18 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

9.8CVSS0.07565EPSS
Exploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.17 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

9.8CVSS0.07565EPSS
Exploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.0 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

9.8CVSS7.8AI score0.07565EPSS
Exploits0References4
Rows per page
Query Builder