57850 matches found
EUVD-2025-208113
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicio...
EUVD-2026-8650
Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200...
Exploit for Out-of-bounds Write in Netapp C400_Firmware
No d...
CVE-2026-27846
Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to the network to gain access to sensitive information, including the password for admin access to the web interface and the Wi-Fi passwords.This issue affects...
CVE-2025-1242
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicio...
CVE-2026-27849 Missing neutralization in Linksys MR9600, Linksys MX4200
Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which is normally used for configuring devices inside the mesh network. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200...
CVE-2026-27517
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior reflect unsanitized user input in the web interface, allowing an attacker to inject and execute arbitrary JavaScript in the context of an authenticated user...
CVE-2026-27518
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior lack CSRF protections for state-changing actions in the administrative interface. An attacker can trick an authenticated administrator into performing unauthorized configuration changes...
CVE-2025-14577
Slican NCP/IPL/IPM/IPU devices are vulnerable to PHP Function Injection. An unauthenticated remote attacker is able to execute arbitrary PHP commands by sending specially crafted requests to /webcti/sessionajax.php endpoint. This issue was fixed in version 1.24.0190 Slican NCP and 6.61.0010 Slica...
CVE-2026-27520
Binardat 10G08-0800GSM network switch firmware versions prior to V300SP10260209 store a user password in a client-side cookie as a Base64-encoded value accessible via the web interface. Because Base64 is reversible and provides no confidentiality, an attacker who can access the cookie value can...
CVE-2026-23678
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior contain a command injection vulnerability in the traceroute diagnostic function of the affected device web management interface. By injecting the %1a character into the hostname parameter, an authenticated attacker wi...
CVE-2026-27516
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior expose user passwords in plaintext within the administrative interface and HTTP responses, allowing recovery of valid credentials...
CVE-2026-27507
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior contain hard-coded administrative credentials that cannot be changed by users. Knowledge of these credentials allows full administrative access to the device...
CVE-2025-1242
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicio...
CVE-2025-1242 Administrative Credentials Can Be Extracted Through Gardyn API Responses
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicio...
CVE-2025-1242 Administrative Credentials Can Be Extracted Through Gardyn API Responses
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicio...
CVE-2025-1242
CVE-2025-1242 affects Gardyn Home Kit via Gardyn IoT Hub. Root cause: hard-coded administrative credential iothubowner exposed across multiple vectors (API responses, mobile app, and device firmware), enabling unauthenticated full admin access to the hub and connected devices. Connected documents...
CVE-2026-27846
Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to the network to gain access to sensitive information, including the password for admin access to the web interface and the Wi-Fi passwords.This issue affects...
CVE-2026-3169
A security vulnerability has been detected in Tenda F453 1.0.0.3. This impacts the function fromSafeEmailFilter of the file /goform/SafeEmailFilter of the component httpd. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the attack is possible. The exploit ha...
CVE-2026-3166
A vulnerability was identified in Tenda F453 1.0.0.3. The affected element is the function fromRouteStatic of the file /goform/RouteStatic of the component httpd. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly availabl...