Lucene search
+L

98 matches found

Kitploit
Kitploit
•added 2026/10/13 12:26 p.m.•21 views

CVE-2026-11499

🚨 CVE-2026-11499 Stack-Based Buffer Overflow in Tenda HG7 / HG9 / HG10 Routers 📖 Overview CVE-2026-11499 is a reported stack-based buffer overflow vulnerability affecting several Tenda router models , including: HG7 HG9 HG10 Successful exploitation may allow an attacker to trigger a crash, denial...

10CVSS8.8AI score0.06635EPSS
SaveExploits3
Kitploit
Kitploit
•added 2026/10/08 6:10 p.m.•20 views

tenda-hg10-rce

CVE-2026-1689 Summary A command injection vulnerability exists in the Tenda HG10 router. It occurs in the formLogin endpoint due to improper handling of the Host parameter. No authentication credentials are verified as this executes before the check. User input from the Host header is directly...

7.5CVSS7.7AI score0.03128EPSS
SaveExploits1
NVD
NVD
•added 2026/10/02 1:17 p.m.•17 views

CVE-2026-104610

A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138enxpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed...

10CVSS0.00644EPSS
SaveExploits0References6
CVE
CVE
•added 2026/10/02 12:00 p.m.•23 views

CVE-2026-104610

A stack-based buffer overflow vulnerability exists in the Boa Web Server component of Tenda HG7, HG9, and HG10 (300001138_en_xpon) devices. The issue is triggered by manipulating the Ethtype argument within the boaGetVar function of the /boaform/formLoopBack file. This vulnerability can be exploi...

10CVSS8.7AI score0.00644EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2026/10/02 12:00 p.m.•55 views

CVE-2026-104610 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow

A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138enxpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed...

10CVSS0.00644EPSS
SaveExploits0References6
EUVD
EUVD
•added 2026/10/02 12:00 p.m.•16 views

EUVD-2026-91570

A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138enxpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed...

10CVSS8.7AI score0.00644EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
•added 2026/10/02 12:00 p.m.•17 views

CVE-2026-104610 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow

A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138enxpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed...

10CVSS8.7AI score0.00644EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/10/02 12:00 a.m.•7 views

CVE-2026-104610: Stack-based Buffer Overflow

A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138enxpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed...

10CVSS8.7AI score0.00644EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/10/02 12:00 a.m.•14 views

PT-2026-104299

Name of the Vulnerable Software and Affected Versions Tenda HG7 affected versions not specified Tenda HG9 affected versions not specified Tenda HG10 300001138 en xpon affected versions not specified Description A stack-based buffer overflow occurs in the Boa Web Server component due to improper...

10CVSS8.4AI score0.00644EPSS
SaveExploits0References15
NVD
NVD
•added 2026/09/06 5:16 a.m.•15 views

CVE-2026-86167

A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgponloid leads to os command injection. Remote exploitation of the attack is possible. The exploit is...

9.9CVSS0.0273EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
•added 2026/09/06 4:30 a.m.•13 views

CVE-2026-86167 Tenda HG10 Boa formgponConf os command injection

A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgponloid leads to os command injection. Remote exploitation of the attack is possible. The exploit is...

9.9CVSS8.2AI score0.0273EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2026/09/06 4:30 a.m.•42 views

CVE-2026-86167 Tenda HG10 Boa formgponConf os command injection

A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgponloid leads to os command injection. Remote exploitation of the attack is possible. The exploit is...

9.9CVSS0.0273EPSS
SaveExploits0References6
EUVD
EUVD
•added 2026/09/06 4:30 a.m.•9 views

EUVD-2026-72055

A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgponloid leads to os command injection. Remote exploitation of the attack is possible. The exploit is...

9.9CVSS8AI score0.0273EPSS
SaveExploits0References6
CVE
CVE
•added 2026/09/06 4:30 a.m.•46 views

CVE-2026-86167

Tenda HG10 (firmware 300001138) is affected by an OS command injection vulnerability in the Boa component. The vulnerable function formgponConf , located at /boaform/admin/formgponConf, allows an attacker to manipulate the fmgpon_loid argument to inject and execute arbitrary OS commands. The vuln...

9.9CVSS8.2AI score0.0273EPSS
SaveExploits0References6
NVD
NVD
•added 2026/09/06 4:18 a.m.•12 views

CVE-2026-86165

A vulnerability was found in Tenda HG10 300001138. This vulnerability affects the function formURL of the file /boaform/admin/formURL. Performing a manipulation of the argument Keywd/urlFQDN results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and cou...

10CVSS0.01132EPSS
SaveExploits0References7
NVD
NVD
•added 2026/09/06 4:18 a.m.•12 views

CVE-2026-86166

A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit h...

9CVSS0.00854EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2026/09/06 4:00 a.m.•56 views

CVE-2026-86166 Tenda HG10 Boa Web Server formWanRedirect buffer overflow

A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit h...

9CVSS0.00854EPSS
SaveExploits0References6
EUVD
EUVD
•added 2026/09/06 4:00 a.m.•17 views

EUVD-2026-72050

A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit h...

9CVSS8.2AI score0.00854EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
•added 2026/09/06 4:00 a.m.•13 views

CVE-2026-86166 Tenda HG10 Boa Web Server formWanRedirect buffer overflow

A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formWanRedirect of the file /boaform/formWanRedirect of the component Boa Web Server. Executing a manipulation of the argument if can lead to buffer overflow. The attack may be launched remotely. The exploit h...

9CVSS8.2AI score0.00854EPSS
SaveExploits0References6
CVE
CVE
•added 2026/09/06 4:00 a.m.•39 views

CVE-2026-86166

Tenda HG10 (firmware 300001138 ) is affected by a buffer overflow in the Boa Web Server component, specifically in the formWanRedirect() function of the /boaform/formWanRedirect endpoint. A remote, low-privilege attacker can trigger the vulnerability by manipulating the if argument, leading to hi...

9CVSS8.2AI score0.00854EPSS
SaveExploits0References6
Rows per page
Query Builder