103 matches found
CVE-2022-24321
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
Input validation
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
Code injection
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...
Input validation
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...
Design/Logic Flaw
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
CVE-2022-24321
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
CVE-2022-24321
CVE-2022-24321 is reported as a CWE-754 vulnerability causing Denial of Service to the Geo SCADA server when receiving malformed HTTP requests. Affected products include ClearSCADA (all versions) and EcoStruxure Geo SCADA Expert 2019 and 2020 (all versions). The connected documents confirm the ro...
CVE-2022-24320
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...
CVE-2022-24320
CVE-2022-24320 describes a vulnerability in the TLS/certificate handling that could enable a Man-in-the-Middle attack on communications between Geo SCADA clients and the Geo SCADA database server. Affected products include ClearSCADA (all versions) and EcoStruxure Geo SCADA Expert 2019 (all versi...
CVE-2022-24319
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
CVE-2022-24319
CVE-2022-24319 affects ClearSCADA (all versions) and EcoStruxure Geo SCADA Expert 2019/2020 (all versions). The underlying issue is CWE-295: improper certificate validation, enabling a potential Man‑in‑the‑Middle if communications between the client and Geo SCADA web server are intercepted. The a...
CVE-2022-24318
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...
CVE-2022-24318
CVE-2022-24318 affects ClearSCADA (All Versions) and EcoStruxure Geo SCADA Expert 2019/2020. The root cause is CWE-326: Inadequate Encryption Strength, causing non‑encrypted communication with the server when using outdated ViewX clients. The CVSS metrics updated show an attacker‑friendly network...
PT-2022-16605
Name of the Vulnerable Software and Affected Versions ClearSCADA All Versions EcoStruxure Geo SCADA Expert 2019 All Versions EcoStruxure Geo SCADA Expert 2020 All Versions Description A CWE-295: Improper Certificate Validation issue exists, allowing a Man-in-the-Middle attack when communications...
PT-2022-16602
Name of the Vulnerable Software and Affected Versions ClearSCADA affected versions not specified EcoStruxure Geo SCADA Expert 2019 affected versions not specified EcoStruxure Geo SCADA Expert 2020 affected versions not specified Description A vulnerability exists that could cause non-encrypted...
PT-2022-16603
Name of the Vulnerable Software and Affected Versions ClearSCADA All Versions EcoStruxure Geo SCADA Expert 2019 All Versions EcoStruxure Geo SCADA Expert 2020 All Versions Description A CWE-295: Improper Certificate Validation issue exists, allowing a Man-in-the-Middle attack when communications...
PT-2022-16606
Name of the Vulnerable Software and Affected Versions ClearSCADA versions all EcoStruxure Geo SCADA Expert 2019 versions all EcoStruxure Geo SCADA Expert 2020 versions all Description A vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed...
CVE-2022-24320: Improper Certificate Validation
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure G...
CVE-2022-24321: Improper Check for Unusual or Exceptional Conditions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...
CVE-2022-24318: Inadequate Encryption Strength
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo SCADA Expert...