Cross site scripting
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting XSS due to improper input sanitization. An authenticated remote attacker can execute arbitrary JavaScript code in the web management interface. A successful exploit could allow the...
Command injection
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST parameter in the res.php endpoint. A successful exploit could allow th...
Design/Logic Flaw
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and...
CVE-2022-37060
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files...
CVE-2022-37060
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files...
Directory traversal
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files...
CVE-2022-37063
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting XSS due to improper input sanitization. An authenticated remote attacker can execute arbitrary JavaScript code in the web management interface. A successful exploit could allow the...
CVE-2022-37063
The connected sources confirm CVE-2022-37063 affects Teledyne FLIR AX8 thermal sensor cameras up to version 1.46.16, due to improper input sanitization that enables authenticated remote XSS in the web management interface. Successful exploits can execute arbitrary JavaScript in the victim’s brows...
CVE-2022-37062
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and...
CVE-2022-37062
The CVE-2022-37062 issue affects Teledyne FLIR AX8 thermal sensor cameras version up to and including 1.46.16, due to an insecure design from improper directory access restriction that allows an unauthenticated remote attacker to request a URI containing the path to the SQLite users database and ...
CVE-2022-37061
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST parameter in the res.php endpoint. A successful exploit could allow th...
PT-2022-23778 · Flir · Flir Ax8
Name of the Vulnerable Software and Affected Versions: FLIR AX8 thermal sensor cameras version up to and including 1.46.16 Description: The issue is due to an improper directory access restriction, allowing an unauthenticated, remote attacker to exploit it by sending a URI that contains the path ...
Teledyne FLIR AX8 访问控制错误漏洞
Teledyne FLIR AX8 is a series of thermal surveillance cameras from Teledyne FLIR USA. An access control error vulnerability exists in Teledyne FLIR AX8 versions 1.46.16 and earlier, which stems from improperly restricted directory access allowing an unauthenticated, remote attacker to obtain a...
PT-2022-23779 · Flir · Flir Ax8
Name of the Vulnerable Software and Affected Versions: FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 Description: The issue is due to improper input sanitization, allowing an authenticated remote attacker to execute arbitrary JavaScript code in the web management interface...
PT-2022-23776 · Flir · Flir Ax8
Name of the Vulnerable Software and Affected Versions: FLIR AX8 thermal sensor cameras version up to and including 1.46.16 Description: The issue is related to Directory Traversal due to improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contai...
Teledyne FLIR AX8 操作系统命令注入漏洞
Teledyne FLIR AX8 is a series of thermal surveillance cameras from Teledyne FLIR USA. Teledyne FLIR AX8 1.46.16 and earlier versions suffer from an operating system command injection vulnerability that originates from an attacker being able to use root privileges to execute arbitrary commands on...
PT-2022-23777 · Flir · Flir Ax8
Name of the Vulnerable Software and Affected Versions: FLIR AX8 thermal sensor cameras version up to and including 1.46.16 Description: The issue allows for Remote Command Injection, which can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST...
CVE-2022-37060
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files...
CVE-2022-37061
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST parameter in the res.php endpoint. A successful exploit could allow th...
Teledyne FLIR AX8 跨站脚本漏洞
Teledyne FLIR AX8 is a series of thermal surveillance cameras from the US-based Teledyne FLIR. A cross-site scripting vulnerability exists in Teledyne FLIR AX8 versions 1.46.16 and earlier, which stems from its improper sanitization of inputs that allows an authenticated, remote attacker to execu...