43 matches found
Tenda FH1201 Function Code Execution
The vulnerability of the frmL7ProtForm/goform/L7Prot function in the Tenda FH1201 router’s microprogramming software is related to the execution of operations outside the buffer in memory when processing the page parameter. Exploiting this vulnerability allows a remote attacker to execute arbitra...
CVE-2025-7549
CVE-2025-7549 affects Tenda FH1201 (version 1.2.0.14(408)). The vulnerability resides in the frmL7ProtForm function of /goform/L7Prot, where improper validation of the input page parameter enables a stack-based buffer overflow. This can be triggered remotely and, per sources, the exploit has been...
CVE-2025-7549: Stack-based Buffer Overflow
A vulnerability was found in Tenda FH1201 1.2.0.14408 and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
Tenda FH451 security vulnerabilities
The Tenda FH451 is a router from the Chinese company Tenda. The Tenda FH451 version 1.0.0.9 suffers from a buffer overflow vulnerability, which originates from the function frmL7ProtForm parameter page in file /goform/L7Prot that fails to correctly validate the length of the input data, which can...
CVE-2025-7505: Stack-based Buffer Overflow
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the atta...
CVE-2023-37715
Tenda F1202 V1.0BRV1.2.0.20408, FH1202V1.2.0.19EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm...
CVE-2024-42979
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted POST request...
Tenda FH1206 security vulnerabilities
Tenda FH1206 is a dual-band wireless router from Tenda, designed for large homes with fiber optics. The Tenda FH1206 suffers from a buffer overflow vulnerability that originates from a buffer overflow vulnerability in the page parameter of the frmL7ProtForm function, which can be exploited by an...
CVE-2024-42979
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted POST request...
CVE-2024-42979: Out-of-bounds Write
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted POST request...
CVE-2024-42979
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted POST request...
PT-2024-30234
Name of the Vulnerable Software and Affected Versions Tenda FH1206 version 02.03.01.35 Description A stack overflow issue was discovered, allowing attackers to cause a Denial of Service DoS via a crafted POST request. The issue is related to the page parameter in the frmL7ProtForm function...
CVE-2024-42979
CVE-2024-42979 concerns Tenda FH1206 (v02.03.01.35) with a stack overflow in the frmL7ProtForm function triggered by the page parameter. The vulnerability allows a crafted POST request to cause a Denial of Service. Multiple sources (NVD, Red Hat, CNVD/CNNVD mirrors) corroborate the issue; no publ...
Tenda F1202 FH1202 frmL7ProtForm Buffer Overflow
The vulnerability of the frmL7ProtForm function in the microprogramming software for Tenda F1202 and FH1202 is related to buffer overflow during the processing of the page parameter. Exploiting this vulnerability can allow an attacker to compromise the confidentiality, integrity, and accessibilit...
CVE-2024-3881
A vulnerability was found in Tenda W30E 1.0.1.25633 and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
CVE-2024-3881 Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow
A vulnerability was found in Tenda W30E 1.0.1.25633 and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been...
PT-2024-3768 · Tenda · Tenda W30E
Name of the Vulnerable Software and Affected Versions: Tenda W30E version 1.0.1.25633 Description: The issue is related to a stack-based buffer overflow in the frmL7PlotForm function of the file /goform/frmL7ProtForm. This can be exploited by manipulating the page argument, allowing a remote...
CVE-2023-37715
Tenda F1202 V1.0BRV1.2.0.20408, FH1202V1.2.0.19EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm...
CVE-2023-37715
Tenda F1202 V1.0BRV1.2.0.20408, FH1202V1.2.0.19EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm...
CVE-2023-37715: Out-of-bounds Write
Tenda F1202 V1.0BRV1.2.0.20408, FH1202V1.2.0.19EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm...