3681 matches found
EUVD-2017-5770
Malware in sbrugna...
EUVD-2016-1498
Malware in sbrugna...
PT-2025-40978
Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.05.18 Description A stack-based buffer overflow exists in Tenda AC15 routers. The issue is due to the manipulation of the Password argument within the file '/goform/fast setting pppoe set'. This can be exploited...
CVE-2025-11356: Buffer Copy without Checking Size of Input
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and coul...
CVE-2025-11355: Buffer Copy without Checking Size of Input
A vulnerability has been found in UTT 1250GW up to v2v3.2.2-200710. Affected by this vulnerability is the function strcpy of the file /goform/aspChangeChannel. The manipulation of the argument pvid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been...
Tenda AC20 安全漏洞
Tenda AC20 is a home router from Tenda. The Tenda AC20 suffers from a buffer overflow vulnerability, which originates from the incorrect operation of the sscanf function parameter timeZone in the file /goform/fastsettingwifiset, for which no detailed vulnerability details are available at this ti...
CVE-2025-11388: Stack-based Buffer Overflow
A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used...
CVE-2025-11389: Stack-based Buffer Overflow
A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing a manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to...
PT-2025-40976
Name of the Vulnerable Software and Affected Versions Tenda AC20 versions up to 16.03.08.12 Description A flaw exists in Tenda AC20 that allows remote attackers to trigger a buffer overflow. The issue is located in the sscanf function within the /goform/fast setting wifi set file. The timeZone...
CVE-2025-11303
A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted...
CVE-2025-11325
A security flaw has been discovered in Tenda AC18 15.03.05.196318. Affected by this issue is some unknown functionality of the file /goform/fastsettingpppoeset. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out...
CVE-2025-11324
CVE-2025-11324 affects Tenda AC18 (firmware 15.03.05.19(6318)). The vulnerability is a stack-based buffer overflow in an unknown function within /goform/setNotUpgrade caused by improper handling of the newVersion parameter. Exploitation can be performed remotely; a public exploit exists. Affected...
Tenda AC18 安全漏洞
Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 has a stack buffer overflow vulnerability, which originates from the parameter ddnsEn in the file /goform/SetDDNSCfg fails to correctly...
CVE-2025-11328: Stack-based Buffer Overflow
A vulnerability was detected in Tenda AC18 15.03.05.196318. This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be...
CVE-2025-11323: Buffer Copy without Checking Size of Input
A vulnerability was determined in UTT 1250GW up to v2v3.2.2-200710. Affected is the function strcpy of the file /goform/formUserStatusRemark. This manipulation of the argument Username causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed a...
CVE-2025-11324: Stack-based Buffer Overflow
A vulnerability was identified in Tenda AC18 15.03.05.196318. Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is public...
The vulnerability of the /goform/delete_offline_device file in D-Link DIR-823X router microprogramming software allows a perpetrator to execute arbitrary commands.
The vulnerability of the /goform/deleteofflinedevice function in the microprogramming software for D-Link DIR-823X routers is related to the lack of measures taken at the control level when processing the delvalue parameter. Exploiting this vulnerability allows an attacker to execute arbitrary...
CVE-2025-11303
A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted...
CVE-2025-11303
A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted...
CVE-2025-11303 Belkin F9K1015 mp command injection
A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted...