Lucene search
+L

68 matches found

NVD
NVD
added 2019/07/03 4:15 p.m.23 views

CVE-2018-11423

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420...

7.8CVSS8.8AI score0.0136EPSS
SaveExploits0References1
NVD
NVD
added 2019/07/03 4:15 p.m.36 views

CVE-2018-11421

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

9.8CVSS9.3AI score0.00906EPSS
SaveExploits0References1
OSV
OSV
added 2019/07/03 4:15 p.m.13 views

CVE-2018-11421

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

9.8CVSS5.8AI score0.00906EPSS
SaveExploits0References1
NVD
NVD
added 2019/07/03 4:15 p.m.24 views

CVE-2018-11420

There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423...

9.8CVSS7.8AI score0.0154EPSS
SaveExploits0References1
NVD
NVD
added 2019/07/03 4:15 p.m.28 views

CVE-2018-11422

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands including devi...

9.8CVSS9.5AI score0.01022EPSS
SaveExploits0References1
OSV
OSV
added 2019/07/03 4:15 p.m.12 views

CVE-2018-11422

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands including devi...

9.8CVSS5.8AI score0.01022EPSS
SaveExploits0References1
OSV
OSV
added 2019/07/03 4:15 p.m.12 views

CVE-2018-11423

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420...

7.5CVSS5.8AI score0.0136EPSS
SaveExploits0References1
Prion
Prion
added 2019/07/03 4:15 p.m.20 views

Authentication flaw

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands including devi...

7.5CVSS9.3AI score0.01022EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2019/07/03 4:15 p.m.22 views

Memory corruption

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420...

7.8CVSS8.7AI score0.0154EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2019/07/03 4:15 p.m.31 views

Design/Logic Flaw

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

5CVSS9.2AI score0.00906EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2019/07/03 4:15 p.m.28 views

Memory corruption

There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423...

7.5CVSS7.8AI score0.0154EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2019/07/03 3:25 p.m.71 views

CVE-2018-11420

CVE-2018-11420 affects the Moxa OnCell G3100-HSPA Series web interface, specifically version 1.5 Build 17042015. The vulnerability is described as memory corruption in the web interface. The associated records list a high-severity impact (CVSS v2 base score 7.5; CVSS v3 base score 9.8) with netwo...

9.8CVSS7.8AI score0.0154EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/07/03 3:25 p.m.41 views

CVE-2018-11420

There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423...

8.2AI score0.0154EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2019/07/03 3:24 p.m.48 views

CVE-2018-11421

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

9.3AI score0.00906EPSS
SaveExploits0References1
CVE
CVE
added 2019/07/03 3:24 p.m.69 views

CVE-2018-11421

The CVE-2018-11421 entry affects Moxa OnCell G3100-HSPA Series, specifically version 1.6 Build 17100315 and prior. The root cause is a proprietary monitoring protocol that provides no confidentiality, integrity, or authenticity protections, sending information in plain text. Impact stated across ...

9.8CVSS9.1AI score0.00906EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2019/07/03 3:23 p.m.78 views

CVE-2018-11422

CVE-2018-11422 affects Moxa OnCell G3100-HSPA Series (versions 1.6 Build 17100315 and earlier). The vulnerability arises from a proprietary configuration protocol that provides no confidentiality, integrity, or authenticity—info is sent in plain text and can be intercepted or modified. Commands s...

9.8CVSS9.3AI score0.01022EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/07/03 3:23 p.m.30 views

CVE-2018-11422

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands including devi...

9.5AI score0.01022EPSS
SaveExploits0References1
CVE
CVE
added 2019/07/03 3:22 p.m.67 views

CVE-2018-11423

CVE-2018-11423 affects the web interface of the Moxa OnCell G3100-HSPA Series (version 1.6 Build 17100315 and prior). The issue is described as memory corruption and is explicitly noted as a different vulnerability from CVE-2018-11420. Connected documents provide no additional technical details (...

7.8CVSS8.7AI score0.0136EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/07/03 3:22 p.m.44 views

CVE-2018-11423

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420...

8.2AI score0.0136EPSS
SaveExploits0References1
OSV
OSV
added 2019/07/03 3:15 p.m.11 views

CVE-2018-11426

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change...

9.8CVSS5.8AI score0.01841EPSS
SaveExploits0References1
Rows per page
Query Builder