4400 matches found
PT-2025-34214 · Tenda · Tenda Ac15
Name of the Vulnerable Software and Affected Versions: Tenda AC15 version 15.03.05.19 multi TD01 Description: The Tenda AC15 router firmware contains a stack overflow issue. This occurs through the list parameter within the fromSetIpMacBind function. Recommendations: Update to a newer version of...
CVE-2025-9252 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 DisablePasswordAlertRedirect stack-based overflow
A weakness has been identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function DisablePasswordAlertRedirect of the file /goform/DisablePasswordAlertRedirect. Executing manipulation...
CVE-2025-55482
Tenda AC6 V15.03.06.23multi is vulnerable to Buffer Overflow in the formSetCfm function...
CVE-2025-55499
Tenda AC6 V15.03.06.23multi was discovered to contain a buffer overflow via the ntpServer parameter in the fromSetSysTime function...
CVE-2025-30256
A denial of service vulnerability exists in the HTTP Header Parsing functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted series of HTTP requests can lead to a reboot. An attacker can send multiple network packets to trigger this vulnerability...
CVE-2025-24496
An information disclosure vulnerability exists in the /goform/getproductInfo functionality of Tenda AC6 V5.0 V02.03.01.110. Specially crafted network packets can lead to a disclosure of sensitive information. An attacker can send packets to trigger this vulnerability...
CVE-2025-30256
A denial of service vulnerability exists in the HTTP Header Parsing functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted series of HTTP requests can lead to a reboot. An attacker can send multiple network packets to trigger this vulnerability...
CVE-2025-32010
A stack-based buffer overflow vulnerability exists in the Cloud API functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted HTTP response can lead to arbitrary code execution. An attacker can send an HTTP response to trigger this vulnerability...
CVE-2025-55591
TOTOLINK-A3002R v4.0.0-B20230531.1404 was discovered to contain a command injection vulnerability in the devicemac parameter in the formMapDel endpoint...
CVE-2025-55587
TOTOLINK A3002R v4.0.0-B20230531.1404 was discovered to contain a buffer overflow in the hostname parameter at /boafrm/formMapDelDevice. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted input...
CVE-2025-55585
TOTOLINK A3002R v4.0.0-B20230531.1404 was discovered to contain an eval injection vulnerability via the eval function...
CVE-2025-55584
TOTOLINK A3002R v4.0.0-B20230531.1404 was discovered to contain insecure credentials for the telnet service and root account...
CVE-2025-55482
CVE-2025-55482 affects Tenda AC6 with firmware V15.03.06.23_multi. The vulnerability is a buffer overflow in the formSetCfm function, exposing potential denial of service. Connected sources confirm the affected device and function but do not provide a patch or fix details; one source notes no inf...
PT-2025-34055 · Tenda · Tenda Ac6
Name of the Vulnerable Software and Affected Versions: Tenda AC6 version V15.03.06.23 multi Description: The Tenda AC6 router firmware is susceptible to a buffer overflow in the formSetMacFilterCfg function. The issue is triggered through the macFilterType and deviceList parameters...
CVE-2025-55498
Tenda AC6 V15.03.06.23multi was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function...
PT-2025-34067 · Tenda · Tenda Ac6
Name of the Vulnerable Software and Affected Versions: Tenda AC6 version 15.03.06.23 multi Description: The Tenda AC6 version 15.03.06.23 multi contains a buffer overflow via the time parameter in the fromSetSysTime function. Recommendations: At the moment, there is no information about a newer...
PT-2025-34056 · Tenda · Tenda Ac6
Name of the Vulnerable Software and Affected Versions: Tenda AC6 version 15.03.06.23 multi Description: The Tenda AC6 router firmware contains a stack overflow vulnerability. This issue is triggered via the deviceName parameter within the saveParentControlInfo function. Recommendations: Update to...
CVE-2025-55499
Tenda AC6 V15.03.06.23multi was discovered to contain a buffer overflow via the ntpServer parameter in the fromSetSysTime function...
PT-2025-34058 · Tenda · Tenda Ac6
Name of the Vulnerable Software and Affected Versions: Tenda AC6 version 15.03.06.23 multi Description: The device contains a buffer overflow through the ntpServer parameter in the fromSetSysTime function. Recommendations: At the moment, there is no information about a newer version that contains...
CVE-2025-9146
A flaw has been found in Linksys E5600 1.1.0.26. The affected element is the function verifygemtekheader of the file checkFw.sh of the component Firmware Handler. Executing manipulation can lead to risky cryptographic algorithm. The attack may be launched remotely. The attack requires a high leve...