28 matches found
PT-2021-8030 · Mitsubishi · Melsec Iq-R Series Safety Cpu Modules R08/16/32/120Sfcpu +1
Name of the Vulnerable Software and Affected Versions: MELSEC iQ-R Series Safety CPU modules R08/16/32/120SFCPU firmware versions prior to 26 MELSEC iQ-R Series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions prior to 11 Description: The issue is related to the exposure of sensitiv...
HPESBST03940 rev.1 - HPE MSA 1040, HPE MSA 2040, HPE MSA 2042, HPE MSA 1050, HPE MSA 2050, and HPE MSA 2052 Multiple Remote Access Restriction Bypass
Potential Security Impact: Remote: Session Reuse SUPPORTED SOFTWARE VERSIONS: ONLY impacted versions are listed. HPE MSA 1040 SAN Storage GL225P001 and earlier HPE MSA 2040 SAN Storage GL225P001 and earlier HPE MSA 2042 SAN Storage GL225P001 and earlier HPE MSA 1050 SAN Storage VE270R001-01 and...
Security Bulletin: GNU C library (glibc) vulnerabilities affect IBM Security Network Active Bypass (CVE-2014-9761, CVE-2015-8778, CVE-2015-8779)
Summary GNU C library glibc vulnerabilities were found that affect IBM Security Network Active Bypass. Vulnerability Details CVEID: CVE-2014-9761 DESCRIPTION: GNU C Library glibc is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the nan function. By sending an...
PT-2018-4007 · D Link · D-Link Dir-868L +2
Name of the Vulnerable Software and Affected Versions: D-Link DIR-860L versions prior to DIR860LA1 FW110b04 D-Link DIR-865L versions prior to DIR-865L REVA FIRMWARE PATCH 1.08.B01 D-Link DIR-868L versions prior to DIR868LA1 FW112b04 Description: The issue is related to improper input validation i...
Robotic appliance COCOROBO vulnerable to session management
Overview Robotic appliance COCOROBO provided by Sharp Corporation is a robot with cleaning function. Robotic appliance COCOROBO contains a vulnerability in session management CWE-639. Kiyotaka ATSUMI of IoT Technology Laboratory, Cyber Grid Japan, LAC Co., Ltd. reported this vulnerability to IPA...
PT-2015-1513
Name of the Vulnerable Software and Affected Versions Firmware variant PROFINET IO for EN100 Ethernet module versions prior to V1.04.01 Firmware variant Modbus TCP for EN100 Ethernet module versions prior to V1.11.00 Firmware variant DNP3 TCP for EN100 Ethernet module versions prior to V1.03...
PT-2014-07: Sensitive Information Disclosure in Solar-Log
The specialists of the Positive Research center have detected a Sensitive Information Disclosure vulnerability in Solar-Log. CGI scripts used for backup and restore system data and configuration are not protected with password even if local authentication is enabled and could be accessed by an...
PT-2013-86: Denial of Service in Siemens SIMATIC S7-1500 CPU PLC
The specialists of the Positive Research center have detected a Denial of Service vulnerability in Siemens SIMATIC S7-1500 CPU PLC. Specially crafted Profinet packets sent to the affected device might cause the device to go into defect mode. A cold restart is required to recover the system. The...