4332 matches found
EUVD-2025-198804
A firmware downgrade vulnerability exists in the OTA Update functionality of GL-Inet GL-AXT1800 4.7.0. A specially crafted .tar file can lead to a firmware downgrade. An attacker can perform a man-in-the-middle attack to trigger this vulnerability...
CVE-2025-65222
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the rebootTime parameter of /goform/SetSysAutoRebbotCfg...
CVE-2025-60738
An issue in Ilevia EVE X1 Server Firmware Version v4.7.18.0.eden and before Logic Version v6.00 - 20250721 and before allows a remote attacker to execute arbitrary code via the ping.php component does not perform secure filtering on IP parameters...
CVE-2025-65226
Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the deviceId parameter in /goform/saveParentControlInfo...
PT-2025-47580
An issue in Ilevia EVE X1 Server Firmware Version v4.7.18.0.eden and before Logic Version v6.00 - 2025 07 21 and before allows a remote attacker to execute arbitrary code via the ping.php component does not perform secure filtering on IP parameters...
PT-2025-47631
Name of the Vulnerable Software and Affected Versions FS Inc S3150-8T2F 8-Port Gigabit Ethernet L2+ Switch versions prior to 2.2.0D Build 135103 Description The FS Inc S3150-8T2F 8-Port Gigabit Ethernet L2+ Switch transmits cookies containing usernames and passwords in cleartext using base64...
CVE-2025-60737
Cross Site Scripting vulnerability in Ilevia EVE X1 Server Firmware Version= 4.7.18.0.eden:Logic Version=6.00 - 20250721 allows a remote attacker to execute arbitrary code via the /index.php component...
CVE-2025-60738
An issue in Ilevia EVE X1 Server Firmware Version v4.7.18.0.eden and before Logic Version v6.00 - 20250721 and before allows a remote attacker to execute arbitrary code via the ping.php component does not perform secure filtering on IP parameters...
EUVD-2025-198312
Cross Site Scripting vulnerability in Ilevia EVE X1 Server Firmware Version= 4.7.18.0.eden:Logic Version=6.00 - 20250721 allows a remote attacker to execute arbitrary code via the /index.php component...
PT-2025-47592
Cross Site Scripting vulnerability in Ilevia EVE X1 Server Firmware Version= 4.7.18.0.eden:Logic Version=6.00 - 2025 07 21 allows a remote attacker to execute arbitrary code via the /index.php component...
CVE-2025-65220
Tenda AC21 V16.03.08.16 is affected by a Buffer Overflow in /goform/SetVirtualServerCfg via the list parameter. The issue, described across multiple sources (NVD/CNVD/RH/ others), states input length validation failure can cause a denial of service. Affected device: Tenda AC21 dual‑band router. C...
CVE-2025-63209
The ELCA Star Transmitter Remote Control firmware 1.25 for STAR150, BP1000, STAR300, STAR2000, STAR1000, STAR500, and possibly other models, contains an information disclosure vulnerability allowing unauthenticated attackers to retrieve admin credentials and system settings via an unprotected...
CVE-2025-63212
GatesAir Flexiva-LX devices on firmware 1.0.13 and 2.0, including models LX100, LX300, LX600, and LX1000, expose sensitive session identifiers sid in the publicly accessible log file located at /log/Flexiva%20LX.log. An unauthenticated attacker can retrieve valid session IDs and hijack sessions...
PT-2025-47492
Name of the Vulnerable Software and Affected Versions bridgetech probes VB220 IP Network Probe, VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD versions 6.5.0-9 Description An issue exists that allows attackers to gain sensitive...
CVE-2025-63211
Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint...
PT-2025-47493
Name of the Vulnerable Software and Affected Versions Dasan Switch DS2924 versions 1.01.18 and 1.02.00 Description An authentication bypass exists in the web based interface of Dasan Switch DS2924. Successful exploitation allows attackers to gain escalated privileges by storing specially crafted...
CVE-2025-63219
The ITEL ISO FM SFN Adapter firmware ISO2 2.0.0.0, WebServer 2.0 is vulnerable to session hijacking due to improper session management on the /home.html endpoint. An attacker can access an active session without authentication, allowing them to control the device, modify configurations, and...
CVE-2025-63213
The QVidium Opera11 device firmware version 2.9.0-Ax4x-opera11 is vulnerable to Remote Code Execution RCE due to improper input validation on the /cgi-bin/netping.cgi endpoint. An attacker can exploit this vulnerability by sending a specially crafted GET request with a malicious parameter to inje...
PT-2025-47460
Name of the Vulnerable Software and Affected Versions ITEL ISO FM SFN Adapter versions ISO2 2.0.0.0 and WebServer 2.0 Description The ITEL ISO FM SFN Adapter is susceptible to session hijacking because of inadequate session management on the /home.html endpoint. An attacker can gain access to an...
CVE-2025-6599
An uncontrolled resource consumption vulnerability in the web server of Zyxel DX3301-T0 firmware version 5.50ABVY.6.3C0 and earlier could allow an attacker to perform Slowloris‑style denial‑of‑service DoS attacks. Such attacks may temporarily block legitimate HTTP requests and partially disrupt...