Lucene search
+L

3704 matches found

RedhatCVE
RedhatCVE
•added 2025/08/25 12:27 p.m.•16 views

CVE-2025-9361

A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The affected element is the function ipRangeBlockManageRule of the file /goform/ipRangeBlockManageRule. Performing manipulation of the argument...

9CVSS7.3AI score0.00966EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/08/25 11:14 a.m.•19 views

CVE-2025-9360

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Impacted is the function accessControlAdd of the file /goform/accessControlAdd. Such manipulation of the argument ruleName/schedule lead...

9CVSS7.4AI score0.01244EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/08/25 9:38 a.m.•19 views

CVE-2025-9359

A weakness has been identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RPcheckCredentialsByBBS of the file /goform/RPcheckCredentialsByBBS. This manipulation of the argument ssidhex/pwd...

9CVSS7.2AI score0.01EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/08/25 8:12 a.m.•17 views

CVE-2025-9358

A security flaw has been discovered in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setSysAdm of the file /goform/setSysAdm. The manipulation of the argument admpasshint results in...

9CVSS7.3AI score0.01EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
•added 2025/08/25 12:00 a.m.•24 views

PT-2025-35536

Name of the Vulnerable Software and Affected Versions Tenda CH22 version 1.0.0.1 Description A buffer overflow issue exists in the formexeCommand function of the /goform/exeCommand file. Manipulation of the cmdinput argument can lead to a buffer overflow, potentially allowing for remote...

9CVSS8.9AI score0.00661EPSS
SaveExploits0References16
BDU FSTEC
BDU FSTEC
•added 2025/08/25 12:00 a.m.•17 views

The vulnerability of the fromGstDhcpSetSer() function in the /goform/GstDhcpSetSer file of the Tenda FH1202 router software allows a attacker to execute arbitrary code.

The vulnerability of the fromGstDhcpSetSer function in the /goform/GstDhcpSetSer file of the Tenda FH1202 router’s software is related to the execution of operations outside the buffer in memory. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code...

9CVSS7.9AI score0.00891EPSS
SaveExploits1References2
BDU FSTEC
BDU FSTEC
•added 2025/08/25 12:00 a.m.•16 views

The vulnerability of the `save_virtualser_data` function in the `/goform/formSetVirtualSer` file of the Tenda AC20 router’s microprogramming system allows a attacker to execute arbitrary code or cause a service failure.

The vulnerability of the savevirtualserdata function in the /goform/formSetVirtualSer file of the Tenda AC20 router’s microprogramming system is related to reading data beyond the buffer boundaries in memory when processing the list parameter. Exploiting this vulnerability allows an attacker to...

9CVSS7.8AI score0.00875EPSS
SaveExploits1References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/08/25 12:00 a.m.•16 views

The vulnerability of the fromVirtualSer (/goform/VirtualSert) function in the Tenda FH1202 router software allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the fromVirtualSer /goform/VirtualSert function in the Tenda FH1202 router microprogramming system is related to reading data beyond the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to compromise the confidentiality, integrity, and...

9CVSS7.5AI score0.01013EPSS
SaveExploits1References2
RedhatCVE
RedhatCVE
•added 2025/08/24 9:12 p.m.•19 views

CVE-2025-9355

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function scheduleAdd of the file /goform/scheduleAdd. Performing manipulation of the argument ruleName results in...

9CVSS7.2AI score0.00966EPSS
SaveExploits1References1
NVD
NVD
•added 2025/08/24 4:15 p.m.•18 views

CVE-2025-9393

A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaProfile of the file /goform/addStaProfile. Performing manipulation of the argument...

9CVSS0.01002EPSS
SaveExploits1References6
Cvelist
Cvelist
•added 2025/08/24 3:32 p.m.•29 views

CVE-2025-9393 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaProfile stack-based overflow

A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaProfile of the file /goform/addStaProfile. Performing manipulation of the argument...

9CVSS0.01002EPSS
SaveExploits1References6
OSV
OSV
•added 2025/08/24 3:15 p.m.•15 views

CVE-2025-9392

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function qosClassifier of the file /goform/qosClassifier. Such manipulation of the argument...

8.7CVSS6.5AI score0.04699EPSS
SaveExploits1References6
NVD
NVD
•added 2025/08/24 3:15 p.m.•13 views

CVE-2025-9392

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function qosClassifier of the file /goform/qosClassifier. Such manipulation of the argument...

9CVSS0.04699EPSS
SaveExploits1References6
CVE
CVE
•added 2025/08/24 3:02 p.m.•49 views

CVE-2025-9392

The CVE-2025-9392 entry concerns Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 devices. The vulnerability is in the qosClassifier function of /goform/qosClassifier, where improper manipulation of dir, sFromPort, sToPort, dFromPort, dToPort, protocol, layer7, dscp, and remark_dscp arguments le...

9CVSS8.2AI score0.04699EPSS
SaveExploits1References6Affected Software1
Cvelist
Cvelist
•added 2025/08/24 3:02 p.m.•29 views

CVE-2025-9392 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 qosClassifier stack-based overflow

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function qosClassifier of the file /goform/qosClassifier. Such manipulation of the argument...

9CVSS0.04699EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
•added 2025/08/24 12:00 a.m.•23 views

PT-2025-34569 · Linksys · Linksys Re6250 +5

Name of the Vulnerable Software and Affected Versions: Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 versions 1.0.013.001 through 1.0.04.002 and 1.1.05.003 and 1.2.07.001 Description: A stack-based buffer overflow vulnerability exists in the addStaProfile function within the...

9CVSS8.9AI score0.01002EPSS
SaveExploits1References13
Positive Technologies
Positive Technologies
•added 2025/08/24 12:00 a.m.•18 views

PT-2025-34568 · Linksys · Linksys Re6250 +5

Name of the Vulnerable Software and Affected Versions: Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 versions 1.0.013.001 through 1.2.07.001 Description: A security vulnerability exists in the Linksys RE series of range extenders. Manipulation of the dir, sFromPort, sToPort, dFromPort...

9CVSS8.9AI score0.04699EPSS
SaveExploits1References15
NVD
NVD
•added 2025/08/23 2:15 p.m.•23 views

CVE-2025-9362

A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument...

8.8CVSS0.00571EPSS
SaveExploits1References5
RedhatCVE
RedhatCVE
•added 2025/08/23 1:35 p.m.•20 views

CVE-2025-9298

A flaw has been found in Tenda M3 1.0.0.12. Affected is the function formQuickIndex of the file /goform/QuickIndex. Executing manipulation of the argument PPPOEPassword can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used...

9.8CVSS8.8AI score0.01109EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/08/23 1:32 p.m.•35 views

CVE-2025-9362 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 urlFilterManageRule stack-based overflow

A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument...

6.5CVSS0.00571EPSS
SaveExploits1References5
Rows per page
Query Builder