CVE-2025-9528

A vulnerability was determined in Linksys E1700 1.0.0.4.003. This vulnerability affects the function systemCommand of the file /goform/systemCommand. Executing manipulation of the argument command can lead to os command injection. The attack may be launched remotely. The exploit has been publicly...

5.8CVSS5AI score0.54469EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/08/29 2:02 a.m.•27 views

CVE-2025-9605 Tenda AC21/AC23 GetParentControlInfo stack-based overflow

A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has...

10CVSS0.05566EPSS
SaveExploits1References7
Vulnrichment
Vulnrichment
•added 2025/08/27 1:02 p.m.•7 views

CVE-2025-9527 Linksys E1700 QoSSetup stack-based overflow

A vulnerability was found in Linksys E1700 1.0.0.4.003. This affects the function QoSSetup of the file /goform/QoSSetup. Performing manipulation of the argument ackpolicy results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be...

9CVSS7.2AI score0.01468EPSS
SaveExploits1References6
CVE
CVE
•added 2025/08/26 2:02 p.m.•48 views

CVE-2025-9483

Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 (firmware up to 1.2.07.001) are affected by a stack-based buffer overflow in the singlePortForwardAdd function at /goform/singlePortForwardAdd. This allows remote code execution with root access by manipulating ruleName/schedule/inboundFilter. An ...

9CVSS8.2AI score0.01EPSS
SaveExploits1References6Affected Software1
CVE
CVE
•added 2025/08/26 1:32 p.m.•45 views

CVE-2025-9481

The CVE-2025-9481 entry concerns Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 devices. Affected component: the function setIpv6 in /goform/setIpv6. Root cause: manipulation of the tunrd_Prefix argument leads to a stack-based buffer overflow. Impact: remote exploitation is possible (high impa...

9CVSS8.1AI score0.01391EPSS
SaveExploits1References6Affected Software1
RedhatCVE
RedhatCVE
•added 2025/08/25 12:27 p.m.•16 views

CVE-2025-9361

A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The affected element is the function ipRangeBlockManageRule of the file /goform/ipRangeBlockManageRule. Performing manipulation of the argument...

9CVSS7.3AI score0.00966EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
•added 2025/08/25 11:14 a.m.•20 views

CVE-2025-9360

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Impacted is the function accessControlAdd of the file /goform/accessControlAdd. Such manipulation of the argument ruleName/schedule lead...

9CVSS7.4AI score0.01244EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
•added 2025/08/25 12:00 a.m.•24 views

PT-2025-35536

Name of the Vulnerable Software and Affected Versions Tenda CH22 version 1.0.0.1 Description A buffer overflow issue exists in the formexeCommand function of the /goform/exeCommand file. Manipulation of the cmdinput argument can lead to a buffer overflow, potentially allowing for remote...

9CVSS8.9AI score0.00661EPSS
SaveExploits0References16
NVD
NVD
•added 2025/08/24 4:15 p.m.•18 views

CVE-2025-9393

A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaProfile of the file /goform/addStaProfile. Performing manipulation of the argument...

9CVSS0.01002EPSS
SaveExploits1References6
CVE
CVE
•added 2025/08/24 3:02 p.m.•49 views

CVE-2025-9392

The CVE-2025-9392 entry concerns Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 devices. The vulnerability is in the qosClassifier function of /goform/qosClassifier, where improper manipulation of dir, sFromPort, sToPort, dFromPort, dToPort, protocol, layer7, dscp, and remark_dscp arguments le...

9CVSS8.2AI score0.04699EPSS
SaveExploits1References6Affected Software1
Positive Technologies
Positive Technologies
•added 2025/08/24 12:00 a.m.•18 views

PT-2025-34568 · Linksys · Linksys Re6250 +5

Name of the Vulnerable Software and Affected Versions: Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 versions 1.0.013.001 through 1.2.07.001 Description: A security vulnerability exists in the Linksys RE series of range extenders. Manipulation of the dir, sFromPort, sToPort, dFromPort...

9CVSS8.9AI score0.04699EPSS
SaveExploits1References15
CVE
CVE
•added 2025/08/23 1:32 p.m.•45 views

CVE-2025-9362

CVE-2025-9362 affects Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 (versions listed in PT-2025-34529). A stack-based overflow exists in urlFilterManageRule (/goform/urlFilterManageRule): manipulating urlFilterRuleName, scheduleUrl, or addURLFilter can trigger the overflow. The vulnerability ...

8.8CVSS7.3AI score0.00571EPSS
SaveExploits1References5Affected Software1
Cvelist
Cvelist
•added 2025/08/23 1:32 p.m.•35 views

CVE-2025-9362 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 urlFilterManageRule stack-based overflow

A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function urlFilterManageRule of the file /goform/urlFilterManageRule. Executing manipulation of the argument...

6.5CVSS0.00571EPSS
SaveExploits1References5
CVE
CVE
•added 2025/08/23 9:32 a.m.•50 views

CVE-2025-9359

The CVE-2025-9359 entry describes a stack-based buffer overflow in Linksys RP_checkCredentialsByBBS (file path /goform/RP_checkCredentialsByBBS) triggered by manipulating the ssidhex/pwd arguments. Affected devices are Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 with firmware versions 1.0.0...

9CVSS8.2AI score0.01EPSS
SaveExploits1References6Affected Software1
OSV
OSV
•added 2025/08/23 8:15 a.m.•16 views

CVE-2025-9358

A security flaw has been discovered in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setSysAdm of the file /goform/setSysAdm. The manipulation of the argument admpasshint results in...

8.7CVSS6.4AI score0.01EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
•added 2025/08/23 12:00 a.m.•20 views

PT-2025-34529 · Linksys · Linksys Re9000 +5

Name of the Vulnerable Software and Affected Versions: Linksys RE6250 version 1.0.013.001 Linksys RE6250 version 1.0.04.001 Linksys RE6250 version 1.0.04.002 Linksys RE6250 version 1.1.05.003 Linksys RE6250 version 1.2.07.001 Linksys RE6300 version 1.0.013.001 Linksys RE6300 version 1.0.04.001...

6.5CVSS6.5AI score0.00571EPSS
SaveExploits1References9
RedhatCVE
RedhatCVE
•added 2025/08/22 9:33 p.m.•17 views

CVE-2025-9248

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function RPpingGatewayByBBS of the file /goform/RPpingGatewayByBBS. The manipulation of the argument ssidhex results in...

9CVSS7.4AI score0.00962EPSS
SaveExploits1References1
OSV
OSV
•added 2025/08/20 10:15 p.m.•13 views

CVE-2025-9250

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This impacts the function setPWDbyBBS of the file /goform/setPWDbyBBS. Such manipulation of the argument hint leads to stack-based buffer overflow. ...

8.7CVSS6.5AI score0.00962EPSS
SaveExploits1References5
NVD
NVD
•added 2025/08/20 10:15 p.m.•18 views

CVE-2025-9250

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This impacts the function setPWDbyBBS of the file /goform/setPWDbyBBS. Such manipulation of the argument hint leads to stack-based buffer overflow. ...

9CVSS0.00962EPSS
SaveExploits1References5
OSV
OSV
•added 2025/08/20 9:15 p.m.•13 views

CVE-2025-9247

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The affected element is the function setVlan of the file /goform/setVlan. The manipulation of the argument vlanset leads to stack-based buffer...

8.7CVSS6.3AI score0.00962EPSS
SaveExploits1References5
Rows per page