Lucene search
K

838 matches found

CVE
CVE
added 2021/03/18 5:55 p.m.49 views

CVE-2020-14516

Rockwell Automation FactoryTalk Services Platform (versions 6.10.00 and 6.11.00) is affected by CVE-2020-14516 due to incorrect SHA-256 password hashing. The underlying issue prevents proper hashing of user passwords, which could enable unauthenticated remote attackers to abuse the authentication...

10CVSS9.4AI score0.04095EPSS
Exploits0References1Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/03/02 12:0 a.m.3 views

The vulnerability of the CServerManager::HandleBrowseLoadIconStreamRequest function in the FactoryTalk Linx automation software allows a intruder to trigger a service failure.

The vulnerability of the CServerManager::HandleBrowseLoadIconStreamRequest function messaging.dll in the FactoryTalk Linx automation software is related to the unlimited distribution of resources. Exploiting this vulnerability could allow an attacker to cause a service failure by sending a...

5.5CVSS5.9AI score0.04776EPSS
Exploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/03/02 12:0 a.m.3 views

The vulnerability of the CFTLDManager::HandleRequest function in the RnaDaSvr.dll software of the FactoryTalk Linx automation system allows a intruder to trigger a service failure.

The vulnerability of the CFTLDManager::HandleRequest function in the FactoryTalk Linx automation system software is related to deficiencies in handling exceptional states. Exploiting this vulnerability can allow an attacker, operating remotely, to cause service failures...

7.8CVSS7.2AI score0.25219EPSS
Exploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/03/02 12:0 a.m.4 views

The vulnerability of the FactoryTalk Linx automation system’s software, related to deficiencies in handling exceptional states, allows a perpetrator to complete the RSLinxNG.exe process.

The vulnerability of the FactoryTalk Linx automation system’s software is related to deficiencies in handling exceptional states. Exploiting this vulnerability could allow a malicious actor to successfully execute the RSLinxNG.exe process by sending a specially crafted ConfigureItems message via...

7.8CVSS7.2AI score0.38828EPSS
Exploits0References3Affected Software1
ICS
ICS
added 2021/02/23 12:0 a.m.58 views

Rockwell Automation FactoryTalk Services Platform

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Services Vulnerability: Use of Password Hash with Insufficient Computational Effort 2. RISK EVALUATION Successful exploitation of this vulnerability...

10CVSS9.9AI score0.04095EPSS
Exploits0References5
ICS
ICS
added 2021/01/28 12:0 a.m.79 views

Rockwell Automation FactoryTalk Linx and FactoryTalk Services Platform

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Linx and FactoryTalk Services Platform Vulnerabilities: Classic Buffer overflow, Improper Check or Handling of Exceptional Conditions 2. RISK EVALUATION...

7.5CVSS7.6AI score0.38828EPSS
Exploits0References5
NVD
NVD
added 2020/12/29 4:15 p.m.17 views

CVE-2020-5806

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk...

5.5CVSS6AI score0.04776EPSS
Exploits0References1
OSV
OSV
added 2020/12/29 4:15 p.m.2 views

CVE-2020-5802

An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions ...

7.5CVSS7.1AI score0.38828EPSS
Exploits0References1
OSV
OSV
added 2020/12/29 4:15 p.m.3 views

CVE-2020-5806

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk...

5.5CVSS6.1AI score
Exploits0References1
OSV
OSV
added 2020/12/29 4:15 p.m.5 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.5CVSS7.2AI score0.33836EPSS
Exploits0References1
OSV
OSV
added 2020/12/29 4:15 p.m.3 views

CVE-2020-5801

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affect...

7.5CVSS7.1AI score0.25219EPSS
Exploits0References1
NVD
NVD
added 2020/12/29 4:15 p.m.25 views

CVE-2020-5801

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affect...

7.5CVSS7.5AI score0.25219EPSS
Exploits0References1
NVD
NVD
added 2020/12/29 4:15 p.m.21 views

CVE-2020-5802

An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions ...

7.5CVSS7.4AI score0.38828EPSS
Exploits0References1
NVD
NVD
added 2020/12/29 4:15 p.m.20 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.5CVSS7.4AI score0.33836EPSS
Exploits0References1
Prion
Prion
added 2020/12/29 4:15 p.m.24 views

Code injection

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

5CVSS7.4AI score0.33836EPSS
Exploits0References1Affected Software1
Prion
Prion
added 2020/12/29 4:15 p.m.16 views

Design/Logic Flaw

An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions ...

5CVSS7.4AI score0.38828EPSS
Exploits0References1Affected Software1
Prion
Prion
added 2020/12/29 4:15 p.m.18 views

Design/Logic Flaw

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk...

2.1CVSS6AI score0.04776EPSS
Exploits0References1Affected Software1
Prion
Prion
added 2020/12/29 4:15 p.m.18 views

Code injection

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affect...

5CVSS7.5AI score0.25219EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/12/29 3:18 p.m.27 views

CVE-2020-5807

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

7.4AI score0.33836EPSS
Exploits0References1
CVE
CVE
added 2020/12/29 3:18 p.m.52 views

CVE-2020-5807

Summary: CVE-2020-5807 affects Rockwell Automation’s FactoryTalk Diagnostics (and related components) where an unauthenticated remote actor can send data to RsvcHost.exe (TCP port 5241) to inject log entries. The attacker can craft long fields that trigger an unhandled wcscpy_s() exception when a...

7.5CVSS7.4AI score0.33836EPSS
Exploits0References1Affected Software1