Lucene search
+L

128 matches found

CNVD
CNVD
added 2020/05/15 12:0 a.m.4 views

Advantech WebAccessNode suffers from an arbitrary path file deletion vulnerability (CNVD-2020-30159)

Advantech WebAccessNode is a fully Internet Explorer-based HMI/SCADA monitoring software. Advantech WebAccessNode has an arbitrary path file deletion vulnerability that can be exploited by an attacker to delete arbitrary path files on the system...

7AI score
SaveExploits0
NVD
NVD
added 2020/04/15 5:15 p.m.18 views

CVE-2020-6992

A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...

6.7CVSS6.7AI score0.00392EPSS
SaveExploits0References1
Prion
Prion
added 2020/04/15 5:15 p.m.19 views

Privilege escalation

A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...

4.6CVSS6.7AI score0.00392EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/04/15 4:39 p.m.22 views

CVE-2020-6992

A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...

6.7AI score0.00392EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/03/27 12:0 a.m.5 views

Advantech WebAccess Buffer Overflow Vulnerability (CNVD-2020-19926)

Advantech WebAccess is a set of HMI/SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphic display and real-time data control, and provides remote control and management of automation equipment. A buffer overflow vulnerability exists in...

8.8CVSS7.5AI score0.02123EPSS
SaveExploits0References1
zdt
zdt
added 2019/11/18 12:0 a.m.84 views

Open Proficy HMI-SCADA 5.0.0.25920 - (Password) Denial of Service Exploit

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Version: 5.0.0.25920 Vulnerabilit...

7.4AI score
SaveExploits0
Packet Storm
Packet Storm
added 2019/11/18 12:0 a.m.137 views

Open Proficy HMI-SCADA 5.0.0.25920 Denial Of Service

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Versio...

7.4AI score
SaveExploits0
exploitpack
exploitpack
added 2019/11/18 12:0 a.m.48 views

Open Proficy HMI-SCADA 5.0.0.25920 - Password Denial of Service (PoC)

Open Proficy HMI-SCADA 5.0.0.25920 - Password Denial of Service PoC Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: Ap...

7.3AI score
SaveExploits0
Exploit DB
Exploit DB
added 2019/11/18 12:0 a.m.156 views

Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service (PoC)

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Versio...

5.3AI score
SaveExploits0
Prion
Prion
added 2018/12/24 4:29 p.m.13 views

Design/Logic Flaw

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

4.6CVSS8.4AI score0.00322EPSS
SaveExploits0References1Affected Software4
NVD
NVD
added 2018/12/24 4:29 p.m.17 views

CVE-2018-7793

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

8.7CVSS8.6AI score0.00322EPSS
SaveExploits0References1
CVE
CVE
added 2018/12/24 4:0 p.m.47 views

CVE-2018-7793

A credential management vulnerability exists in FoxView HMI SCADA across Foxboro DCS, Foxboro Evo, and IA Series. Affects versions prior to CCS 9.4 (DCS Core Services) and FoxView 10.5. The issue could allow unauthorized disclosure, modification, or disruption in service when the password is modi...

8.7CVSS8.4AI score0.00322EPSS
SaveExploits0References1Affected Software4
Cvelist
Cvelist
added 2018/12/24 4:0 p.m.19 views

CVE-2018-7793

A Credential Management vulnerability exists in FoxView HMI SCADA All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 CCS 9.4 and FoxView 10.5. which could cause unauthorized disclosure, modification, or disruption in service when the password is...

8.6AI score0.00322EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2017/10/05 12:0 a.m.9 views

The vulnerability of the GE Proficy HMI/SCADA iFIX monitoring tool for technological operations, the client-server application for data processing and control of technological operations (Proficy HMI/SCADA CIMPLICITY), and the Proficy Historian repository lies in the insufficient security of account protection, allowing attackers to obtain user passwords.

The vulnerability of the GE Proficy HMI/SCADA iFIX control system, the client-server application for data processing and control operations, as well as the Proficy HMI/SCADA CIMPLICITY control system and the Proficy Historian repository, is related to insufficiently secure account protection...

6.4CVSS6.6AI score0.00369EPSS
SaveExploits0References5Affected Software2
ICS
ICS
added 2017/10/05 12:0 a.m.42 views

GE CIMPLICITY (Update A)

CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow UPDATED INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-278-01 GE CIMPLICITY that was published October 5,...

6.8CVSS7.4AI score0.0075EPSS
SaveExploits0References2
ICS
ICS
added 2017/10/05 12:0 a.m.41 views

GE CIMPLICITY

CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: CIMPLICITY Vulnerability: Stack-based Buffer Overflow AFFECTED PRODUCTS The following versions of CIMPLICITY, an HMI/SCADA management platform, are affected: CIMPLICITY Versions 9.0 and prior. IMPACT...

6.8CVSS1AI score0.0075EPSS
SaveExploits0References27
ICS
ICS
added 2017/06/13 12:0 a.m.58 views

Trihedral Engineering Limited VTScada

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Trihedral Engineering Limited Equipment: VTScada Vulnerability: Resource Consumption, Cross-Site Scripting, Information Exposure AFFECTED PRODUCTS The following versions of VTScada, an HMI SCADA software, are affected...

7.8CVSS7.7AI score0.01689EPSS
SaveExploits0References3
Prion
Prion
added 2017/02/13 9:59 p.m.17 views

Session fixation

An issue was discovered in General Electric GE Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has acces...

4.4CVSS6.8AI score0.00369EPSS
SaveExploits0References3Affected Software3
Cvelist
Cvelist
added 2017/02/13 9:0 p.m.29 views

CVE-2016-9360

An issue was discovered in General Electric GE Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has acces...

6.3AI score0.00369EPSS
SaveExploits0References3
ICS
ICS
added 2017/01/17 12:0 a.m.87 views

GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian Vulnerability (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-336-05 GE Proficy HMI/SCADA IFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian Vulnerability that was published January 17, 2017, on the NCCIC/ICS-CERT web site. GE has reported an insufficiently protecte...

6.7CVSS1.1AI score0.00369EPSS
SaveExploits0References27
Rows per page
Query Builder