5002 matches found
CVE-2020-12046
Opto 22 SoftPAC Project (firmware update mechanism) vulnerability CVE-2020-12046 affects version 9.6 and earlier. Root cause: firmware update files are not verified by signatures, enabling an attacker to replace legitimate firmware files with malicious ones. Practical impact (as stated): arbitrar...
CVE-2020-12046
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files...
Emerson WirelessHART Gateway
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Emerson Equipment: Emerson WirelessHART Gateways 1410, 1420 and 1552WU Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could disable the...
Opto 22 SoftPAC Project
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Opto 22 Equipment: SoftPAC Project Vulnerabilities: External Control of File Name or Path, Improper Verification of Cryptographic Signature, Improper Access Control, Uncontrolled Search Path...
CVE-2020-10019
USB DFU has a potential buffer overflow where the requested length wLength is not checked against the buffer size. This could be used by a malicious USB host to exploit the buffer overflow. See NCC-ZEP-002 This issue affects: zephyrproject-rtos zephyr version 1.14.1 and later versions. version...
TP-LINK Cloud Cameras NCXXX SetEncryptKey Command Injection
Vulnerability title: TP-LINK Cloud Cameras NCXXX SetEncryptKey Command Injection Author: Pietro Oliva CVE: CVE-2020-12111 Vendor: TP-LINK Product: NC260, NC450 Affected version: NC260 %s/%08X" 0x00491734 lw a1, EncryptKeyparam ; Attacker controlled string 0x00491738 lw a2, -0x7fd4gp 0x0049173c no...
Multiple SHARP Android devices vulnerable to information disclosure
Overview Multiple SHARP Android devices contain an information disclosure vulnerability CWE-200. Impact Sensitive information of the device may be obtained by the other android application installed in the device. Solution Update the Firmware Update the firmware to the latest version according to...
JVN#93064451: Multiple SHARP Android devices vulnerable to information disclosure
Multiple SHARP Android devices contain an information disclosure vulnerability CWE-200. Impact Sensitive information of the device may be obtained by the other android application installed in the device. Solution Update the Firmware Update the firmware to the latest version according to the...
CVE-2019-20731
CVE-2019-20731 affects a broad set of NETGEAR routers and extenders (e.g., D6220, D6400, D7000v2, D8500, EX3700/3800/6000/6100/6120/6130/6150v1/6200/7000, R6250/6300v2/6400v2/6700/6900/7000/6900P/7000P/7100LG/7300DST/8000/7900P/8000P/8300/8500, WN2500RPv2, WNDR3400v3) prior to the fixed versions ...
PT-2020-6990 · Draytek · Draytek Vigor2960 +2
Name of the Vulnerable Software and Affected Versions: DrayTek Vigor3900, Vigor2960, and Vigor300B devices versions prior to 1.5.1 Description: The issue exists due to the lack of measures to neutralize special elements used in the operating system command. This allows a remote attacker to execut...
Windows 8.1 or Windows RT 8.1 restarts two times after it installs a firmware update
Windows 8.1 or Windows RT 8.1 restarts two times after it installs a firmware update Resolution To resolve this problem, install the update that is described in this article. Update information How to obtain this update Windows Update This update is available from Windows Update. Microsoft Downlo...
CVE-2020-6974
Honeywell Notifier Web Server NWS Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem...
CVE-2020-6974
Honeywell Notifier Web Server NWS Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem...
Path traversal
Honeywell Notifier Web Server NWS Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem...
CVE-2020-6974
Honeywell Notifier Web Server NWS Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem...
CVE-2020-6974
Honeywell Notifier Web Server NWS Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem...
CVE-2020-6974
The CVE-2020-6974 issue affects Honeywell Notifier Web Server (NWS) versions 3.50 and earlier, where a path traversal vulnerability can bypass access to restricted directories. Multiple sources corroborate the vulnerability and indicate a firmware update from Honeywell addresses the problem. CISA...
Moderate: Red Hat Security Advisory: kernel security and bug fix update
An update for kernel is now available for Red Hat Enterprise Linux 8. Red Hat Product Security has rated this update as having a security impact of Moderate. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity rating, is available for each vulnerability from the...
CVE-2020-8144
The UniFi Video Server v3.9.3 and prior for Windows 7/8/10 x64 web interface Firmware Update functionality, under certain circumstances, does not validate firmware download destinations to ensure they are within the intended destination directory tree. It accepts a request with a URL to firmware...
CVE-2020-8144
The UniFi Video Server v3.9.3 and prior for Windows 7/8/10 x64 web interface Firmware Update functionality, under certain circumstances, does not validate firmware download destinations to ensure they are within the intended destination directory tree. It accepts a request with a URL to firmware...