Thomson SpeedTouch 500 modems vulnerable to XSS
TITLE: Thomson SpeedTouch 500 series vulnerable to XSS CRITICAL: Less critical IMPACT: Cross Site Scripting SOFTWARE: SpeedTouch 5.3.2.6.0 DESCRIPTION: There consists a vulnerability in the SpeedTouch modems, which can be exploited by malicious people to conduct cross-site scripting attacks, and...
CVE-2006-0096
wan/sdla.c in Linux kernel 2.6.x before 2.6.11 and 2.4.x before 2.4.29 does not require the CAPSYSRAWIO privilege for an SDLA firmware upgrade, with unknown impact and local attack vectors. NOTE: further investigation suggests that this issue requires root privileges to exploit, since it is...
Code injection
wan/sdla.c in Linux kernel 2.6.x before 2.6.11 and 2.4.x before 2.4.29 does not require the CAPSYSRAWIO privilege for an SDLA firmware upgrade, with unknown impact and local attack vectors. NOTE: further investigation suggests that this issue requires root privileges to exploit, since it is...
Linksys WRT54G DoS Vulnerability
It is possible to freeze the remote web server by sending an empty GET request. SPDX-FileCopyrightText: 2003 Michel Arboi Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2005-2916
Linksys WRT54G 3.01.03, 3.03.6, 4.00.7, and possibly other versions before 4.20.7, does not verify user authentication until after an HTTP POST request has been processed, which allows remote attackers to 1 modify configuration using restore.cgi or 2 upload new firmware using upgrade.cgi...
iDEFENSE Security Advisory 09.13.05: Linksys WRT54G 'upgrade.cgi' Firmware Upload Design Error Vulnerability
Linksys WRT54G 'upgrade.cgi' Firmware Upload Design Error Vulnerability iDEFENSE Security Advisory 09.13.05 www.idefense.com/application/poi/display?id=307&type=vulnerabilities September 13, 2005 I. BACKGROUND The Linksys WRT54G is a combination wireless access point, switch and router. More...
Siemens SANTIS 50 Authentication Vulnerability
Secure Network - Security Research Advisory Vuln name: Siemens SANTIS 50 Authentication Vulnerability Systems affected: Siemens Santis 50 Wireless router firmware version: 4.2.8.0 Likely to be affected: Ericsson HN294dp Dynalink RTA300W Severity: medium risk Local/Remote: Remote limited to the LA...
enterasys.txt
Problem Description An undocumented account with a default password exists, additionally guest users can DoS the switch. 2. Tested systems The following versions were tested and found vulnerable: Vertical Horizon VH-2402S with firmware 02.05.00 Vertical Horizon VH-2402S with firmware 02.05.09.07...
Yamaha MusicCAST MCX-1000 wireless network interface operates in Access Point mode by default
Overview The Yamaha MusicCAST MCX-1000 server wireless networking interface is enabled by default, cannot be disabled, and operates in Access Point mode. A remote attacker could access the MusicCAST wireless network and potentially any other network connected to the MusicCAST. Description The...
CVE-2005-1827
The CVE-2005-1827 issue affects the D-Link DSL-504T, where an unauthenticated remote attacker can bypass authentication by sending a direct request to the firmwarecfg endpoint. This allows privilege escalation to perform actions such as upgrading firmware, restarting the router, or restoring a sa...
CVE-2005-1827
D-Link DSL-504T allows remote attackers to bypass authentication and gain privileges, such as upgrade firmware, restart the router or restore a saved configuration, via a direct request to firmwarecfg...
504T and now also 604T remote access.
Dear ZARAZA, the problem pointed out by Francesco Orro is completely different by the one i had. Yes, the file is the same, but if you continue reading, you can see what i just said: the two bugs are completely different. The one i've described can be used even if is not the first access to the...
PT-2005-2794 · D Link · D-Link Dsl-504T
Name of the Vulnerable Software and Affected Versions: D-Link DSL-504T affected versions not specified Description: The issue allows remote attackers to bypass authentication and gain privileges. This can be achieved by making a direct request to the "firmwarecfg" endpoint. As a result, attackers...
[Full-disclosure] [ISR] Zyxel Prestige 650R-31 Denial Of Service
|| || Infobyte Security Research || www.infobyte.com.ar || 04.08.2005 || .:: SUMMARY Prestige 650R-31 ADSL Router -CPU exausting handling malformed fragmented packets Affected ZyNOS FW v3.40KO.1 It is suspected that all previous versions of ZyNOS are vulnerable. .:: BACKGROUND Zyxel Prestige 600...
linksys-WET11_pass-reset.txt
================== =====Analysis===== ================== Cisco's Linksys WET11 ethernet bridge product is vulnerable to password resetting based on GET fields in a URL directed at the device. The change password utility provided on the device uses GET to send an obfuscated password as the argumen...
Multiple Symantec security appliances fail to properly filter port 53/udp traffic
Overview A vulnerability exists in multiple Symantec security appliances that could allow a remote attacker to bypass the firewall using a source port of 53/udp. Description Symantec's Firewall/VPN appliances and Gateway Security models include a number of services such as tftpd, snmpd, and isakm...
Symantec Firewall/VPN appliance vulnerable to DoS via UDP port scan
Overview A vulnerability in the Symantec Firewall/VPN appliance could allow an attacker to cause a denial-of-service condition. Description The Symantec Firewall/VPN appliance supports a number of services that utilize the UDP protocol including tftpd, snmpd, and isakmp. There is a vulnerability ...
[Full-Disclosure] 3COM 3crwe754g72-a Administration interface code injection (DHCP)
Title: 3COM 3crwe754g72-a Administration interface code injection Class: Design error Affects: 3com 3crwe754g72-a v 1.11 v 1.13 v 1.24 Id: cbsa-0001 Release Date: 2004-10-18 Author : Cyrille Barthelemy [email protected] -- 1. Introduction ------------------ 3Com 3crwe754g72-a is a bundle...
usr8003.txt
Hello. US Robotics Broadband Router 8003 is a small home/SOHO router which is configured using a HTML interface. This interface, as usual, asks for a password in order to let you view or change configuration parameters. But the password is checked first by a javascript function that just compares...
APC SmartSlot Web/SNMP Management Card Default Password
The remote APC Smartslot Web/SNMP Management card ships with a default username and password. An attacker can use this information to access the remote APC device with any username and the factory password 'TENmanUFactOryPOWER'. C Tenable Network Security, Inc. Refs: Subject: APC 9606 SmartSlot...