2651 matches found
CVE-2021-27113
An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters...
Stack overflow
An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. Within the handler function of the /goform/addassignment route, a very long text entry for the"'sip" and "smac" fields could lead to a Stack-Based Buffer Overflow and overwrite the return address...
VulnCheck KEV: CVE-2018-14558
Tenda AC7, AC9, and AC10 devices contain a command injection vulnerability due to the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Successful exploitation allows an attacker to execute OS commands via a crafted goform/setUsbUnload request...
CVE-2021-3304
Sagemcom F@ST 3686 v2 3.495 devices have a buffer overflow via a long sessionKey to the goform/login URI...
CVE-2021-3304
Sagemcom F@ST 3686 v2 3.495 devices have a buffer overflow via a long sessionKey to the goform/login URI...
Sagemcom F@ST3686 Buffer Error Vulnerability
The Sagemcom F@ST3686 is a router from Sagemcom France. A buffer error vulnerability exists in the Sagemcom F@ST 3686 v2 3.495 devices, which originates from a long sessionKey to a goform login URI...
Belkin LINKSYS RE6500 Remote Code Execution Vulnerability
The Linksys RE6500 is an AC1200 dual-band WiFi extender from Belkin. A remote code execution vulnerability exists in Belkin LINKSYS RE6500 versions prior to 1.0.012.001. A remote attacker can exploit the vulnerability by using shell metacharacters on the goform/setSysAdm page to execute arbitrary...
CVE-2020-35713
Belkin LINKSYS RE6500 devices before 1.0.012.001 allow remote attackers to execute arbitrary commands or set a new password via shell metacharacters to the goform/setSysAdm page...
CVE-2020-35713
Belkin LINKSYS RE6500 devices before 1.0.012.001 allow remote attackers to execute arbitrary commands or set a new password via shell metacharacters to the goform/setSysAdm page...
CVE-2020-35714
Belkin LINKSYS RE6500 devices before 1.0.11.001 allow remote authenticated users to execute arbitrary commands via goform/systemCommand?command= in conjunction with the goform/pingstart program...
Belkin LINKSYS RE6500 操作系统命令注入漏洞
The Linksys RE6500 is an AC1200 dual-band WiFi extender from Belkin. A remote code execution vulnerability exists in Belkin LINKSYS RE6500 versions prior to 1.0.012.001. A remote attacker can exploit the vulnerability by using shell metacharacters on the goform/setSysAdm page to execute arbitrary...
Belkin LINKSYS RE6500 Command Injection Vulnerability
The Belkin LINKSYS RE6500 is a wireless router from Belkin USA. A command injection vulnerability exists in Belkin LINKSYS RE6500 devices prior to version 1.0.11.001, which can be exploited to allow a remote authenticated user to execute arbitrary commands via goform system commands...
Tenda AC15 Remote Code Execution Vulnerability
Tenda AC15 AC1900 is a wireless router from Tenda, a Chinese company. A security vulnerability exists in the goform/AdvSetLanip endpoint in the Tenda AC15 AC1900 version 15.03.05.19. The vulnerability can be exploited by a remote attacker to execute arbitrary system commands via shell...
Tenda AC15 AC1900 Remote Code Execution Vulnerability
Tenda AC15 AC1900 is a wireless router from Tenda, a Chinese company. A remote code execution vulnerability exists in the goform/setUsbUnload endpoint in the Tenda AC15 AC1900 version 15.03.05.19, which can be exploited to execute arbitrary system commands via the deviceName POST parameter...
CVE-2020-10987
The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter...
Buffer overflow vulnerability in multiple Tenda products (CNVD-2020-31408)
The Tenda AC9, among others, is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in httpd in several Tenda products. The vulnerability can be exploited to execute arbitrary code by sending the 'deviceId' and 'time' parameters to the...
Buffer overflow vulnerability in multiple Tenda products (CNVD-2020-31387)
The Tenda AC9, among others, is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in httpd in multiple Tenda products. The vulnerability can be exploited to execute arbitrary code by sending the 'entrys' and 'mitInterface' parameters to the /goform/addressNa...
Buffer overflow vulnerability in multiple Tenda products (CNVD-2020-31386)
The Tenda AC9, among others, is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in httpd in multiple Tenda products. The vulnerability can be exploited to execute arbitrary code by sending the 'schedStartTime' and 'schedEndTime' parameters to the...
CVE-2019-13395
The Voo branded NETGEAR CG3700b custom firmware V2.02.03 allows CSRF against all /goform/ URIs. An attacker can modify all settings including WEP/WPA/WPA2 keys, restore the router to factory settings, or even upload an entire malicious configuration file...