6496 matches found
CVE-2022-26074
Incomplete cleanup in a firmware subsystem for IntelR SPS before versions SPSE304.08.04.330.0 and SPSE304.01.04.530.0 may allow a privileged user to potentially enable denial of service via local access...
CVE-2022-35273
OS command injection vulnerability in GUI setting page of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote authenticated attacker to execute an arbitrary OS command...
CVE-2019-18929
Western Digital My Cloud EX2 Ultra firmware 2.31.183 allows web users including guest accounts to remotely execute arbitrary code via a downloadmgr.cgi stack-based buffer overflow...
CVE-2019-18831
Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate...
CVE-2019-18238
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account...
CVE-2019-18931
Western Digital My Cloud EX2 Ultra firmware 2.31.195 allows a Buffer Overflow with Extended Instruction Pointer EIP control via crafted GET/POST parameters...
CVE-2019-11094
Insufficient input validation in system firmware for Intel R NUC Kit may allow an authenticated user to potentially enable escalation of privilege, denial of service, and/or information disclosure via local access...
CVE-2019-11128
Insufficient input validation in system firmware for IntelR NUC Kit may allow a privileged user to potentially enable escalation of privilege, denial of service and/or information disclosure via local access...
CVE-2019-11327
An issue was discovered on Topcon Positioning Net-G5 GNSS Receiver devices with firmware 5.2.2. The web interface of the product has a local file inclusion vulnerability. An attacker with administrative privileges can craft a special URL to read arbitrary files from the device's files system...
CVE-2020-7800
The Synergy Systems & Solutions SSS HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Improper Check for Unusual or Exceptional Conditions CWE-754 vulnerability. The affected product is vulnerable to specially crafted TCP packets, which can cause the device to shut down or reboot a...
CVE-2020-7512
A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 Firmware version 1.5.2 and older which could allow an attacker to exploit the component...
CVE-2020-7505
A CWE-494 Download of Code Without Integrity Check vulnerability exists in Easergy T300 Firmware version 1.5.2 and older which could allow an attacker to inject data with dangerous content into the firmware and execute arbitrary code on the system...
CVE-2020-7802
The Synergy Systems & Solutions SSS HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions CWE-276 vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SN...
CVE-2020-7509
A CWE-269: Improper privilege management write vulnerability exists in Easergy T300 Firmware version 1.5.2 and older which could allow an attacker to elevate their privileges and delete files...
CVE-2020-7506
A CWE-200: Information Exposure vulnerability exists in Easergy T300, Firmware V1.5.2 and prior, which could allow an attacker to pack or unpack the archive with the firmware for the controller and modules using the usual tar archiver resulting in an information exposure...
CVE-2020-7513
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 Firmware version 1.5.2 and older which could allow an attacker to intercept traffic and read configuration data...
CVE-2020-7135
A potential security vulnerability has been identified in the disk drive firmware installers named Supplemental Update / Online ROM Flash Component on HPE servers running Linux. The vulnerable software is included in the HPE Service Pack for ProLiant SPP releases 2018.06.0, 2018.09.0, and...
CVE-2020-12336
Insecure default variable initialization in firmware for some IntelR NUCs may allow an authenticated user to potentially enable escalation of privilege via local access...
CVE-2020-12042
Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access...
CVE-2020-12374
Buffer overflow in the BMC firmware for some IntelR Server Boards, Server Systems and Compute Modules before version 2.47 may allow a privileged user to potentially enable escalation of privilege via local access...