Lucene search
+L

2651 matches found

CVE
CVE
added 2022/09/23 2:17 p.m.58 views

CVE-2022-40854

CVE-2022-40854 affects the Tenda AC18 router (firmware V15.03.05.19) due to a stack overflow in the /goform/fast_setting_wifi_set handler. The root cause is a missing size check on incoming data, enabling an attacker to potentially achieve remote code execution or denial of service. The entry lis...

9.8CVSS9.5AI score0.01013EPSS
SaveExploits1References1Affected Software1
OSV
OSV
added 2022/09/23 2:15 p.m.7 views

CVE-2022-40862

Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting...

9.8CVSS5.8AI score0.0122EPSS
SaveExploits1References2
Prion
Prion
added 2022/09/23 2:15 p.m.18 views

Stack overflow

Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand-FUN0007dd20 with request /goform/SetNetControlList...

7.5CVSS9.4AI score0.01013EPSS
SaveExploits1References1Affected Software1
Prion
Prion
added 2022/09/23 2:15 p.m.22 views

Stack overflow

Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting...

7.5CVSS9.5AI score0.0122EPSS
SaveExploits1References2Affected Software2
CVE
CVE
added 2022/09/23 1:59 p.m.53 views

CVE-2022-40853

The CVE-2022-40853 entry maps to a stack overflow in Tenda AC15 router (V15.03.05.19) caused by the list parameter in /goform/fast_setting_wifi_set, with the input data lacking proper size checks. This vulnerability has a high-impact profile (remote code execution or denial of service) and is exp...

9.8CVSS9.6AI score0.01013EPSS
SaveExploits1References1Affected Software1
OSV
OSV
added 2022/09/15 8:15 p.m.8 views

CVE-2022-38325

Tenda AC15 WiFi Router V15.03.05.19multi and AC18 WiFi Router V15.03.05.19multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile...

9.8CVSS6.2AI score0.00973EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
added 2022/09/15 12:0 a.m.10 views

PT-2022-24368 · Tenda · Tenda Ac18 Wifi Router +1

Name of the Vulnerable Software and Affected Versions: Tenda AC15 WiFi Router version V15.03.05.19 multi Tenda AC18 WiFi Router version V15.03.05.19 multi Description: A buffer overflow issue was discovered via the filePath parameter at the "/goform/expandDlnaFile" API endpoint. Recommendations:...

9.8CVSS9.5AI score0.00973EPSS
SaveExploits1References4
ATTACKERKB
ATTACKERKB
added 2022/09/07 7:15 p.m.13 views

CVE-2022-38313

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo...

9.8CVSS5.9AI score0.00973EPSS
SaveExploits1References2
OSV
OSV
added 2022/09/07 7:15 p.m.7 views

CVE-2022-38309

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg...

9.8CVSS5.9AI score0.00973EPSS
SaveExploits1References1
NVD
NVD
added 2022/09/07 7:15 p.m.27 views

CVE-2022-38313

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo...

9.8CVSS0.00973EPSS
SaveExploits1References1
OSV
OSV
added 2022/09/07 7:15 p.m.8 views

CVE-2022-38314

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo...

9.8CVSS5.9AI score0.00973EPSS
SaveExploits1References1
OSV
OSV
added 2022/09/07 7:15 p.m.7 views

CVE-2022-38310

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg...

9.8CVSS5.9AI score0.00973EPSS
SaveExploits1References1
Cvelist
Cvelist
added 2022/09/07 6:41 p.m.31 views

CVE-2022-38312

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind...

9.9AI score0.00973EPSS
SaveExploits1References1
Cvelist
Cvelist
added 2022/09/07 6:41 p.m.42 views

CVE-2022-38311

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet...

9.9AI score0.00973EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2022/09/07 12:0 a.m.7 views

Tenda AC18 缓冲区错误漏洞

The Tenda AC18 is a router from the Chinese company Tenda. A security vulnerability exists in the Tenda AC18 Router version v15.03.05.19 and v15.03.05.05, which originates from a discovery containing a stack overflow via the list parameter of /goform/SetVirtualServerCfg...

9.8CVSS8.4AI score0.00973EPSS
SaveExploits1References2
ATTACKERKB
ATTACKERKB
added 2022/08/31 11:15 p.m.4 views

CVE-2022-37123

D-link DIR-816 A2v1.10CNB04.img is vulnerable to Command injection via /goform/form2userconfig.cgi...

8.8CVSS7.4AI score0.02745EPSS
SaveExploits1References3
OSV
OSV
added 2022/08/31 11:15 p.m.6 views

CVE-2022-37129

D-Link DIR-816 A2v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte4836B0 by snprintf, and finally doSystem&byte4836B0; will be executed, resulting in a command injection...

8.8CVSS7.3AI score0.08454EPSS
SaveExploits1References2
ATTACKERKB
ATTACKERKB
added 2022/08/31 11:15 p.m.12 views

CVE-2022-37129

D-Link DIR-816 A2v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte4836B0 by snprintf, and finally doSystem&byte4836B0; will be executed, resulting in a command injection...

8.8CVSS7.3AI score0.08454EPSS
SaveExploits1References3
OSV
OSV
added 2022/08/31 11:15 p.m.9 views

CVE-2022-37130

In D-Link DIR-816 A2v1.10CNB04, DIR-878 DIR878FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability...

9.8CVSS5.8AI score0.26335EPSS
SaveExploits1References3
Prion
Prion
added 2022/08/31 11:15 p.m.21 views

Command injection

In D-Link DIR-816 A2v1.10CNB04, DIR-878 DIR878FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability...

7.5CVSS9.6AI score0.26335EPSS
SaveExploits1References3Affected Software1
Rows per page
Query Builder